OBJECTIVE: Prolonged aortic crossclamping can increase mortality and morbidity after aortic valve replacement in elderly and high-risk patients. Sutureless implantation of the prosthesis has the potential to shorten aortic crossclamp time. METHODS: The Perceval S valve (Sorin Biomedica Cardio Srl, Sallugia, Italy), a sutureless implantable aortic bioprosthesis, was used in 32 patients (median age, 78 years; median logistic euroSCORE, 9.99) requiring aortic valve replacement with or without concomitant coronary artery bypass grafting. Hemodynamic parameters and clinical outcome were obtained at discharge, at 6 months, and up to 1 year postoperatively. RESULTS: Aortic crossclamp time needed for aortic valve replacement was 18 ± 6 minutes. Hemodynamics at discharge showed good function of all Perceval S valves with low transvalvular pressure gradients (mean, 12 ± 5 mm Hg and peak, 23 ± 9 mm Hg) and low incidence of paravalvular or valvular leakage. Operative mortality was 0%. Follow-up at 1 year showed 3 non-valve-related deaths. Survivors showed good clinical outcome and stable hemodynamic function of the valve prosthesis, except for 1 patient in whom endocarditis developed. Despite a moderate decrease in platelet counts persisting up to 12 months, freedom of bleeding and thromboembolic events was 100%. CONCLUSIONS: It is possible to implant a well-functioning sutureless stent-mounted valve in the aortic position in less than 20 minutes of aortic crossclamping. This is associated with excellent early clinical and hemodynamic outcome in high-risk patients. Moderate changes in hematologic parameters persisted but were not related to clinical events.
OBJECTIVE: Prolonged aortic crossclamping can increase mortality and morbidity after aortic valve replacement in elderly and high-risk patients. Sutureless implantation of the prosthesis has the potential to shorten aortic crossclamp time. METHODS: The Perceval S valve (Sorin Biomedica Cardio Srl, Sallugia, Italy), a sutureless implantable aortic bioprosthesis, was used in 32 patients (median age, 78 years; median logistic euroSCORE, 9.99) requiring aortic valve replacement with or without concomitant coronary artery bypass grafting. Hemodynamic parameters and clinical outcome were obtained at discharge, at 6 months, and up to 1 year postoperatively. RESULTS: Aortic crossclamp time needed for aortic valve replacement was 18 ± 6 minutes. Hemodynamics at discharge showed good function of all Perceval S valves with low transvalvular pressure gradients (mean, 12 ± 5 mm Hg and peak, 23 ± 9 mm Hg) and low incidence of paravalvular or valvular leakage. Operative mortality was 0%. Follow-up at 1 year showed 3 non-valve-related deaths. Survivors showed good clinical outcome and stable hemodynamic function of the valve prosthesis, except for 1 patient in whom endocarditis developed. Despite a moderate decrease in platelet counts persisting up to 12 months, freedom of bleeding and thromboembolic events was 100%. CONCLUSIONS: It is possible to implant a well-functioning sutureless stent-mounted valve in the aortic position in less than 20 minutes of aortic crossclamping. This is associated with excellent early clinical and hemodynamic outcome in high-risk patients. Moderate changes in hematologic parameters persisted but were not related to clinical events.
Authors: Giuseppe Santarpino; Steffen Pfeiffer; Francesco Pollari; Giovanni Concistrè; Ferdinand Vogt; Theodor Fischlein Journal: Interact Cardiovasc Thorac Surg Date: 2013-10-08
Authors: Marco Di Eusanio; Kevin Phan; Denis Bouchard; Thierry P Carrel; Otto E Dapunt; Roberto Di Bartolomeo; Harald C Eichstaedt; Theodor Fischlein; Thierry Folliguet; Borut Gersak; Mattia Glauber; Axel Haverich; Martin Misfeld; Peter J Oberwalder; Giuseppe Santarpino; Malakh Lal Shrestha; Marco Solinas; Marco Vola; Francesco Alamanni; Alberto Albertini; Gopal Bhatnagar; Michel Carrier; Stephen Clark; Federic Collart; Utz Kappert; Alfred Kocher; Bart Meuris; Carmelo Mignosa; Ahmed Ouda; Marc Pelletier; Parwis Baradaran Rahmanian; David Reineke; Kevin Teoh; Giovanni Troise; Emmanuel Villa; Thorsten Wahlers; Tristan D Yan Journal: Ann Cardiothorac Surg Date: 2015-03
Authors: Kevin Phan; Yi-Chin Tsai; Nithya Niranjan; Denis Bouchard; Thierry P Carrel; Otto E Dapunt; Harald C Eichstaedt; Theodor Fischlein; Borut Gersak; Mattia Glauber; Axel Haverich; Martin Misfeld; Peter J Oberwalder; Giuseppe Santarpino; Malakh Lal Shrestha; Marco Solinas; Marco Vola; Tristan D Yan; Marco Di Eusanio Journal: Ann Cardiothorac Surg Date: 2015-03
Authors: Tomoyuki Minami; Sarah Sainte; Herbert De Praetere; Filip Rega; Willem Flameng; Peter Verbrugghe; Bart Meuris Journal: Surg Today Date: 2017-04-06 Impact factor: 2.549
Authors: Muhammet Onur Hanedan; Mehmet Ali Yuruk; Ali Ihsan Parlar; Ugur Ziyrek; Ali Kemal Arslan; Ufuk Sayar; Ilker Mataraci Journal: Tex Heart Inst J Date: 2018-02-01
Authors: Ferdinand Vogt; Steffen Pfeiffer; Angelo Maria Dell'Aquila; Theodor Fischlein; Giuseppe Santarpino Journal: Interact Cardiovasc Thorac Surg Date: 2015-11-27