Literature DB >> 28409364

Distraction and proficiency in laparoscopy: 2D versus robotic console 3D immersion.

Steven Kim1, Audriene May2, Heidi Ryan2, Adnan Mohsin2, Shawn Tsuda2.   

Abstract

INTRODUCTION: Studies have shown that using robotic-assisted laparoscopy (RL) increases performance compared to conventional laparoscopy (CL) due to its mechanical advantages but have not assessed distraction as a factor. To determine whether the immersive aspect of the 3D optics in RL contributes to improved performance, we compared the outcomes of laparoscopic skills by using just the 3D optics of the da Vinci versus the conventional 2D monitor with and without distraction.
METHODS: Thirty-two participants without any laparoscopic experience were randomized evenly into four groups: RL, robotic-assisted laparoscopy with distraction (RL + D), CL, and conventional laparoscopy with distraction (CL + D). Each participant performed three Fundamentals of Laparoscopy Surgery tasks [peg transfer (Task 1), circle cutting (Task 2), and suturing with knot (Task 3)] for three repetitions. For each task, the mean time and errors were recorded and analyzed statistically for each group.
RESULTS: Compared to other groups, CL + D took on average 1 min longer to complete Task 1 (P = 0.001), more than 1 min to complete Task 2 (P = 0.003), and more than 2 min to complete the Task 3 (P < 0.001). On Task 2, the deviations from the pattern were shorter for RL and RL + D compared to CL and CL + D (mean 0.33 and 0.37 cm vs. 0.55 and 0.58 cm, respectively; P < 0.001). On Task 3, the deviations were also shorter for RL and RL + D compared to CL and CL + D (mean 0.23 and 0.24 mm vs. 0.61 and 0.63 mm, respectively; P < 0.001).
CONCLUSION: When distraction was introduced, CL performed significantly worse. This suggests that using the conventional 2D monitor does not help with blocking out distraction. For Tasks 2 and 3, which require more precision and depth perception, the groups that used the 3D optics had shorter mean deviations than groups that used the conventional 2D monitor. This suggests that even when the robotic arms of the da Vinci are removed, there are still advantages to the immersive 3D optics, especially when distraction is present. The immersive aspect of the 3D optics may help improve performance in the OR, allowing surgeons to be more focused on the case and have greater depth acuity.

Entities:  

Keywords:  2D monitor; 3D optics; Conventional laparoscopy; Distraction; Immersion; Robot; Surgery

Mesh:

Year:  2017        PMID: 28409364     DOI: 10.1007/s00464-017-5525-x

Source DB:  PubMed          Journal:  Surg Endosc        ISSN: 0930-2794            Impact factor:   4.584


  13 in total

1.  Comparison of robotic versus laparoscopic skills: is there a difference in the learning curve?

Authors:  Paulos Yohannes; Paul Rotariu; Peter Pinto; Arthur D Smith; Benjamin R Lee
Journal:  Urology       Date:  2002-07       Impact factor: 2.649

2.  Acquiring surgical skills: a comparative study of open versus laparoscopic surgery.

Authors:  Kesavapillai Subramonian; Suren DeSylva; Peter Bishai; Peter Thompson; Gordon Muir
Journal:  Eur Urol       Date:  2004-03       Impact factor: 20.096

3.  The Impact of Operating Room Distractions on Stress, Workload, and Teamwork.

Authors:  Ana Wheelock; Amna Suliman; Rupert Wharton; E D Babu; Louise Hull; Charles Vincent; Nick Sevdalis; Sonal Arora
Journal:  Ann Surg       Date:  2015-06       Impact factor: 12.969

4.  Three-Dimensional (3D) Vision: Does It Improve Laparoscopic Skills? An Assessment of a 3D Head-Mounted Visualization System.

Authors:  Sam B Bhayani; Gerald L Andriole
Journal:  Rev Urol       Date:  2005

5.  Learning curves of robot-assisted laparoscopic surgery compared with conventional laparoscopic surgery: an experimental study evaluating skill acquisition of robot-assisted laparoscopic tasks compared with conventional laparoscopic tasks in inexperienced users.

Authors:  Jeroen Heemskerk; Wim G van Gemert; Jolanda de Vries; Janwillem Greve; Nicole D Bouvy
Journal:  Surg Laparosc Endosc Percutan Tech       Date:  2007-06       Impact factor: 1.719

6.  The influence of three-dimensional video systems on laparoscopic task performance.

Authors:  D B Jones; J D Brewer; N J Soper
Journal:  Surg Laparosc Endosc       Date:  1996-06

7.  Comparison of two-dimensional vs three-dimensional camera systems in laparoscopic surgery.

Authors:  A C Chan; S C Chung; A P Yim; J Y Lau; E K Ng; A K Li
Journal:  Surg Endosc       Date:  1997-05       Impact factor: 4.584

8.  Impact of robotics and laparoscopy on surgical skills: A comparative study.

Authors:  Khurshid A Guru; Boris W Kuvshinoff; Sasha Pavlov-Shapiro; Marlene B Bienko; Mehr N Aftab; William E Brady; James L Mohler
Journal:  J Am Coll Surg       Date:  2006-11-13       Impact factor: 6.113

9.  Robotics versus laparoscopy--an experimental study of the transfer effect in maiden users.

Authors:  Magnus Anderberg; Johan Larsson; Christina C Kockum; Einar Arnbjörnsson
Journal:  Ann Surg Innov Res       Date:  2010-04-06

10.  Surgical robotics and laparoscopic training drills.

Authors:  Richard Sarle; Ashutosh Tewari; Alok Shrivastava; James Peabody; Mani Menon
Journal:  J Endourol       Date:  2004-02       Impact factor: 2.942

View more
  3 in total

1.  A laparoscopic study investigating 3D vs 2D imaging systems using a pelvitrainer model with experts, non-experts, and students.

Authors:  Tibor Andrea Zwimpfer; Dominik Lacher; Bernhard Fellmann-Fischer; Michael Mueller
Journal:  BMC Surg       Date:  2020-11-09       Impact factor: 2.102

2.  Tele-consent using mixed reality glasses (NREAL) in pediatric inguinal herniorrhaphy: a preliminary study.

Authors:  Won-Gun Yun; Joong Kee Youn; Hyoun-Joong Kong; Hyun-Young Kim; Dayoung Ko; Inhwa Yeom; Hyun-Jin Joo
Journal:  Sci Rep       Date:  2022-02-24       Impact factor: 4.379

3.  Comparison of Intraoperative Outcomes between Single-incision Robotic Cholecystectomy and Multi-incision Robotic Cholecystectomy.

Authors:  Philip Schertz; Subhasis Misra; David Livert; Joanne Mulligan; Chand Rohatgi
Journal:  Cureus       Date:  2019-08-13
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.