Literature DB >> 27584685

The Need to Apply Medical Device Informatics in Developing Standards for Safe Interoperable Medical Systems.

Sandy Weininger1, Michael B Jaffe, Julian M Goldman.   

Abstract

Medical device and health information technology systems are increasingly interdependent with users demanding increased interoperability. Related safety standards must be developed taking into account these systems' perspective. In this article, we describe the current development of medical device standards and the need for these standards to address medical device informatics. Medical device information should be gathered from a broad range of clinical scenarios to lay the foundation for safe medical device interoperability. Five clinical examples show how medical device informatics principles, if applied in the development of medical device standards, could help facilitate the development of safe interoperable medical device systems. These examples illustrate the clinical implications of the failure to capture important signals and device attributes. We provide recommendations relating to the coordination between historically separate standards development groups, some of which focus on safety and effectiveness and others focus on health informatics. We identify the need for a shared understanding among stakeholders and describe organizational structures to promote cooperation such that device-to-device interactions and related safety information are considered during standards development.

Entities:  

Mesh:

Substances:

Year:  2017        PMID: 27584685      PMCID: PMC5010005          DOI: 10.1213/ANE.0000000000001386

Source DB:  PubMed          Journal:  Anesth Analg        ISSN: 0003-2999            Impact factor:   5.108


  14 in total

1.  Design of an x-ray / ventilator synchronization system in an integrated clinical environment.

Authors:  David Arney; Kunal Bhatia; Sanchit Bhatia; Michael Sutton; Tracy Rausch; Joel Karlinsky; Julian M Goldman
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2011

2.  An ontology-based approach facilitating unified querying of biosignals and patient records.

Authors:  Alexandra Kokkinaki; Ioanna Chouvarda; Nicos Maglaveras
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2008

3.  [Interpretation of YY/T 0841-2011 Medical electrical equipment--recurrent test and test after repair of medical electrical equipment standard].

Authors:  Jun He
Journal:  Zhongguo Yi Liao Qi Xie Za Zhi       Date:  2015-01

4.  The future of connectivity. Linking medical devices to the EHR creates unexpected consequences.

Authors:  Anthony J Montagno
Journal:  Trustee       Date:  2012 Nov-Dec

5.  Mechanism underlying accelerated arterial oxygen desaturation during recurrent apnea.

Authors:  Scott A Sands; Bradley A Edwards; Vanessa J Kelly; Elizabeth M Skuza; Malcolm R Davidson; Malcolm H Wilkinson; Philip J Berger
Journal:  Am J Respir Crit Care Med       Date:  2010-06-03       Impact factor: 21.405

6.  Blood flow limits and pulse oximeter signal detection.

Authors:  D Lawson; I Norley; G Korbon; R Loeb; J Ellis
Journal:  Anesthesiology       Date:  1987-10       Impact factor: 7.892

7.  Choice of oximeter affects apnea-hypopnea index.

Authors:  Subooha Zafar; Indu Ayappa; Robert G Norman; Ana C Krieger; Joyce A Walsleben; David M Rapoport
Journal:  Chest       Date:  2005-01       Impact factor: 9.410

8.  A model analysis of arterial oxygen desaturation during apnea in preterm infants.

Authors:  Scott A Sands; Bradley A Edwards; Vanessa J Kelly; Malcolm R Davidson; Malcolm H Wilkinson; Philip J Berger
Journal:  PLoS Comput Biol       Date:  2009-12-04       Impact factor: 4.475

9.  The relationship between bradycardia, apnea, and hypoxemia in preterm infants.

Authors:  C F Poets; V A Stebbens; M P Samuels; D P Southall
Journal:  Pediatr Res       Date:  1993-08       Impact factor: 3.756

Review 10.  Context Aware Middleware Architectures: Survey and Challenges.

Authors:  Xin Li; Martina Eckert; José-Fernán Martinez; Gregorio Rubio
Journal:  Sensors (Basel)       Date:  2015-08-20       Impact factor: 3.576

View more
  5 in total

1.  Ventilator Data Extraction with a Video Display Image Capture and Processing System.

Authors:  David B Wax; Bryan Hill; Matthew A Levin
Journal:  J Med Syst       Date:  2017-05-20       Impact factor: 4.460

2.  A Century of Technology in Anesthesia & Analgesia.

Authors:  Jane S Moon; Maxime Cannesson
Journal:  Anesth Analg       Date:  2022-07-15       Impact factor: 6.627

3.  The influence of electrocardiogram (ECG) filters on the heights of R and T waves in children.

Authors:  Jun Hirokawa; Takashi Hitosugi; Yoichiro Miki; Masanori Tsukamoto; Fumiyasu Yamasaki; Yoshifumi Kawakubo; Takeshi Yokoyama
Journal:  Sci Rep       Date:  2022-08-02       Impact factor: 4.996

Review 4.  Timing errors and temporal uncertainty in clinical databases-A narrative review.

Authors:  Andrew J Goodwin; Danny Eytan; William Dixon; Sebastian D Goodfellow; Zakary Doherty; Robert W Greer; Alistair McEwan; Mark Tracy; Peter C Laussen; Azadeh Assadi; Mjaye Mazwi
Journal:  Front Digit Health       Date:  2022-08-18

5.  Development and Validation of a Multi-Algorithm Analytic Platform to Detect Off-Target Mechanical Ventilation.

Authors:  Jason Y Adams; Monica K Lieng; Brooks T Kuhn; Greg B Rehm; Edward C Guo; Sandra L Taylor; Jean-Pierre Delplanque; Nicholas R Anderson
Journal:  Sci Rep       Date:  2017-11-03       Impact factor: 4.379

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.