| Literature DB >> 28420648 |
Kimon Bekelis1,2, Symeon Missios3, Todd A MacKenzie2,4,5,6.
Abstract
BACKGROUND: It is not clear whether Magnet recognition by the American Nurses Credentialing Center (nursing excellence program) is associated with improved patient outcomes. We investigated whether hospitalization in a Magnet hospital is associated with improved outcomes for patients with ischemic stroke. METHODS ANDEntities:
Keywords: zzm321990SPARCSzzm321990; center of excellence; ischemic stroke; magnet recognition; public reporting
Mesh:
Year: 2017 PMID: 28420648 PMCID: PMC5533045 DOI: 10.1161/JAHA.117.005880
Source DB: PubMed Journal: J Am Heart Assoc ISSN: 2047-9980 Impact factor: 5.501
Patient Characteristics
| All Patients | Patients Treated in Magnet Hospitals | Patients Treated in Non‐Magnet Hospitals |
| ||||
|---|---|---|---|---|---|---|---|
| N=176 557 | N=32 092 | N=144 465 | |||||
| Mean | SD | Mean | SD | Mean | SD | ||
| Age | 71.32 | 14.88 | 72.07 | 14.76 | 71.16 | 14.90 | <0.0001 |
| N | % | N | % | N | % |
| |
| Female sex | 93 511 | 53.0 | 17 014 | 53.02 | 76 483 | 52.94 | 0.810 |
| Race | |||||||
| White | 106 983 | 60.8 | 22 898 | 71.57 | 84 083 | 58.38 | <0.0001 |
| Black | 33 802 | 19.2 | 4624 | 14.45 | 29 170 | 20.25 | <0.0001 |
| Hispanic | 15 520 | 8.8 | 1738 | 5.43 | 13 780 | 9.57 | <0.0001 |
| Asian | 4974 | 2.8 | 816 | 2.55 | 4157 | 2.89 | 0.001 |
| Other | 14 763 | 8.4 | 1916 | 5.99 | 12 846 | 8.92 | <0.0001 |
| Insurance | |||||||
| Medicare | 105 307 | 59.7 | 18 887 | 58.9 | 86 418 | 59.94 | 0.001 |
| Medicaid | 12 133 | 6.9 | 1621 | 5.05 | 10 510 | 7.29 | <0.0001 |
| Private | 50 514 | 28.7 | 9278 | 28.93 | 41 228 | 28.6 | 0.182 |
| Uninsured | 6766 | 3.8 | 2107 | 6.57 | 4657 | 3.23 | <0.0001 |
| Other | 1536 | 0.9 | 175 | 0.55 | 1361 | 0.94 | <0.0001 |
| Transient ischemic attack | 12 725 | 7.2 | 2472 | 7.7 | 10 253 | 7.1 | 0.0001 |
| Coronary artery disease | 54 593 | 30.9 | 10 546 | 32.86 | 44 047 | 30.49 | <0.0001 |
| Chronic obstructive pulmonary disease | 25 169 | 14.3 | 4546 | 14.17 | 20 623 | 14.28 | 0.610 |
| Congestive heart failure | 31 906 | 18.1 | 5893 | 18.36 | 26 013 | 18.01 | 0.133 |
| Diabetes mellitus | 59 964 | 34.0 | 9990 | 31.13 | 49 974 | 34.59 | <0.0001 |
| Coagulopathy | 5506 | 3.1 | 1213 | 3.78 | 4291 | 2.97 | <0.0001 |
| Chronic renal failure | 24 413 | 13.8 | 4746 | 14.79 | 19 667 | 13.61 | <0.0001 |
| Hypertension | 135 560 | 76.8 | 24 077 | 75.02 | 111 483 | 77.17 | <0.0001 |
| Smoking | 19 568 | 11.1 | 3469 | 10.81 | 16 096 | 11.14 | 0.086 |
| Hypercholesterolemia | 79 928 | 45.3 | 14 807 | 46.14 | 65 119 | 45.08 | 0.001 |
| Obesity | 10 811 | 6.1 | 1829 | 5.7 | 8980 | 6.22 | 0.001 |
| Alcohol | 6460 | 3.7 | 945 | 2.94 | 5515 | 3.82 | <0.0001 |
| Peripheral vascular disease | 13 112 | 7.4 | 2705 | 8.43 | 10 407 | 7.20 | <0.0001 |
| Treated with IV tPA | 10 160 | 5.75 | 1928 | 6.00 | 8232 | 5.70 | 0.031 |
| Received mechanical thrombectomy | 1308 | 0.74 | 154 | 0.48 | 1154 | 0.80 | <0.0001 |
| Received both treatments | 717 | 0.41 | 68 | 0.21 | 649 | 0.45 | <0.0001 |
IV tPA indicates intravenous tissue plasminogen activator.
Magnet Status and Unadjusted Outcomes
| Inpatient Mortality | Discharge to Rehabilitation | Length of Stay | |
|---|---|---|---|
| Patients treated in Magnet hospitals | 2525 (7.9%) | 14 390 (48.7%) | 8.8 days (SD 14.1) |
| Patients treated in non‐Magnet hospitals | 12 855 (8.9%) | 658 589 (52.1%) | 9.1 days (SD 15.9) |
Multivariable Models Examining the Association of Magnet Status With Outcomes
| Inpatient Mortality | Discharge to Rehabilitation | Length of Stay | ||||
|---|---|---|---|---|---|---|
| Adjusted Difference (95% CI) |
| Adjusted Difference (95% CI) |
| Adjusted Difference (95% CI) |
| |
| Instrumental variable analysis | −23.9% (−29.0% to −18.7%) | <0.001 | −16.5% (−20.0% to −13.0%) | <0.001 | −0.4 (−0.8 to −0.1) | <0.001 |
| Mixed effects regression | −10.5% (−12.8% to −8.1%) | <0.001 | −10.1% (−11.7% to −8.4%) | <0.001 | −0.2 (−0.3 to −0.1) | <0.001 |
| Propensity score adjusted regression | −9.7% (−11.9% to −7.4%) | <0.001 | −9.9% (−11.6% to −8.3%) | <0.001 | NA | NA |
NA indicates not applicable.
Regressions based on probit models.
Regressions based on linear models.
Differential distance to Magnet hospital was used as an instrument of treatment hospital.