Literature DB >> 23737160

High-efficiency SPECT MPI: comparison of automated quantification, visual interpretation, and coronary angiography.

W Lane Duvall1, Piotr J Slomka, Jim R Gerlach, Joseph M Sweeny, Usman Baber, Lori B Croft, Krista A Guma, Titus George, Milena J Henzlova.   

Abstract

BACKGROUND: Recently introduced high-efficiency (HE) SPECT cameras with solid-state CZT detectors have been shown to decrease imaging time and reduce radiation exposure to patients. An automated, computer-derived quantification of HE MPI has been shown to correlate well with coronary angiography on one HE SPECT camera system (D-SPECT), but has not been compared to visual interpretation on any of the HE SPECT platforms.
METHODS: Patients undergoing a clinically indicated Tc-99m sestamibi HE SPECT (GE Discovery 530c with supine and prone imaging) study over a 1-year period followed by a coronary angiogram within 2 months were included. Only patients with a history of CABG surgery were excluded. Both MPI studies and coronary angiograms were reinterpreted by blinded readers. One hundred and twenty two very low (risk of CAD < 5%) or low (risk of CAD < 10%) likelihood subjects with normal myocardial perfusion were used to create normal reference limits. Computer-derived quantification of the total perfusion deficit at stress and rest was obtained with QPS software. The visual and automated MPI quantification were compared to coronary angiography (≥70% luminal stenosis) by receiver operating curve (ROC) analysis.
RESULTS: Of the 3,111 patients who underwent HE SPECT over a 1-year period, 160 patients qualified for the correlation study (66% male, 52% with a history of CAD). The ROC area under the curve (AUC) was similar for both the automated and the visual interpretations using both supine only and combined supine and prone images (0.69-0.74). Using thresholds determined from sensitivity and specificity curves, the automated reads showed higher specificity (59%-67% vs 27%-60%) and lower sensitivity (71%-72% vs 79%-93%) than the visual reads. By including prone images sensitivity decreased slightly but specificity increased for both. By excluding patients with known CAD and cardiomyopathies, AUC and specificity increased for both techniques (0.72-0.82). The use of a difference score to evaluate ischemic burden resulted in lower sensitivities but higher specificities for both automated and visual quantification. There was good agreement between the visual interpretation and automated quantification in the entire cohort of 160 unselected consecutive patients (r = 0.70-0.81, P < .0001).
CONCLUSIONS: Automated and visual quantification of high-efficiency SPECT MPI with the GE Discovery camera provides similar overall diagnostic accuracy when compared to coronary angiography. There was good correlation between the two methods of assessment. Combined supine and prone stress imaging provided the best diagnostic accuracy.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23737160      PMCID: PMC3820488          DOI: 10.1007/s12350-013-9735-x

Source DB:  PubMed          Journal:  J Nucl Cardiol        ISSN: 1071-3581            Impact factor:   5.952


  28 in total

Review 1.  Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart. A statement for healthcare professionals from the Cardiac Imaging Committee of the Council on Clinical Cardiology of the American Heart Association.

Authors:  Manuel D Cerqueira; Neil J Weissman; Vasken Dilsizian; Alice K Jacobs; Sanjiv Kaul; Warren K Laskey; Dudley J Pennell; John A Rumberger; Thomas Ryan; Mario S Verani
Journal:  J Nucl Cardiol       Date:  2002 Mar-Apr       Impact factor: 5.952

2.  Reduced stress dose with rapid acquisition CZT SPECT MPI in a non-obese clinical population: comparison to coronary angiography.

Authors:  W Lane Duvall; Joseph M Sweeny; Lori B Croft; Eric Ginsberg; Krista A Guma; Milena J Henzlova
Journal:  J Nucl Cardiol       Date:  2011-12-07       Impact factor: 5.952

3.  Simplified normal limits and automated quantitative assessment for attenuation-corrected myocardial perfusion SPECT.

Authors:  Piotr J Slomka; Mathews B Fish; Santiago Lorenzo; Hidetaka Nishina; James Gerlach; Daniel S Berman; Guido Germano
Journal:  J Nucl Cardiol       Date:  2006-09       Impact factor: 5.952

4.  Stress protocols and tracers.

Authors:  Milena J Henzlova; Manuel D Cerqueira; John J Mahmarian; Siu-Sun Yao
Journal:  J Nucl Cardiol       Date:  2006-11       Impact factor: 5.952

5.  Myocardial perfusion and function single photon emission computed tomography.

Authors:  Christopher L Hansen; Richard A Goldstein; Daniel S Berman; Keith B Churchwell; C David Cooke; James R Corbett; S James Cullom; Seth T Dahlberg; James R Galt; Ravi K Garg; Gary V Heller; Mark C Hyun; Lynne L Johnson; April Mann; Benjamin D McCallister; Raymond Taillefer; R Parker Ward; John J Mahmarian
Journal:  J Nucl Cardiol       Date:  2006-11       Impact factor: 5.952

6.  Combined supine and prone quantitative myocardial perfusion SPECT: method development and clinical validation in patients with no known coronary artery disease.

Authors:  Hidetaka Nishina; Piotr J Slomka; Aiden Abidov; Shunichi Yoda; Cigdem Akincioglu; Xingping Kang; Ishac Cohen; Sean W Hayes; John D Friedman; Guido Germano; Daniel S Berman
Journal:  J Nucl Med       Date:  2006-01       Impact factor: 10.057

7.  ACCF/ASNC/ACR/AHA/ASE/SCCT/SCMR/SNM 2009 appropriate use criteria for cardiac radionuclide imaging: a report of the American College of Cardiology Foundation Appropriate Use Criteria Task Force, the American Society of Nuclear Cardiology, the American College of Radiology, the American Heart Association, the American Society of Echocardiography, the Society of Cardiovascular Computed Tomography, the Society for Cardiovascular Magnetic Resonance, and the Society of Nuclear Medicine.

