Literature DB >> 9115687

An amperometric enzyme-channeling immunosensor.

J Rishpon1, D Ivnitski.   

Abstract

This paper presents a new disposable amperometric, enzyme-channeling immunosensor for a quantitative, rapid, separation-free enzyme immunoassay (EIA) that can be used in clinical diagnostics, as well as in biomedical, biochemical, and environmental research. The sensor consists of a disposable, polymer-modified, carbon electrode on which enzyme 1 is coimmobilized with a specific antibody that binds the corresponding antigen in a test solution. The solution also contains a conjugate of enzyme 2. An immunological reaction brings the two enzymes into close proximity at the electrode surface, and the signal is amplified through enzyme channeling. The localization of both enzymes on the electrode surface limits the enzymatic reactions to the polymer/membrane/electrode interface. The sensor overcomes the problem of discriminating between the signal that is produced by the immuno-bound enzyme label on the electrode surface and the background level of signal that emerges from the bulk solution. Combining enzyme-channeling reactions, optimizing hydrodynamic conditions, and electrochemically regenerating mediators within the membrane layer of the antibody electrode significantly increased the signal-to-noise ratio of the sensor. The amperometric enzyme-channeling immunosensor enabled the performance of separation-free EIAs without washing steps, resulting in a relatively short assay time of 5-30 min for the complete immunoassay, compared with at least 1-3 h for ELISA methods. Model systems using peroxidase-antibody, biotin-avidin, viral antigens (CD4-gp120), and bacteria (Staphylococcus aureus) were investigated. S. aureus cells were detected in pure culture at concentrations as low as 1000 cells/ml.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9115687     DOI: 10.1016/s0956-5663(97)85337-7

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  7 in total

1.  A portable array biosensor for detecting multiple analytes in complex samples.

Authors:  C R Taitt; J P Golden; Y S Shubin; L C Shriver-Lake; K E Sapsford; A Rasooly; F S Ligler
Journal:  Microb Ecol       Date:  2004-02-09       Impact factor: 4.552

2.  The use of electronic sensor in hormone analysis.

Authors:  N E Muda; M A Abu Bakar; B Y Majlis
Journal:  Malays J Med Sci       Date:  1999-07

Review 3.  Transducer Technologies for Biosensors and Their Wearable Applications.

Authors:  Emre Ozan Polat; M Mustafa Cetin; Ahmet Fatih Tabak; Ebru Bilget Güven; Bengü Özuğur Uysal; Taner Arsan; Anas Kabbani; Houmeme Hamed; Sümeyye Berfin Gül
Journal:  Biosensors (Basel)       Date:  2022-06-02

Review 4.  Aptamer-based sandwich-type biosensors.

Authors:  Ho Bin Seo; Man Bock Gu
Journal:  J Biol Eng       Date:  2017-03-13       Impact factor: 4.355

Review 5.  Microneedle-based devices for point-of-care infectious disease diagnostics.

Authors:  Rachael V Dixon; Eldhose Skaria; Wing Man Lau; Philip Manning; Mark A Birch-Machin; S Moein Moghimi; Keng Wooi Ng
Journal:  Acta Pharm Sin B       Date:  2021-02-16       Impact factor: 11.413

Review 6.  Advances in reproductive biotechnologies.

Authors:  K K Choudhary; K M Kavya; A Jerome; R K Sharma
Journal:  Vet World       Date:  2016-04-18

Review 7.  Surface Display Technology for Biosensor Applications: A Review.

Authors:  Min Park
Journal:  Sensors (Basel)       Date:  2020-05-13       Impact factor: 3.576

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.