Literature DB >> 28324260

Stroke and Intracranial Hemorrhage in HeartMate II and HeartWare Left Ventricular Assist Devices: A Systematic Review.

Sung M Cho1, Nader Moazami2, Jennifer A Frontera3.   

Abstract

BACKGROUND: Ischemic stroke and intracranial hemorrhage (ICH) following left ventricular assist device (LVAD) placement are major causes of morbidity. The incidence and mortality associated with these events stratified by device type have not been systematically explored.
METHODS: A systematic review of PubMed was conducted from January 2007 through June 2016 for all English-language articles involving HeartMate II (HMII) and HeartWare LVAD patients. Ischemic stroke and/or ICH incidence (events per patient-year) and associated mortality rates were abstracted for each device type.
RESULTS: Of 735 articles reviewed, 48 (11,310 patients) met inclusion criteria (33 HMII, six HeartWare, eight both devices, and one unspecified). The median duration of device support was 112 days (total 13,723 patient-years). Overall, ischemic stroke or ICH occurred in 9.8% (1110 persons and 0.08 events per patient year [EPPY]). Ischemic stroke occurred in a median of 6.0% or 0.06 EPPY (range 0-16% or 0-0.21 EPPY) of HMII patients versus 7.5% or 0.09 EPPY (range 4-17.1% or 0.01-0.94 EPPY) of HeartWare patients. ICH occurred in a median of 3.0% or 0.04 EPPY (range 0-13.5% or 0-0.13 EPPY) of HMII and 8.0% or 0.08 EPPY (range 3-23% or 0.01-0.56 EPPY) of HeartWare patients. The median mortality rate for LVAD-associated ischemic stroke was 31% (HMII: 33%, [range 2.4-75%] and HeartWare: 11.5% [range 3.9-40%]), and the median mortality rate following ICH was 71% (HMII: 75%, [range 3.9-100%] and HeartWare: 44%, [range 3.1-88%]).
CONCLUSIONS: Ischemic stroke and ICH are common after LVAD placement, but heterogeneous event rates are reported in the literature. Given the high associated mortality, further prospective study is warranted.

Entities:  

Keywords:  HeartMate II (HMII); HeartWare (HVAD); ICH; Ischemic stroke; Left ventricular assisted device (LVAD)

Mesh:

Year:  2017        PMID: 28324260     DOI: 10.1007/s12028-017-0386-7

Source DB:  PubMed          Journal:  Neurocrit Care        ISSN: 1541-6933            Impact factor:   3.210


  57 in total

1.  Blood pressure and adverse events during continuous flow left ventricular assist device support.

Authors:  Omar Saeed; Rita Jermyn; Faraj Kargoli; Shivank Madan; Santhosh Mannem; Sampath Gunda; Cecilia Nucci; Sarah Farooqui; Syed Hassan; Allison Mclarty; Michelle Bloom; Ronald Zolty; Julia Shin; David D'Alessandro; Daniel J Goldstein; Snehal R Patel
Journal:  Circ Heart Fail       Date:  2015-04-13       Impact factor: 8.790

2.  Use of an intrapericardial, continuous-flow, centrifugal pump in patients awaiting heart transplantation.

Authors:  Keith D Aaronson; Mark S Slaughter; Leslie W Miller; Edwin C McGee; William G Cotts; Michael A Acker; Mariell L Jessup; Igor D Gregoric; Pranav Loyalka; O H Frazier; Valluvan Jeevanandam; Allen S Anderson; Robert L Kormos; Jeffrey J Teuteberg; Wayne C Levy; David C Naftel; Richard M Bittman; Francis D Pagani; David R Hathaway; Steven W Boyce
Journal:  Circulation       Date:  2012-05-22       Impact factor: 29.690

3.  2013 ACCF/AHA guideline for the management of heart failure: executive summary: a report of the American College of Cardiology Foundation/American Heart Association Task Force on practice guidelines.

Authors:  Clyde W Yancy; Mariell Jessup; Biykem Bozkurt; Javed Butler; Donald E Casey; Mark H Drazner; Gregg C Fonarow; Stephen A Geraci; Tamara Horwich; James L Januzzi; Maryl R Johnson; Edward K Kasper; Wayne C Levy; Frederick A Masoudi; Patrick E McBride; John J V McMurray; Judith E Mitchell; Pamela N Peterson; Barbara Riegel; Flora Sam; Lynne W Stevenson; W H Wilson Tang; Emily J Tsai; Bruce L Wilkoff
Journal:  Circulation       Date:  2013-06-05       Impact factor: 29.690

4.  Pre-operative and post-operative risk factors associated with neurologic complications in patients with advanced heart failure supported by a left ventricular assist device.

