Sandwich-type biosensor platforms have drawn lots of attentions due to its superior features, compared to other platforms, in terms of its stable and reproducible responses and easy enhancement in the detection sensitivity. The sandwich-type assays can be developed by utilizing a pair of receptors, which bind to the different sites of the same target. In this mini-review paper, the sandwich-type biosensors using either pairs of aptamers or aptamer-antibody pairs are reviewed in terms of its targets and platforms, the schematic designs, and their analytical performance.Entities:
Keywords: A pair of aptamer; Aptamer-antibody complex; Aptasensor; Sandwich-type aptasensor; Sandwich-type biosensors
Year: 2017 PMID: 28293287 PMCID: PMC5346835 DOI: 10.1186/s13036-017-0054-7
Source DB: PubMed Journal: J Biol Eng ISSN: 1754-1611 Impact factor: 4.355
Fig. 1An illustration showing the parameters and factors to design biosensors strategically
Fig. 2The scheme of aptamer-antibody-based sandwich-type biosensors and aptamer pair-based sandwich-type biosensors; Antibody-aptamer-based sandwich-type biosensor (a), aptamer-antibody-based sandwich-type biosensor (b), aptamer pair-based sandwich-type biosensor (c), aptamer-based sandwich-type biosensor using hands in hands nanostructure (d), FRET-based label free sandwich type biosensors (e)
A brief comparison between the sandwich-type aptasensors and immunosensors in terms of sensing modalities, sensing platforms, and sample matrices
| Target | Bioreceptors | Sensing modalities | Sensing platform | Sample matrices | LOD | Reference |
|---|---|---|---|---|---|---|
| Thrombin | Ab + Apt | Electrochemical sandwich | On the electrode | Tris-HCl buffer | 0.5 nM | [ |
| Ab + Apt | LSPR sandwich | Solution phase | Binding buffer/male human serum | 1.6 pM/50 pM | [ | |
| Apt pair | Colorimetric sandwich | 96 well plate | Binding buffer | 0.4 μM | [ | |
| Ab | Impedance | On the electrode | PBS | 100 nM | [ | |
| Apt pair | Impedance | On the electrode | Binding buffer | 100 nM | [ | |
| Apt pair | FRET label free | Solution phase | Tris-HCl buffer/Serum | 0.76 nM/130 nM | [ | |
| PDGF-BB | Ab + Apt | Electrochemical sandwich | On the electrode | Tris-HCl buffer/Human serum | 18 pg/ml | [ |
| Apt pair | Electrochemical sandwich | On the electrode | Purified sample/Blood serum | 10 fM/1 pM | [ | |
| Apt pair | Electrochemical multiple sandwich | On the electrode | Tris-HCl buffer | Less than 100fM | [ | |
| Ab | Electrochemical sandwich | On the electrode | Human serum | 0.01 ng/ml | [ | |
| CRP | Ab + Apt | Optical sandwich assay | On AR chip epoxy | Human serum | 10 μg/l | [ |
| Ab pair | Electrochemical snadwich | Electrode array | Human serum | 15 fg/ml | [ | |
| Ramos cell | Apt pair | LFA chip | Nitrocellulose membrane strip | Human blood | 800 cells | [ |
| MCF-7 | Apt pair | Electrochemical sandwich | On the electrode | PBS | 100 cells | [ |
| Ab pair | Electrochemiluminescence | on the electrode | Human serum | 4.5 fg/ml | [ | |
|
| Apt pair | Electrochemical sandwich | Solution phase | Tris-HCl buffer/real tap water and river sample | 1.0 CFU/ml/134.3 CFU/ml | [ |
| Ab | Electrochemical sandwich | On the electrode | Phospate buffer | 1000 cells/ml | [ | |
| VEGF | Apt pair | SPR sandwich | on the Au chip | Tris-HCl buffer | 100 pg/ml | [ |
| Ab pari | Electrochemical sandwich | On the electrode | Human serum | 21 cells/ml | [ | |
| Vaspin | Apt pair | SPR sandwich | on the Au chip | Binding buffer/Human serum | 3.5 ng/ml/4.7 ng/ml | [ |
| Ab + Apt | SPR based ELAAS | on the Au chip | Human serum | 39 ng/ml | [ | |
| PRRSV type II | Ab + Apt | ELAAS | 96 well plate | Binding buffer/Swine serum | 4.8 TCID50/ml | [ |
| PRRSV | Ab | Electrochemical sandwich | On the electrode | Negative serum | 380 pg/ml | [ |
| BVDV | Apt pair | SPR sandwich | on the Au chip | Binding buffer | 500 TCID50/mL | [ |
| Ab | Light scattrering | Micro fluidic cahnnel | Tissue culture media and fetal calf serum | 10 TCID50/mL | [ | |
| H5N1 | Apt pair | SPR sandwich | on the Au chip | Binding buffer | 200 EID50/ml | [ |
| Ab | Electrochemical sandwich | Micro fluidic cahnnel | Buffer | 1 pg/ml | [ |