Literature DB >> 28449479

Early results of the Sorin® Perceval S sutureless valve: systematic review and meta-analysis.

Karan Sian1, Sheila Li1, Daneish Selvakumar2, Ross Mejia1.   

Abstract

BACKGROUND: Minimally invasive aortic valve replacement (MAVR) has demonstrated a benefit with respect to increased patient satisfaction due to minimised pain and earlier recovery. Sutureless valves may benefit MAVR and conventional aortic valve replacement (AVR) by reducing operative times and blood transfusion requirements. The Perceval valve (Sorin, Salluggia, Italy) is a self-expanding prosthesis made from bovine pericardium mounted in a nitinol stent, designed to simplify the implantation of an aortic valve. This meta-analysis evaluates the clinical, haemodynamic, and survival outcomes of the Perceval sutureless valve.
METHODS: An electronic search of 4 databases was performed from January 2000 to December 2016. Primary outcomes included mortality and stroke. Secondary outcomes included minimally invasive access, paravalvular leak, overall long-term survival, postoperative echocardiographic findings, and functional class improvement.
RESULTS: After the application of inclusion and exclusion criteria, 14 of 66 relevant articles were selected for assessment. Of these 14 studies, a total number of 2,505 patients were included. The current evidence on the Perceval valve for aortic valve disease is limited to observational studies only. Minimally invasive surgery was performed in 976 patients, of which 336 were via the right anterior thoracotomy approach. The Perceval M and L sutureless valves were the most frequently used, 782 and 770 respectively. The incidence of major adverse events included 30-day mortality (0 to 4.9%), cerebrovascular accident (0 to 3%), permanent pacemaker insertion (0 to 17%), moderate to severe paravalvular leak (0 to 8.6%), and re-operation (0 to 4.8%). Post-operative mean aortic valve gradient ranged from 9 to 15.9 mmHg and post-operative New York Heart Association (NYHA) Class I or II ranged from 82% to 96%. The 1-year survival ranged from 86% to 100%; and 5-year survival was 71.3% to 85.5% in two studies.
CONCLUSIONS: The Perceval valve is associated with excellent post-operative results in MAVR and in conventional AVR. Larger randomised controlled studies are required to evaluate the long-term efficacy of the prosthesis.

Entities:  

Keywords:  Perceval; aortic valve replacement; meta-analysis; minimally invasive; sutureless

Year:  2017        PMID: 28449479      PMCID: PMC5394010          DOI: 10.21037/jtd.2017.03.24

Source DB:  PubMed          Journal:  J Thorac Dis        ISSN: 2072-1439            Impact factor:   2.895


  33 in total

1.  Need for permanent pacemaker as a complication of transcatheter aortic valve implantation and surgical aortic valve replacement in elderly patients with severe aortic stenosis and similar baseline electrocardiographic findings.

Authors:  Rodrigo Bagur; Josep Rodés-Cabau; Ronen Gurvitch; Éric Dumont; James L Velianou; Juan Manazzoni; Stefan Toggweiler; Anson Cheung; Jian Ye; Madhu K Natarajan; Kevin R Bainey; Robert DeLarochellière; Daniel Doyle; Philippe Pibarot; Pierre Voisine; Mélanie Côté; François Philippon; John G Webb
Journal:  JACC Cardiovasc Interv       Date:  2012-05       Impact factor: 11.195

2.  Transcatheter versus surgical aortic-valve replacement in high-risk patients.

Authors:  Craig R Smith; Martin B Leon; Michael J Mack; D Craig Miller; Jeffrey W Moses; Lars G Svensson; E Murat Tuzcu; John G Webb; Gregory P Fontana; Raj R Makkar; Mathew Williams; Todd Dewey; Samir Kapadia; Vasilis Babaliaros; Vinod H Thourani; Paul Corso; Augusto D Pichard; Joseph E Bavaria; Howard C Herrmann; Jodi J Akin; William N Anderson; Duolao Wang; Stuart J Pocock
Journal:  N Engl J Med       Date:  2011-06-05       Impact factor: 91.245

3.  Minimally invasive aortic valve replacement with Perceval S sutureless valve: early outcomes and one-year survival from two European centers.