Authors:  Tomoko S Kato; P Christian Schulze; Jonathan Yang; Ernest Chan; Khurram Shahzad; Hiroo Takayama; Nir Uriel; Ulrich Jorde; Maryjane Farr; Yoshifumi Naka; Donna Mancini
Journal:  J Heart Lung Transplant       Date:  2011-10-08       Impact factor: 10.247

5.  Hemolysis: a harbinger of adverse outcome after left ventricular assist device implant.

Authors:  Jennifer A Cowger; Matthew A Romano; Palak Shah; Neha Shah; Vivek Mehta; Jonathan W Haft; Keith D Aaronson; Francis D Pagani
Journal:  J Heart Lung Transplant       Date:  2013-11-28       Impact factor: 10.247

6.  Lessons learned from 150 continuous-flow left ventricular assist devices: a single institutional 7 year experience.

Authors:  Athanasios Tsiouris; Gaetano Paone; Hassan W Nemeh; Robert J Brewer; Jamil Borgi; Arielle Hodari; Jeffrey A Morgan
Journal:  ASAIO J       Date:  2015 May-Jun       Impact factor: 2.872

7.  Management of intracranial hemorrhage in patients with left ventricular assist devices.

Authors:  Thomas J Wilson; William R Stetler; Wajd N Al-Holou; Stephen E Sullivan; Jeffrey J Fletcher
Journal:  J Neurosurg       Date:  2013-03-01       Impact factor: 5.115

8.  Factors Related to Pump Thrombosis With the Heartmate II Left Ventricular Assist Device.

Authors:  Charles T Klodell; H Todd Massey; Robert M Adamson; David A Dean; Douglas A Horstmanshof; John M Ransom; Christopher T Salerno; Jennifer A Cowger; Juan M Aranda; Leway Chen; James W Long; Walter Dembitsky
Journal:  J Card Surg       Date:  2015-08-18       Impact factor: 1.620

9.  Is anti-platelet therapy needed in continuous flow left ventricular assist device patients? A single-centre experience.

Authors:  Pierre-Yves Litzler; Hassiba Smail; Virginie Barbay; Catherine Nafeh-Bizet; François Bouchart; Jean-Marc Baste; Caroline Abriou; Jean-Paul Bessou
Journal:  Eur J Cardiothorac Surg       Date:  2013-05-12       Impact factor: 4.191

10.  Reduced anticoagulation after mechanical aortic valve replacement: interim results from the prospective randomized on-X valve anticoagulation clinical trial randomized Food and Drug Administration investigational device exemption trial.

Authors:  John Puskas; Marc Gerdisch; Dennis Nichols; Reed Quinn; Charles Anderson; Birger Rhenman; Lilibeth Fermin; Michael McGrath; Bobby Kong; Chad Hughes; Gulshan Sethi; Michael Wait; Tomas Martin; Allen Graeve
Journal:  J Thorac Cardiovasc Surg       Date:  2014-01-12       Impact factor: 5.209

View more
  9 in total

Review 1.  Neurocritical Care of Mechanical Circulatory Support Devices.

Authors:  Aaron Shoskes; Glenn Whitman; Sung-Min Cho
Journal:  Curr Neurol Neurosci Rep       Date:  2021-03-10       Impact factor: 5.081

Review 2.  Neurological Complications of Cardiological Interventions.

Authors:  Amir Shaban; Enrique C Leira
Journal:  Curr Neurol Neurosci Rep       Date:  2019-02-09       Impact factor: 5.081

3.  Assessing Cerebrovascular Hemodynamics Using Transcranial Doppler in Patients with Mechanical Circulatory Support Devices.

Authors:  Kara R Melmed; Konrad H Schlick; Brenda Rinsky; Oana M Dumitrascu; Oksana Volod; Mani Nezhad; Matthew M Padrick; Carmelita Runyan; Francisco A Arabia; Jaime D Moriguchi; Patrick D Lyden; Shlee S Song
Journal:  J Neuroimaging       Date:  2020-02-10       Impact factor: 2.486

4.  Bleeding in critical care associated with left ventricular assist devices: pathophysiology, symptoms, and management.

Authors:  F W G Leebeek; R Muslem
Journal:  Hematology Am Soc Hematol Educ Program       Date:  2019-12-06

5.  Factors defining occurrence of ischemic and hemorrhagic strokes during continuous flow left ventricular assist device support.

Authors:  Athanasios Tsiouris; Ioannis Heliopoulos; Dimitrios Mikroulis; Panayiotis D Mitsias
Journal:  Gen Thorac Cardiovasc Surg       Date:  2019-08-21

6.  Cerebral Microvascular Injury in Patients with Left Ventricular Assist Device: a Neuropathological Study.

Authors:  Tracey H Fan; Sung-Min Cho; Richard A Prayson; Catherine E Hassett; Randall C Starling; Ken Uchino
Journal:  Transl Stroke Res       Date:  2021-09-08       Impact factor: 6.800

7.  The Use of Factor Eight Inhibitor Bypass Activity (FEIBA) for the Treatment of Perioperative Hemorrhage in Left Ventricular Assist Device Implantation.

Authors:  Christian O'Donnell; Alexander J Rodriguez; Jai Madhok; Husham Sharifi; Hanjay Wang; Connor G O'Brien; Jack Boyd; William Hiesinger; Joe Hsu; Charles C Hill
Journal:  J Cardiothorac Vasc Anesth       Date:  2021-04-25       Impact factor: 2.628

8.  Treatment of chronic subdural hematoma in a patient with a left ventricular assist device: Case report and review of the literature.

Authors:  Gnel Pivazyan; Mitchell B Rock; Ehsan Dowlati; Jeffrey C Mai; Robert B Mason
Journal:  Brain Circ       Date:  2022-03-21

Review 9.  Innovative Modeling Techniques and 3D Printing in Patients with Left Ventricular Assist Devices: A Bridge from Bench to Clinical Practice.

Authors:  Rishi Thaker; Raquel Araujo-Gutierrez; Hernan G Marcos-Abdala; Tanushree Agrawal; Nadia Fida; Mahwash Kassi
Journal:  J Clin Med       Date:  2019-05-09       Impact factor: 4.241

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.