Ventilator Data Extraction with a Video Display Image Capture and Processing System.

David B Wax1, Bryan Hill2, Matthew A Levin2.   

Abstract

Medical hardware and software device interoperability standards are not uniform. The result of this lack of standardization is that information available on clinical devices may not be readily or freely available for import into other systems for research, decision support, or other purposes. We developed a novel system to import discrete data from an anesthesia machine ventilator by capturing images of the graphical display screen and using image processing to extract the data with off-the-shelf hardware and open-source software. We were able to successfully capture and verify live ventilator data from anesthesia machines in multiple operating rooms and store the discrete data in a relational database at a substantially lower cost than vendor-sourced solutions.

Keywords:  Image processing; Information extraction; Systems integration

Mesh:

Year:  2017        PMID: 28526944     DOI: 10.1007/s10916-017-0751-2

Source DB:  PubMed          Journal:  J Med Syst        ISSN: 0148-5598            Impact factor:   4.460


  7 in total

1.  Individualized feedback of volatile agent use reduces fresh gas flow rate, but fails to favorably affect agent choice.

Authors:  S C Body; J Fanikos; D DePeiro; J H Philip; B S Segal
Journal:  Anesthesiology       Date:  1999-04       Impact factor: 7.892

2.  A real-time anesthesia record keeping system using video.

Authors:  J C Piepenbrink; J I Cullen; T J Stafford
Journal:  J Clin Eng       Date:  1990 Sep-Oct

3.  An audit of anaesthetic fresh-gas flow rates and volatile anaesthetic use in a teaching hospital.

Authors:  Ross Kennedy; Richard French
Journal:  N Z Med J       Date:  2003-05-16

Review 4.  Data, Big Data, and Metadata in Anesthesiology.

Authors:  Matthew A Levin; Jonathan P Wanderer; Jesse M Ehrenfeld
Journal:  Anesth Analg       Date:  2015-12       Impact factor: 5.108

5.  Changing patterns in anesthetic fresh gas flow rates over 5 years in a teaching hospital.

Authors:  R Ross Kennedy; Richard A French
Journal:  Anesth Analg       Date:  2008-05       Impact factor: 5.108

6.  "If I Had Some Duct Tape, I Could Fix That".

Authors:  Keith J Ruskin; Avery Tung
Journal:  Anesth Analg       Date:  2016-11       Impact factor: 5.108

7.  The Need to Apply Medical Device Informatics in Developing Standards for Safe Interoperable Medical Systems.

Authors:  Sandy Weininger; Michael B Jaffe; Julian M Goldman
Journal:  Anesth Analg       Date:  2017-01       Impact factor: 5.108

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.