Literature DB >> 21059439

Incidence and predictors of atrioventricular conduction impairment after transcatheter aortic valve implantation.

Laurent Roten1, Peter Wenaweser, Etienne Delacrétaz, Gerrit Hellige, Stefan Stortecky, Hildegard Tanner, Thomas Pilgrim, Alexander Kadner, Balthasar Eberle, Marcel Zwahlen, Thierry Carrel, Bernhard Meier, Stephan Windecker.   

Abstract

Atrioventricular (AV) conduction impairment is well described after surgical aortic valve replacement, but little is known in patients undergoing transcatheter aortic valve implantation (TAVI). We assessed AV conduction and need for a permanent pacemaker in patients undergoing TAVI with the Medtronic CoreValve Revalving System (MCRS) or the Edwards Sapien Valve (ESV). Sixty-seven patients without pre-existing permanent pacemaker were included in the study. Forty-one patients (61%) and 26 patients (39%) underwent successful TAVI with the MCRS and ESV, respectively. Complete AV block occurred in 15 patients (22%), second-degree AV block in 4 (6%), and new left bundle branch block in 15 (22%), respectively. A permanent pacemaker was implanted in 23 patients (34%). Overall PR interval and QRS width increased significantly after the procedure (p <0.001 for the 2 comparisons). Implantation of the MCRS compared to the ESV resulted in a trend toward a higher rate of new left bundle branch block and complete AV block (29% vs 12%, p = 0.09 for the 2 comparisons). During follow-up, complete AV block resolved in 64% of patients. In multivariable regression analysis pre-existing right bundle branch block was the only independent predictor of complete AV block after TAVI (relative risk 7.3, 95% confidence interval 2.4 to 22.2). In conclusion, TAVI is associated with impairment of AV conduction in a considerable portion of patients, patients with pre-existing right bundle branch block are at increased risk of complete AV block, and complete AV block resolves over time in most patients.
Copyright © 2010 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 21059439     DOI: 10.1016/j.amjcard.2010.07.012

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  28 in total

Review 1.  [Transcatheter aortic valve implantation : what do anesthetists need to know?].

Authors:  C Riediger; F Nietlispach; F Rüter; J Fassl
Journal:  Anaesthesist       Date:  2011-12       Impact factor: 1.041

Review 2.  Transcatheter aortic valve insertion (TAVI): a review.

Authors:  B Clayton; G Morgan-Hughes; C Roobottom
Journal:  Br J Radiol       Date:  2013-11-20       Impact factor: 3.039

3.  Early results of the Sorin® Perceval S sutureless valve: systematic review and meta-analysis.

Authors:  Karan Sian; Sheila Li; Daneish Selvakumar; Ross Mejia
Journal:  J Thorac Dis       Date:  2017-03       Impact factor: 2.895

4.  Conduction disorders after transcatheter aortic valve implantation: a focused review.

Authors:  Kelly M W McDonnell; Richard K Shepard
Journal:  Curr Treat Options Cardiovasc Med       Date:  2013-08

Review 5.  Clinical significance of conduction disturbances after aortic valve intervention: current evidence.

Authors:  Manuel Martinez-Selles; Peter Bramlage; Martin Thoenes; Gerhard Schymik
Journal:  Clin Res Cardiol       Date:  2014-07-04       Impact factor: 5.460

Review 6.  Transcatheter aortic valve implantation-induced left bundle branch block: causes and consequences.

Authors:  Thomas T Poels; Patrick Houthuizen; Leen A F M Van Garsse; Jos G Maessen; Peter de Jaegere; Frits W Prinzen
Journal:  J Cardiovasc Transl Res       Date:  2014-05-07       Impact factor: 4.132

7.  Transient and persistent conduction abnormalities following transcatheter aortic valve replacement with the Edwards-Sapien prosthesis: a comparison between antegrade vs. retrograde approaches.

Authors:  Solomon J Sager; Abdulla A Damluji; Joshua A Cohen; Sachil Shah; Brian P O'Neill; Carlos E Alfonso; Claudia A Martinez; Robert J Myerburg; Alan W Heldman; Mauricio G Cohen; Donald B Williams; Roger G Carrillo
Journal:  J Interv Card Electrophysiol       Date:  2016-05-28       Impact factor: 1.900

8.  Permanent-temporary pacemakers in the management of patients with conduction abnormalities after transcatheter aortic valve replacement.

Authors:  Derek Leong; Ali A Sovari; Ashkan Ehdaie; Tarun Chakravarty; Qiang Liu; Hasan Jilaihawi; Rajendra Makkar; Xunzhang Wang; Eugenio Cingolani; Michael Shehata
Journal:  J Interv Card Electrophysiol       Date:  2018-03-12       Impact factor: 1.900

9.  Incidence of arrhythmias and impact of permanent pacemaker implantation in hospitalizations with transcatheter aortic valve replacement.

Authors:  Rajkumar Doshi; Dean H Decter; Perwaiz Meraj
Journal:  Clin Cardiol       Date:  2018-05-10       Impact factor: 2.882

10.  Ongoing requirement for pacing post-transcatheter aortic valve implantation and surgical aortic valve replacement.

Authors:  Alexander D Simms; Andrew J Hogarth; Elizabeth A Hudson; Victoria L Worsnop; Daniel J Blackman; David J O'Regan; Muzahir H Tayebjee
Journal:  Interact Cardiovasc Thorac Surg       Date:  2013-04-25
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.