Literature DB >> 23171529

Dual-source CT coronary angiography involving injection protocol with iodine load tailored to patient body weight and body mass index: estimation of optimal contrast material dose.

Xiaomei Zhu1, Yinsu Zhu, Hai Xu, Guanyu Yang, Lijun Tang, Yi Xu.   

Abstract

BACKGROUND: Body mass index (BMI) has a positive linear influence on arterial attenuation at coronary CT angiography involving injection protocol with dose linearly tailored to body weight (BW). Excessive contrast material may inadvertently be given in heavier patients when the dose is determined by BW only.
PURPOSE: To investigate the effect of injection protocol with dose of contrast material (CM) tailored to BW and BMI on coronary arterial attenuation, contrast-to-noise ratio, and image noise at dual-source CT coronary angiography (DSCT-CA).
MATERIAL AND METHODS: A total of 233 consecutive patients (mean age, 60.2 years) undergoing DSCT-CA were included. Image acquisition protocol was standardized (120 kV, 380 mAs, and retrospective electrocardiograph-triggered DSCT-CA). CM dosage calculation was randomly categorized into groups: a BW group and a BW-BMI group. CM flow rate in both groups was calculated as dosage divided by scan time plus 8 s. Correlations between BW, BMI, and attenuations of ascending aorta (AA) above coronary ostia, left main coronary artery (LM), proximal right coronary artery (RCA), left anterior descending (LAD), and left circumflex artery (LCX), contrast to noise ratio of LM (LMCNR) and RCA (RCACNR), and image noise were evaluated with simple linear regression for two groups individually.
RESULTS: In BW group, attenuations of AA and coronary arteries showed positive linear correlations to BW and BMI. In contrast, no relationships were found in BW-BMI group. LMCNR and RCACNR were inversely determined by BW and BMI in both groups. Image noise increased with BW and BMI increasing in two groups.
CONCLUSION: BMI has a positive linear influence on arterial attenuation with fixed iodine per BW. The injection protocol with CM dose tailored to BW and BMI is reasonable during DSCT-CA.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 23171529     DOI: 10.1258/ar.2012.120362

Source DB:  PubMed          Journal:  Acta Radiol        ISSN: 0284-1851            Impact factor:   1.990


  4 in total

1.  A low-dose and an ultra-low-dose contrast agent protocol for coronary CT angiography in a clinical setting: quantitative and qualitative comparison to a standard dose protocol.

Authors:  Dominik C Benz; Christoph Gräni; Beatrice Hirt Moch; Fran Mikulicic; Jan Vontobel; Tobias A Fuchs; Julia Stehli; Olivier F Clerc; Mathias Possner; Aju P Pazhenkottil; Oliver Gaemperli; Ronny R Buechel; Philipp A Kaufmann
Journal:  Br J Radiol       Date:  2017-05-25       Impact factor: 3.039

2.  High-pitch dual-source CT coronary angiography with low volumes of contrast medium.

Authors:  Alexander Lembcke; Carsten Schwenke; Patrick A Hein; Gesine Knobloch; Tahir Durmus; Bernd Hamm; Alexander Huppertz
Journal:  Eur Radiol       Date:  2013-08-15       Impact factor: 5.315

3.  Fat volume measurements as a predictor of image noise in coronary computed tomography angiography.

Authors:  Rami M Abazid; Osama A Smettei; Ahmad Almeman; Sawsan Sayed; Hanaa Alsaqqa; Salma M Abdelmageed; Fahad J Alharbi; Abdullah M Alhabib; Mouaz H Al-Mallah
Journal:  J Saudi Heart Assoc       Date:  2018-11-17

4.  Diagnostic performance of low-radiation-dose and low-contrast-dose (double low-dose) coronary CT angiography for coronary artery stenosis.

Authors:  Wei Zhang; Zhaogui Ba; Zhenqiang Wang; Huaying Lv; Jun Zhao; Yonghua Zhang; Feixue Zhang; Lei Song
Journal:  Medicine (Baltimore)       Date:  2018-08       Impact factor: 1.817

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.