Literature DB >> 12766784

An audit of anaesthetic fresh-gas flow rates and volatile anaesthetic use in a teaching hospital.

Ross Kennedy1, Richard French.   

Abstract

AIM: The large number of anaesthetics administered means that the total cost to a hospital of inhalational anaesthetic agent such as isoflurane or sevoflurane can be considerable. The total anaesthetic gas flow is a major determinant of the use of these agents. Modern anaesthetic machines and monitoring facilitate reduced gas flows, which can significantly reduce wastage of these anaesthetic agents. The purpose of this study was to audit gas flow rates and volatile anaesthetic use.
METHODS: We audited gas flows and choice of anaesthetic agent over two one-month periods in one theatre at Christchurch Hospital. Data were collected directly from the anaesthetic machine using a computer. The second study period was clearly advised and followed widespread discussion of results from the first study period.
RESULTS: Average fresh-gas flow was approximately 2 l/min (Month 1 = 2.0 l/min, Month 2 = 2.1 l/min). Use of the more expensive agent, sevoflurane, increased but gas flows with this agent decreased.
CONCLUSIONS: Given the low flows used, the small difference between study periods was not surprising. The gas flows recorded represent responsible use of anaesthetic agents and are at least as good as flows achieved in previous studies that employed various methods to encourage their reduction.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12766784

Source DB:  PubMed          Journal:  N Z Med J        ISSN: 0028-8446


  4 in total

1.  Ventilator Data Extraction with a Video Display Image Capture and Processing System.

Authors:  David B Wax; Bryan Hill; Matthew A Levin
Journal:  J Med Syst       Date:  2017-05-20       Impact factor: 4.460

2.  An observation from an online survey: is fresh gas flow used for sevoflurane and desflurane different from isoflurane based anesthesia?

Authors:  Habib Md Reazaul Karim; Mamta Sinha; Mayank Kumar; Monica Khetrapal; Rashmi Dubey
Journal:  Med Gas Res       Date:  2019 Jan-Mar

3.  Greenhouse gas reduction in anaesthesia practice: a departmental environmental strategy.

Authors:  Kerstin Wyssusek; Ka Lo Chan; Gerard Eames; Yasmin Whately
Journal:  BMJ Open Qual       Date:  2022-08

4.  Analyzing Volatile Anesthetic Consumption by Auditing Fresh Gas Flow: An Observational Study at an Academic Hospital.

Authors:  Luis Tollinche; KaySee Tan; Austin Han; Leslie Ojea; Cindy Yeoh
Journal:  Int J Anesth Anesth       Date:  2018-04-26
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.