Literature DB >> 28462467

The effect of CT-based attenuation correction on the automatic perfusion score of myocardial perfusion imaging using a dedicated cardiac solid-state CZT SPECT/CT.

John A Kennedy1,2, Yafim Brodov3, Adam L Weinstein4, Ora Israel3,4, Alex Frenkel3.   

Abstract

BACKGROUND: Data regarding cardiac cadmium-zinc-telluride (CZT)-specific augmented databases and their impact on CT-based attenuation correction (AC) perfusion scores in myocardial perfusion imaging (MPI) were obtained on a multiple-pinhole CZT SPECT/CT. METHODS AND
RESULTS: Summed stress (SSS) and rest scores (SRS) were measured using automated software in three independent patient groups: group 1 (n = 80) underwent MPI on both CZT and conventional sodium iodide (NaI) devices, group 2 (n = 80) with low coronary artery disease likelihood and normal MPI provided reference CZT databases; and group 3 (n = 152) served to compare AC and non-AC (NAC) scores on CZT. Group 1 CZT and NaI scores gave a significant 1:1 linear correlation for CZT scores referenced to the custom database vs NaI scores referenced to the default database, but these were not concordant when CZT scores were referenced to the default database. AC significantly decreased average SSS and SRS in men vs NAC, 4.29 ± 6.30 vs 5.37 ± 7.26 (P < 0.001) and 2.37 ± 4.72 vs 3.13 ± 5.85 (P < 0.001), but not in women, 2.28 ± 3.42 vs 2.28 ± 3.08 (p NS) and 0.46 ± 1.51 vs 0.61 ± 1.86, (p NS), respectively.
CONCLUSIONS: Specifically designed databases for solid-state CZT cardiac SPECT provide accurate quantitation of perfusion scores concordant with those previously validated for conventional SPECT. AC and NAC CZT scores differed significantly, especially in men.

Entities:  

Keywords:  Instrumentation: SPECT; cadmium-zinc-telluride; myocardial perfusion imaging: SPECT; summed stress score; ultrafast cardiac gamma camera

Year:  2017        PMID: 28462467     DOI: 10.1007/s12350-017-0905-0

Source DB:  PubMed          Journal:  J Nucl Cardiol        ISSN: 1071-3581            Impact factor:   5.952


  27 in total

1.  Accelerated image reconstruction using ordered subsets of projection data.

Authors:  H M Hudson; R S Larkin
Journal:  IEEE Trans Med Imaging       Date:  1994       Impact factor: 10.048

2.  Comparison of three commercially available softwares for measuring left ventricular perfusion and function by gated SPECT myocardial perfusion imaging.

Authors:  Sameer Ather; Fahad Iqbal; John Gulotta; Wael Aljaroudi; Jaekyeong Heo; Ami E Iskandrian; Fadi G Hage
Journal:  J Nucl Cardiol       Date:  2014-04-09       Impact factor: 5.952

3.  A performance comparison of novel cadmium-zinc-telluride camera and conventional SPECT/CT using anthropomorphic torso phantom and water bags to simulate soft tissue and breast attenuation.

Authors:  Chia-Ju Liu; Ju-Shin Cheng; Yi-Chieh Chen; Yih-Hwen Huang; Ruoh-Fang Yen
Journal:  Ann Nucl Med       Date:  2015-01-28       Impact factor: 2.668

4.  Impact of attenuation correction and gated acquisition in SPECT myocardial perfusion imaging: results of the multicentre SPAG (SPECT Attenuation Correction vs Gated) study.

Authors:  Dario Genovesi; Assuero Giorgetti; Alessia Gimelli; Annette Kusch; Irene D'Aragona Tagliavia; Mirta Casagranda; Giorgio Cannizzaro; Raffaele Giubbini; Francesco Bertagna; Giorgio Fagioli; Massimiliano Rossi; Annadina Romeo; Pietro Bertolaccini; Rita Bonini; Paolo Marzullo
Journal:  Eur J Nucl Med Mol Imaging       Date:  2011-06-09       Impact factor: 9.236

5.  Incremental prognostic value of myocardial perfusion single photon emission computed tomography for the prediction of cardiac death: differential stratification for risk of cardiac death and myocardial infarction.

Authors:  R Hachamovitch; D S Berman; L J Shaw; H Kiat; I Cohen; J A Cabico; J Friedman; G A Diamond
Journal:  Circulation       Date:  1998-02-17       Impact factor: 29.690

6.  A new algorithm for the quantitation of myocardial perfusion SPECT. I: technical principles and reproducibility.

Authors:  G Germano; P B Kavanagh; P Waechter; J Areeda; S Van Kriekinge; T Sharir; H C Lewin; D S Berman
Journal:  J Nucl Med       Date:  2000-04       Impact factor: 10.057

7.  Comparison of the diagnostic accuracies of very low stress-dose with standard-dose myocardial perfusion imaging: Automated quantification of one-day, stress-first SPECT using a CZT camera.

Authors:  Tali Sharir; Marina Pinskiy; Abraham Pardes; Arik Rochman; Vitali Prokhorov; Gil Kovalski; Konstantine Merzon; Andrzej Bojko; Boris Brodkin
Journal:  J Nucl Cardiol       Date:  2015-05-27       Impact factor: 5.952

8.  Importance of correct patient positioning in myocardial perfusion SPECT when using a CZT camera.

Authors:  Cecilia Hindorf; Jenny Oddstig; Fredrik Hedeer; Magnus J Hansson; Jonas Jögi; Henrik Engblom
Journal:  J Nucl Cardiol       Date:  2014-05-08       Impact factor: 5.952

9.  3D iteratively reconstructed spatial resolution map and sensitivity characterization of a dedicated cardiac SPECT camera.

Authors:  John A Kennedy; Ora Israel; Alex Frenkel
Journal:  J Nucl Cardiol       Date:  2014-01-16       Impact factor: 5.952

10.  High-efficiency SPECT MPI: comparison of automated quantification, visual interpretation, and coronary angiography.

Authors:  W Lane Duvall; Piotr J Slomka; Jim R Gerlach; Joseph M Sweeny; Usman Baber; Lori B Croft; Krista A Guma; Titus George; Milena J Henzlova
Journal:  J Nucl Cardiol       Date:  2013-06-05       Impact factor: 5.952

View more
  3 in total

1.  Diagnostic implications of CZT SPECT and impact of CT attenuation correction.

Authors:  Andrew Peters; Jeevan Kumar; Pravin V Patil
Journal:  J Nucl Cardiol       Date:  2017-06-23       Impact factor: 5.952

2.  Improved diagnostic accuracy of thallium-201 myocardial perfusion single-photon emission computed tomography with CT attenuation correction.

Authors:  Jei-Yie Huang; Ruoh-Fang Yen; Wen-Chung Lee; Chun-Kai Huang; Pei-Ying Hsu; Mei-Fang Cheng; Ching-Chu Lu; Yen-Hung Lin; Kuo-Liong Chien; Yen-Wen Wu
Journal:  J Nucl Cardiol       Date:  2018-02-26       Impact factor: 5.952

3.  Long-term prognostic value of computed tomography-based attenuation correction on thallium-201 myocardial perfusion imaging: A cohort study.

Authors:  Jei-Yie Huang; Ruoh-Fang Yen; Chun-Kai Huang; Chia-Ju Liu; Mei-Fang Cheng; Kuo-Liong Chien; Yen-Wen Wu
Journal:  PLoS One       Date:  2021-10-26       Impact factor: 3.240

  3 in total