Literature DB >> 10201691

Individualized feedback of volatile agent use reduces fresh gas flow rate, but fails to favorably affect agent choice.

S C Body1, J Fanikos, D DePeiro, J H Philip, B S Segal.   

Abstract

BACKGROUND: Cost reduction has become an important fiscal aim of many hospitals and anesthetic departments, despite its inherent limitations. Volatile anesthetic agents are some of the few drugs that are amenable to such treatment because fresh gas flow rate (FGFR) can be independent of patient volatile anesthetic agent requirement.
METHODS: FGFR and drug use were recorded at the temporal midpoint of 2,031 general anesthetics during a 2-month preintervention period. Staff and residents were provided with their preintervention individual mean FGFR, their peer group mean, and educational material regarding volatile agent costs and low-flow anesthesia. FGFR and drug use were remeasured over a 2-month period (postintervention) immediately after this information (N = 2,242) and again 5 months later (delayed follow-up), for a further 2-month period (N = 2,056).
RESULTS: For all cases, FGFR decreased from 2.4+/-1.1 to 1.8+/-1.0 l/min (26% reduction) after the intervention and increased to 1.9+/-1.1 l/min (5% increase of preintervention FGFR) at the time of delayed follow-up. Use of more expensive volatile agents (desflurane and sevoflurane) increased during the study period (P < 0.01). In a subgroup of 44 staff members with more than five cases in all study periods, 42 members decreased their mean FGFR after intervention. At delayed follow-up, 30 members had increased their FGFR above postintervention FGFR but below their initial FGFR. After accounting for other predictors of FGFR, the effectiveness of the intervention was significantly reduced at follow-up (28% reduction), but retained a significant effect compared to preintervention FGFR (19% reduction).
CONCLUSIONS: Although individual feedback and education regarding volatile agent use was effective at reducing FGFR, effectiveness was reduced without continued feedback. Use of more expensive volatile agents was not reduced by education regarding drug cost, and actually increased.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10201691     DOI: 10.1097/00000542-199904000-00033

Source DB:  PubMed          Journal:  Anesthesiology        ISSN: 0003-3022            Impact factor:   7.892


  10 in total

Review 1.  Cost considerations in the use of anaesthetic drugs.

Authors:  I Smith
Journal:  Pharmacoeconomics       Date:  2001       Impact factor: 4.981

2.  The effect of the perioperative blood transfusion and blood conservation in cardiac surgery Clinical Practice Guidelines of the Society of Thoracic Surgeons and the Society of Cardiovascular Anesthesiologists upon clinical practices.

Authors:  Donald S Likosky; Daniel C FitzGerald; Robert C Groom; Dwayne K Jones; Robert A Baker; Kenneth G Shann; C David Mazer; Bruce D Spiess; Simon C Body
Journal:  J Extra Corpor Technol       Date:  2010-06

3.  Ventilator Data Extraction with a Video Display Image Capture and Processing System.

Authors:  David B Wax; Bryan Hill; Matthew A Levin
Journal:  J Med Syst       Date:  2017-05-20       Impact factor: 4.460

4.  Automated gas control with the Maquet FLOW-i.

Authors:  Rik Carette; Andre M De Wolf; Jan F A Hendrickx
Journal:  J Clin Monit Comput       Date:  2015-06-14       Impact factor: 2.502

Review 5.  Real-time alerts and reminders using information systems.

Authors:  Jonathan P Wanderer; Warren S Sandberg; Jesse M Ehrenfeld
Journal:  Anesthesiol Clin       Date:  2011-07-21

6.  Total intravenous anaesthesia: is it worth the cost?

Authors:  Ian Smith
Journal:  CNS Drugs       Date:  2003       Impact factor: 5.749

7.  A survey on the use of low flow anaesthesia and the choice of inhalational anaesthetic agents among anaesthesiologists of India.

Authors:  Rajasree Omanakutty Amma; Subha Ravindran; Rachel Cherian Koshy; K M Jagathnath Krishna
Journal:  Indian J Anaesth       Date:  2016-10

8.  Low flow anesthesia and volatile anesthetic agents - Concerns.

Authors:  Rakesh Garg
Journal:  J Anaesthesiol Clin Pharmacol       Date:  2012-10

9.  Agent consumption with the Zeus® in the automated closed circuit anesthesia mode with O2/air mixtures.

Authors:  Sofie De Cooman; Jan F A Hendrickx; Philip John Peyton; Jean-Luc Demeere; Andre M De Wolf
Journal:  BMC Res Notes       Date:  2014-07-23

10.  Analyzing Volatile Anesthetic Consumption by Auditing Fresh Gas Flow: An Observational Study at an Academic Hospital.

Authors:  Luis Tollinche; KaySee Tan; Austin Han; Leslie Ojea; Cindy Yeoh
Journal:  Int J Anesth Anesth       Date:  2018-04-26
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.