Authors:  Robert C Hendel; Daniel S Berman; Marcelo F Di Carli; Paul A Heidenreich; Robert E Henkin; Patricia A Pellikka; Gerald M Pohost; Kim A Williams
Journal:  Circulation       Date:  2009-05-18       Impact factor: 29.690

Review 8.  Advances in technical aspects of myocardial perfusion SPECT imaging.

Authors:  Piotr J Slomka; James A Patton; Daniel S Berman; Guido Germano
Journal:  J Nucl Cardiol       Date:  2009-02-26       Impact factor: 5.952

9.  Combined quantitative supine-prone myocardial perfusion SPECT improves detection of coronary artery disease and normalcy rates in women.

Authors:  Piotr J Slomka; Hidetaka Nishina; Aiden Abidov; Sean W Hayes; John D Friedman; Daniel S Berman; Guido Germano
Journal:  J Nucl Cardiol       Date:  2007-01       Impact factor: 5.952

10.  High-speed myocardial perfusion imaging initial clinical comparison with conventional dual detector anger camera imaging.

Authors:  Tali Sharir; Simona Ben-Haim; Konstantine Merzon; Vitali Prochorov; Dalia Dickman; Shlomo Ben-Haim; Daniel S Berman
Journal:  JACC Cardiovasc Imaging       Date:  2008-03
View more
  23 in total

1.  Nuclear cardiology as it should look in the twenty-first century.

Authors:  W Lane Duvall; Milena J Henzlova
Journal:  J Nucl Cardiol       Date:  2015-05-14       Impact factor: 5.952

2.  Advances in imaging instrumentation for nuclear cardiology.

Authors:  Jae Sung Lee; Gil Kovalski; Tali Sharir; Dong Soo Lee
Journal:  J Nucl Cardiol       Date:  2017-07-17       Impact factor: 5.952

Review 3.  Single Photon Emission Computed Tomography (SPECT) Myocardial Perfusion Imaging Guidelines: Instrumentation, Acquisition, Processing, and Interpretation.

Authors:  Sharmila Dorbala; Karthik Ananthasubramaniam; Ian S Armstrong; Panithaya Chareonthaitawee; E Gordon DePuey; Andrew J Einstein; Robert J Gropler; Thomas A Holly; John J Mahmarian; Mi-Ae Park; Donna M Polk; Raymond Russell; Piotr J Slomka; Randall C Thompson; R Glenn Wells
Journal:  J Nucl Cardiol       Date:  2018-10       Impact factor: 5.952

4.  Influence of SPECT attenuation correction on the quantification of hibernating myocardium as derived from combined myocardial perfusion SPECT and ¹⁸F-FDG PET.

Authors:  Sebastian Lehner; Christian Sussebach; Andrei Todica; Christopher Uebleis; Stefan Brunner; Peter Bartenstein; Serge D Van Kriekinge; Guido Germano; Marcus Hacker
Journal:  J Nucl Cardiol       Date:  2014-03-15       Impact factor: 5.952

5.  Quantification with normal limits: New cameras and low-dose imaging.

Authors:  Piotr J Slomka; Mathieu Rubeaux; Guido Germano
Journal:  J Nucl Cardiol       Date:  2016-06-14       Impact factor: 5.952

6.  Normal Databases for the Relative Quantification of Myocardial Perfusion.

Authors:  Mathieu Rubeaux; Yuan Xu; Guido Germano; Daniel S Berman; Piotr J Slomka
Journal:  Curr Cardiovasc Imaging Rep       Date:  2016-06-30

7.  Novel SPECT Technologies and Approaches in Cardiac Imaging.

Authors:  Piotr Slomka; Guang-Uei Hung; Guido Germano; Daniel S Berman
Journal:  Cardiovasc Innov Appl       Date:  2016-12-01

8.  Prognostic value of the cadmium-zinc-telluride camera: A comparison with a conventional (Anger) camera.

Authors:  Jorge Daniel Oldan; Linda K Shaw; Paul Hofmann; Matthew Phelan; Jeffrey Nelson; Robert Pagnanelli; Salvador Borges-Neto
Journal:  J Nucl Cardiol       Date:  2015-06-27       Impact factor: 5.952

9.  Diagnostic performance of low-dose rest/stress Tc-99m tetrofosmin myocardial perfusion SPECT using the 530c CZT camera: quantitative vs visual analysis.

Authors:  Fabio P Esteves; James R Galt; Russell D Folks; Liudmila Verdes; Ernest V Garcia
Journal:  J Nucl Cardiol       Date:  2013-11-28       Impact factor: 5.952

Review 10.  Myocardial perfusion imaging: Lessons learned and work to be done-update.

Authors:  Ami E Iskandrian; Vasken Dilsizian; Ernest V Garcia; Rob S Beanlands; Manuel Cerqueira; Prem Soman; Daniel S Berman; Alberto Cuocolo; Andrew J Einstein; Charity J Morgan; Fadi G Hage; Heinrich R Schelbert; Jeroen J Bax; Joseph C Wu; Leslee J Shaw; Mehran M Sadeghi; Nagara Tamaki; Philipp A Kaufmann; Robert Gropler; Sharmila Dorbala; William Van Decker
Journal:  J Nucl Cardiol       Date:  2017-11-06       Impact factor: 5.952

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.