Authors:  Antonio Miceli; Giuseppe Santarpino; Steffen Pfeiffer; Michele Murzi; Daniyar Gilmanov; Giovanni Concistré; Eugenio Quaini; Marco Solinas; Theodor Fischlein; Mattia Glauber
Journal:  J Thorac Cardiovasc Surg       Date:  2014-03-04       Impact factor: 5.209

4.  Incidence and predictors of atrioventricular conduction impairment after transcatheter aortic valve implantation.

Authors:  Laurent Roten; Peter Wenaweser; Etienne Delacrétaz; Gerrit Hellige; Stefan Stortecky; Hildegard Tanner; Thomas Pilgrim; Alexander Kadner; Balthasar Eberle; Marcel Zwahlen; Thierry Carrel; Bernhard Meier; Stephan Windecker
Journal:  Am J Cardiol       Date:  2010-11-15       Impact factor: 2.778

5.  A simple modification to lower incidence of heart block with sutureless valve implantation.

Authors:  Bobby Yanagawa; Jorge Cruz; Lyna Boisvert; Daniel Bonneau
Journal:  J Thorac Cardiovasc Surg       Date:  2016-02-24       Impact factor: 5.209

6.  Transcatheter aortic valve implantation: first results from a multi-centre real-world registry.

Authors:  Ralf Zahn; Ulrich Gerckens; Eberhard Grube; Axel Linke; Horst Sievert; Holger Eggebrecht; Rainer Hambrecht; Stefan Sack; Karl Eugen Hauptmann; Gert Richardt; Hans-Reiner Figulla; Jochen Senges
Journal:  Eur Heart J       Date:  2010-09-23       Impact factor: 29.983

7.  Sutureless aortic valve replacement: a Canadian multicentre study.

Authors:  Amine Mazine; Kevin Teoh; Ismail Bouhout; Gopal Bhatnagar; Marc Pelletier; Pierre Voisine; Philippe Demers; Michel Carrier; Denis Bouchard
Journal:  Can J Cardiol       Date:  2014-10-31       Impact factor: 5.223

8.  Effect of sutureless implantation of the Perceval S aortic valve bioprosthesis on intraoperative and early postoperative outcomes.

Authors:  Willem Flameng; Marie-Christine Herregods; Hadewich Hermans; Gerry Van der Mieren; Monique Vercalsteren; Gert Poortmans; Jan Van Hemelrijck; Bart Meuris
Journal:  J Thorac Cardiovasc Surg       Date:  2011-04-07       Impact factor: 5.209

9.  Aortic valve replacement and concomitant procedures with the Perceval valve: results of European trials.

Authors:  Malakh Shrestha; Thierry A Folliguet; Steffen Pfeiffer; Bart Meuris; Thierry Carrel; Matthias Bechtel; Willem J Flameng; Theodor Fischlein; François Laborde; Axel Haverich
Journal:  Ann Thorac Surg       Date:  2014-08-05       Impact factor: 4.330

10.  Transcatheter or Surgical Aortic-Valve Replacement in Intermediate-Risk Patients.

Authors:  Martin B Leon; Craig R Smith; Michael J Mack; Raj R Makkar; Lars G Svensson; Susheel K Kodali; Vinod H Thourani; E Murat Tuzcu; D Craig Miller; Howard C Herrmann; Darshan Doshi; David J Cohen; Augusto D Pichard; Samir Kapadia; Todd Dewey; Vasilis Babaliaros; Wilson Y Szeto; Mathew R Williams; Dean Kereiakes; Alan Zajarias; Kevin L Greason; Brian K Whisenant; Robert W Hodson; Jeffrey W Moses; Alfredo Trento; David L Brown; William F Fearon; Philippe Pibarot; Rebecca T Hahn; Wael A Jaber; William N Anderson; Maria C Alu; John G Webb
Journal:  N Engl J Med       Date:  2016-04-02       Impact factor: 91.245

View more
  2 in total

1.  Long-term outcomes of sutureless and rapid-deployment aortic valve replacement: a systematic review and meta-analysis.

Authors:  Michael L Williams; Campbell D Flynn; Andrew A Mamo; David H Tian; Utz Kappert; Manuel Wilbring; Thierry Folliguet; Antonio Fiore; Antonio Miceli; Augusto D'Onofrio; Giorgia Cibin; Gino Gerosa; Mattia Glauber; Theodor Fischlein; Francesco Pollari
Journal:  Ann Cardiothorac Surg       Date:  2020-07

2.  Mid-term follow-up after suture-less aortic heart valve implantation.

Authors:  Grzegorz Filip; Radoslaw Litwinowicz; Boguslaw Kapelak; Jacek Piatek; Magdalena Bartus; Janusz Konstanty-Kalandyk; Maciej Brzezinski; Krzysztof Bartus
Journal:  J Thorac Dis       Date:  2018-11       Impact factor: 2.895

  2 in total