The comparative accuracy of the ROSA stereotactic robot across a wide range of clinical applications and registration techniques.

Nicholas J Brandmeir1, Sandip Savaliya2, Pratik Rohatgi2, Michael Sather2.   

Abstract

Robot-assisted stereotactic neurosurgery is an emerging technology with a growing range of applications. The ROSA system is a robotic stereotactic system that has been shown to be accurate in laboratory studies and large case series. The goal of this study was to examine the accuracy of the ROSA across different registration methods as well as different clinical applications. Sixteen patients with one hundred and seventeen stereotactic trajectories were examined. Accuracy was compared by measuring the distance between the trajectory target and the actual termination of the device as determined by imaging. Entry error and angular deviation were also measured. Variables included bone fiducials vs. laser facial scanning, the clinical indication for stereotactic surgery, and the effect of lead deflection on accuracy. Bone fiducials did not offer an accuracy benefit over laser facial scanning (mean target error 4.5-3.9 mm, p = 0.34) in these clinical scenarios. Laser interstitial thermal therapy, responsive neurostimulation, and stereo electroencephalography were equally accurate when placed by the ROSA (mean target error 4.4-4.3-4.0 mm, respectively, p = 0.69). Deflection did not affect lead accuracy (mean target error 4.4-3.9 mm, p = 0.11). Similar results are seen for entry error and angular deviation. ROSA is a highly accurate stereotactic system. Laser facial scanning provides the same accuracy as bone fiducials in these stereotactic applications. The ROSA is equally accurate across a wide spectrum of applications. The ROSA is effective at limiting lead deflection, and when it does occur, it does not impact target accuracy in a significant way.

Entities:  

Keywords:  Accuracy; Fiducial; Frameless; Neuronavigation; ROSA; Robot; Stereotactic

Mesh:

Year:  2017        PMID: 28484885     DOI: 10.1007/s11701-017-0712-2

Source DB:  PubMed          Journal:  J Robot Surg        ISSN: 1863-2483


  18 in total

1.  Contribution of low-dose CT-scan protocols to the total positioning error in computer-assisted surgery.

Authors:  H Husstedt; R Heermann; H Becker
Journal:  Comput Aided Surg       Date:  1999

2.  Quantification of true in vivo (application) accuracy in cranial image-guided surgery: influence of mode of patient registration.

Authors:  Christopher R Mascott; Jean-Christophe Sol; Philippe Bousquet; Jacques Lagarrigue; Yves Lazorthes; Valérie Lauwers-Cances
Journal:  Neurosurgery       Date:  2006-07       Impact factor: 4.654

3.  A decade of emerging indications: deep brain stimulation in the United States.

Authors:  Brett E Youngerman; Andrew K Chan; Charles B Mikell; Guy M McKhann; Sameer A Sheth
Journal:  J Neurosurg       Date:  2016-01-01       Impact factor: 5.115

4.  AAV2-GAD gene therapy for advanced Parkinson's disease: a double-blind, sham-surgery controlled, randomised trial.

Authors:  Peter A LeWitt; Ali R Rezai; Maureen A Leehey; Steven G Ojemann; Alice W Flaherty; Emad N Eskandar; Sandra K Kostyk; Karen Thomas; Atom Sarkar; Mustafa S Siddiqui; Stephen B Tatter; Jason M Schwalb; Kathleen L Poston; Jaimie M Henderson; Roger M Kurlan; Irene H Richard; Lori Van Meter; Christine V Sapan; Matthew J During; Michael G Kaplitt; Andrew Feigin
Journal:  Lancet Neurol       Date:  2011-04       Impact factor: 44.182

5.  MR-guided stereotactic laser ablation of epileptogenic foci in children.

Authors:  Daniel J Curry; Ashok Gowda; Roger J McNichols; Angus A Wilfong
Journal:  Epilepsy Behav       Date:  2012-06-09       Impact factor: 2.937

6.  Stereotactic robot-assisted MRI-guided laser thermal ablation of radiation necrosis in the posterior cranial fossa: technical note.

Authors:  Alvin Y Chan; Diem Kieu T Tran; Amandip S Gill; Frank P K Hsu; Sumeet Vadera
Journal:  Neurosurg Focus       Date:  2016-10       Impact factor: 4.047

7.  Error assessment during "image guided" and "imaging interactive" stereotactic surgery.

Authors:  H J Nauta
Journal:  Comput Med Imaging Graph       Date:  1994 Jul-Aug       Impact factor: 4.790

8.  Technique, Results, and Complications Related to Robot-Assisted Stereoelectroencephalography.

Authors:  Jorge González-Martínez; Juan Bulacio; Susan Thompson; John Gale; Saksith Smithason; Imad Najm; William Bingaman
Journal:  Neurosurgery       Date:  2016-02       Impact factor: 4.654

9.  Frameless Stereotactic Robot-Assisted Subthalamic Nucleus Deep Brain Stimulation: Case Report.

Authors:  Sumeet Vadera; Alvin Chan; Thomas Lo; Amandip Gill; Anna Morenkova; Nicolas M Phielipp; Neal Hermanowicz; Frank P K Hsu
Journal:  World Neurosurg       Date:  2015-11-14       Impact factor: 2.104

10.  Robot Assisted Stereotactic Laser Ablation for a Radiosurgery Resistant Hypothalamic Hamartoma.

Authors:  Nicholas Brandmeir; Vinita Acharya; Michael Sather
Journal:  Cureus       Date:  2016-04-21
View more
  6 in total

1.  Stereotactic accuracy must be as high as possible in stereoelectroencephalography procedures.

Authors:  Francesco Cardinale; Michele Rizzi
Journal:  J Robot Surg       Date:  2017-06-26

2.  Author response to: Stereotactic accuracy must be as high as possible in stereoelectroencephalography procedures.

Authors:  Nicholas J Brandmeir; Michael Sather
Journal:  J Robot Surg       Date:  2017-08-31

3.  Robotic drill guide positioning using known-component 3D-2D image registration.

Authors:  Thomas Yi; Vignesh Ramchandran; Jeffrey H Siewerdsen; Ali Uneri
Journal:  J Med Imaging (Bellingham)       Date:  2018-02-06

4.  Fluoroscopic Guidance of a Surgical Robot: Pre-clinical Evaluation in Pelvic Guidewire Placement.

Authors:  R C Vijayan; R Han; P Wu; N M Sheth; P Vagdargi; S Vogt; G Kleinszig; G M Osgood; J H Siewerdsen; A Uneri
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2021-02-25

5.  Development of a fluoroscopically guided robotic assistant for instrument placement in pelvic trauma surgery.

Authors:  Rohan C Vijayan; Runze Han; Pengwei Wu; Niral M Sheth; Michael D Ketcha; Prasad Vagdargi; Sebastian Vogt; Gerhard Kleinszig; Greg M Osgood; Jeffrey H Siewerdsen; Ali Uneri
Journal:  J Med Imaging (Bellingham)       Date:  2021-06-09

6.  Accuracy of Robotic and Frame-Based Stereotactic Neurosurgery in a Phantom Model.

Authors:  Andrea Spyrantis; Tirza Woebbecke; Daniel Rueß; Anne Constantinescu; Andreas Gierich; Klaus Luyken; Veerle Visser-Vandewalle; Eva Herrmann; Florian Gessler; Marcus Czabanka; Harald Treuer; Maximilian Ruge; Thomas M Freiman
Journal:  Front Neurorobot       Date:  2022-03-25       Impact factor: 3.493

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.