Abstract

For the first six weeks following total knee arthroplasty (TKA), a patient will attend an outpatient clinic typically seen twice weekly. Here, an exercise regime is performed and improvement assessed using a hand held goniometer that measures the maximum angle of knee flexion, an important metric of progress. Additionally a series of daily exercises is performed at home, recorded in a diary. This protocol has problems. Patients must attend the hospital with assistance since they are not permitted to drive for six weeks following the procedure; appointments are sometimes missed; there are occasionally not enough physiotherapy appointment available; furthermore, it is difficult to be sure that patients are compliant with their exercises at home. The economic and social costs are therefore significant both to the patient and the health service. We describe here an automatic system that performs the monitoring of knee flexion within a domestic environment rather than in a hospital setting. It comprises a master and slave sensor unit that attach using Velcro straps to the thigh and shin above and below the operation wound. The patient performs the prescribed knee exercises whilst wearing the device, during which time it measures and records the angles of knee flexion. The device utilises the Global System for Mobile Communications (GSM) infrastructure to transmit data through the Internet to a secure hospital-based server using an on-board GSM modem. The clinician is then able to view and interpret the information from any computer with internet access and the software. The system does not require the patient to possess a mobile telephone, a computer, or have internet access; the necessary communications technology is completely integrated into the device.

Entities:  

Keywords:  Flexion; Remote monitoring; Telemonitoring; Total knee arthroplasty; mHealth

Mesh:

Year:  2017        PMID: 28421308     DOI: 10.1007/s10916-017-0735-2

Source DB:  PubMed          Journal:  J Med Syst        ISSN: 0148-5598            Impact factor:   4.460


  11 in total

1.  Brake response time after total knee arthroplasty: when is it safe for patients to drive?

Authors:  Jeffery L Pierson; Donald R Earles; Karen Wood
Journal:  J Arthroplasty       Date:  2003-10       Impact factor: 4.757

2.  The frequency of visits by the physiotherapist of patients receiving home-based exercise therapy for knee osteoarthritis.

Authors:  Ayse Sen; Zeliha Gocen; Bayram Unver; Vasfi Karatosun; Izge Gunal
Journal:  Knee       Date:  2004-04       Impact factor: 2.199

3.  Planning for Internet connectivity in remote patient monitoring.

Authors:  George Pappas
Journal:  Telemed J E Health       Date:  2010-06       Impact factor: 3.536

4.  Projections of primary and revision hip and knee arthroplasty in the United States from 2005 to 2030.

Authors:  Steven Kurtz; Kevin Ong; Edmund Lau; Fionna Mowat; Michael Halpern
Journal:  J Bone Joint Surg Am       Date:  2007-04       Impact factor: 5.284

5.  Efficacy of an accelerated recovery protocol for Oxford unicompartmental knee arthroplasty--a randomised controlled trial.

Authors:  K A Reilly; D J Beard; K L Barker; C A F Dodd; A J Price; D W Murray
Journal:  Knee       Date:  2005-10       Impact factor: 2.199

6.  Patient compliance with paper and electronic diaries.

Authors:  Arthur A Stone; Saul Shiffman; Joseph E Schwartz; Joan E Broderick; Michael R Hufford
Journal:  Control Clin Trials       Date:  2003-04

7.  Usefulness of remote monitoring in cardiac implantable device follow-up.

Authors:  Carsten Stoepel; Jean Boland; Rachele Busca; Gauri Saal; Mário Oliveira
Journal:  Telemed J E Health       Date:  2009-12       Impact factor: 3.536

8.  Symptom recording in a randomised clinical trial: paper diaries vs. electronic or telephone data capture.

Authors:  Karsten Lauritsen; Alessio Degl' Innocenti; Lene Hendel; Jørgen Praest; Mogens F Lytje; Kjeld Clemmensen-Rotne; Ingela Wiklund
Journal:  Control Clin Trials       Date:  2004-12

9.  Measuring flexion in knee arthroplasty patients.

Authors:  John Z Edwards; Kenneth A Greene; Robert S Davis; Mark W Kovacik; Donald A Noe; Michael J Askew
Journal:  J Arthroplasty       Date:  2004-04       Impact factor: 4.757

10.  Home exercises are as effective as outpatient hydrotherapy for osteoarthritis of the hip.

Authors:  J Green; F McKenna; E J Redfern; M A Chamberlain
Journal:  Br J Rheumatol       Date:  1993-09
View more
  6 in total

Review 1.  A Smarter Health through the Internet of Surgical Things.

Authors:  Francesk Mulita; Georgios-Ioannis Verras; Christos-Nikolaos Anagnostopoulos; Konstantinos Kotis
Journal:  Sensors (Basel)       Date:  2022-06-17       Impact factor: 3.847

Review 2.  Technological Requirements and Challenges in Wireless Body Area Networks for Health Monitoring: A Comprehensive Survey.

Authors:  Lisha Zhong; Shuling He; Jinzhao Lin; Jia Wu; Xi Li; Yu Pang; Zhangyong Li
Journal:  Sensors (Basel)       Date:  2022-05-06       Impact factor: 3.847

Review 3.  A review of computational approaches for evaluation of rehabilitation exercises.

Authors:  Yalin Liao; Aleksandar Vakanski; Min Xian; David Paul; Russell Baker
Journal:  Comput Biol Med       Date:  2020-03-04       Impact factor: 4.589

4.  Force detection, center of pressure tracking, and energy harvesting from a piezoelectric knee implant.

Authors:  Mohsen Safaei; R Michael Meneghini; Steven R Anton
Journal:  Smart Mater Struct       Date:  2018-09-25       Impact factor: 3.585

5.  Validation of a Novel Device for the Knee Monitoring of Orthopaedic Patients.

Authors:  Mahmut Enes Kayaalp; Alison N Agres; Jan Reichmann; Maxim Bashkuev; Georg N Duda; Roland Becker
Journal:  Sensors (Basel)       Date:  2019-11-27       Impact factor: 3.576

6.  Smartphone App with an Accelerometer Enhances Patients' Physical Activity Following Elective Orthopedic Surgery: A Pilot Study.

Authors:  Hanneke C van Dijk-Huisman; Anouk T R Weemaes; Tim A E J Boymans; Antoine F Lenssen; Rob A de Bie
Journal:  Sensors (Basel)       Date:  2020-08-02       Impact factor: 3.576

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.