Literature DB >> 28396949

Factors influencing radiation exposure during internal fixation of hip fractures.

G A Kelly1, F E Rowan2, C Hurson2.   

Abstract

The use of fluoroscopy is of great importance for operative fixation of fractures. Previous studies have shown an increased fluoroscopy time for intramedullary nails and with junior surgeons in comparison with more experienced surgeons. We examined the impact of operation length on fluoroscopy dose, cumulative fluoroscopy time between consultant and registrar surgeons and cumulative fluoroscopy time between dynamic hip screw and intramedullary nailing. We performed a retrospective cohort study of all patients admitted to our centre over the period of 1 year. Patients who underwent dynamic hip screw (DHS) or intramedullary (IM) nailing were identified from our in-hospital hip fracture database. Intraoperative fluoroscopy images were then accessed through our hospital's medical imaging software. A total of 137 patients were identified. Fluoroscopy reports were not available for 49 patients, resulting in a final total of 88 patients. Patients whose operation lasted longer than 1 h received a statistically significant higher dose of radiation (183.83 cGYM2 vs. 368.22 cGYM2; p value 0.0002). Operations performed by a consultant resulted in less cumulative fluoroscopy time in comparison with those performed by a registrar or specialist registrar although this was not statistically significant (00:00:53 vs. 00:00:45; p vaue 0.38). Cumulative fluoroscopy time was less in dynamic hip screw compared to long intramedullary nails (00:00:39 vs. 00:01:29; p value <0.001) and short intramedullary nails (00:00:39 vs. 00:01:52; p value 0.387). Studies, which had a cumulative fluoroscopy time exceeding 50 secs, delivered a higher radiation dose (434.34cGYM2 vs. 150.51cGYM2; p value <0.001). We concluded that there is no significant impact in cumulative fluoroscopy time in operations performed by either a registrar or consultant. Dynamic hip screws have a lower fluoroscopy time in comparison with long intramedullary nails.

Entities:  

Keywords:  Dynamic hip screw; Fluoroscopy; Hip fracture; Intramedullary nail; Intraoperative; Trainee; Trainer

Mesh:

Year:  2017        PMID: 28396949     DOI: 10.1007/s00590-017-1951-7

Source DB:  PubMed          Journal:  Eur J Orthop Surg Traumatol        ISSN: 1633-8065


  23 in total

1.  Occupational exposure from common fluoroscopic projections used in orthopaedic surgery.

Authors:  Nicholas Theocharopoulos; Kostas Perisinakis; John Damilakis; George Papadokostakis; Alexander Hadjipavlou; Nicholas Gourtsoyiannis
Journal:  J Bone Joint Surg Am       Date:  2003-09       Impact factor: 5.284

2.  Measurements of surgeons' exposure to ionizing radiation dose during intraoperative use of C-arm fluoroscopy.

Authors:  Kisung Lee; Kyoung Min Lee; Moon Seok Park; Boram Lee; Dae Gyu Kwon; Chin Youb Chung
Journal:  Spine (Phila Pa 1976)       Date:  2012-06-15       Impact factor: 3.468

3.  Radiation exposure with use of the mini-C-arm for routine orthopaedic imaging procedures.

Authors:  Brian L Badman; Lynn Rill; Bradley Butkovich; Manuel Arreola; Robert A Vander Griend
Journal:  J Bone Joint Surg Am       Date:  2005-01       Impact factor: 5.284

4.  Length of stay, mortality, morbidity and delay to surgery in hip fractures.

Authors:  K A Lefaivre; S A Macadam; D J Davidson; R Gandhi; H Chan; H M Broekhuyse
Journal:  J Bone Joint Surg Br       Date:  2009-07

5.  Current and projected rates of hip fracture in Canada.

Authors:  E A Papadimitropoulos; P C Coyte; R G Josse; C E Greenwood
Journal:  CMAJ       Date:  1997-11-15       Impact factor: 8.262

6.  Increased cancer risk among surgeons in an orthopaedic hospital.

Authors:  Giuseppe Mastrangelo; Ugo Fedeli; Emanuela Fadda; Angelo Giovanazzi; Luca Scoizzato; Bruno Saia
Journal:  Occup Med (Lond)       Date:  2005-09       Impact factor: 1.611

7.  Exposure of the orthopaedic surgeon to radiation.

Authors:  R Sanders; K J Koval; T DiPasquale; G Schmelling; S Stenzler; E Ross
Journal:  J Bone Joint Surg Am       Date:  1993-03       Impact factor: 5.284

8.  Optimization of a fluoroscope to reduce radiation exposure in pediatric imaging.

Authors:  P H Brown; R D Thomas; P J Silberberg; L M Johnson
Journal:  Pediatr Radiol       Date:  2000-04

9.  Cancer risks attributable to low doses of ionizing radiation: assessing what we really know.

Authors:  David J Brenner; Richard Doll; Dudley T Goodhead; Eric J Hall; Charles E Land; John B Little; Jay H Lubin; Dale L Preston; R Julian Preston; Jerome S Puskin; Elaine Ron; Rainer K Sachs; Jonathan M Samet; Richard B Setlow; Marco Zaider
Journal:  Proc Natl Acad Sci U S A       Date:  2003-11-10       Impact factor: 11.205

10.  Radiation exposure from fluoroscopy during fixation of hip fracture and fracture of ankle: Effect of surgical experience.

Authors:  Rajesh Botchu; Kassetti Ravikumar
Journal:  Indian J Orthop       Date:  2008-10       Impact factor: 1.251

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.