Literature DB >> 28274033

An In-vitro Comparative Stereomicroscopic Analysis and Evaluation of Marginal Accuracy in Porcelain Fused to Metal Copings Fabricated in Two Different Finish Lines Using Variant Die Materials.

Priya L Vaswani1, Pronob K Sanyal2, Siddharth Y Gosavi3, Abhijeet R Kore4.   

Abstract

INTRODUCTION: Limited published information is available about the influence of preparatory designs and die materials on marginal accuracy of porcelain fused to metal copings using recently developed die materials. AIM: To detect the influence of margin geometries and dimensional accuracy of contemporary die materials on vertical marginal gaps in Porcelain fused to metal coping using a Stereomicroscope (three dimensional analysis). MATERIALS AND
METHOD: Two chrome cobalt alloy models of mandibular first molars prepared to have shoulder and deep chamfer finish lines were CAD-CAM milled. Elastomeric impressions of these models were made in a custom tray, poured in Type IV Gypsum(n=10) and Resin modified Gypsum(n=10) and also packed with Epoxy resin (n=10) as a die material to form a total of 60 samples, 30 in each group (shoulder and deep chamfer). Wax patterns were fabricated, invested and castings in ceramic alloy were obtained in traditional manner. These copings were later analyzed on CAD/CAM models using stereomicroscope.
RESULTS: Both the designs did not exhibit significant difference (p<0.05). Whereas, the three die materials exhibited significant difference (p<0.05) by Two way ANOVA test and Tukey's multiple Post Hoc test. Results from this study showed that vertical marginal gaps for copings fabricated on resin modified gypsum as a die material were within the clinically acceptable range.
CONCLUSION: Margin geometries both shoulder and deep chamfer have equal influence on vertical marginal gaps in metal ceramic restorations. Copings fabricated on Epoxy resin dies exhibited highest value of vertical marginal discrepancy, where as least value was determined for copings constructed on dies fabricated from resin modified gypsum.

Entities:  

Keywords:  Deep chamfer; Epoxy resin; Resin modified gypsum; Shoulder; Vertical marginal discrepancy

Year:  2017        PMID: 28274033      PMCID: PMC5324478          DOI: 10.7860/JCDR/2017/21370.9131

Source DB:  PubMed          Journal:  J Clin Diagn Res        ISSN: 0973-709X


  23 in total

Review 1.  Gingival margins for crowns: a review and discussion. Part II: Discrepancies and configurations.

Authors:  A J Hunter; A R Hunter
Journal:  J Prosthet Dent       Date:  1990-12       Impact factor: 3.426

2.  Periodontal considerations of restorative procedures.

Authors:  F Palomo; J Peden
Journal:  J Prosthet Dent       Date:  1976-10       Impact factor: 3.426

3.  Influence of finish line design on marginal adaptation of electroformed metal-ceramic crowns.

Authors:  Hisaka Shiratsuchi; Futoshi Komine; Yoshiyuki Kakehashi; Hideo Matsumura
Journal:  J Prosthet Dent       Date:  2006-03       Impact factor: 3.426

4.  Comparison of transverse strength and dimensional variations between die stone, die epoxy resin, and die polyurethane resin.

Authors:  G Derrien; G Sturtz
Journal:  J Prosthet Dent       Date:  1995-12       Impact factor: 3.426

5.  Effect of three variables on the accuracy and variability of electroplated copper dies.

Authors:  E M Cassimaty; T R Walton
Journal:  Int J Prosthodont       Date:  1996 Nov-Dec       Impact factor: 1.681

6.  An in vivo evaluation of fit of zirconium-oxide based ceramic single crowns, generated with two CAD/CAM systems, in comparison to metal ceramic single crowns.

Authors:  Leonello Biscaro; Roberto Bonfiglioli; Massimo Soattin; Paolo Vigolo
Journal:  J Prosthodont       Date:  2012-09-04       Impact factor: 2.752

7.  Unserviceable crowns and fixed partial dentures: life-span and causes for loss of serviceability.

Authors:  N L Schwartz; L D Whitsett; T G Berry; J L Stewart
Journal:  J Am Dent Assoc       Date:  1970-12       Impact factor: 3.634

8.  Margins.

Authors:  I Gulker
Journal:  N Y State Dent J       Date:  1985-04

9.  The effects of bevel angulation on marginal integrity.

Authors:  H G Kashani; S C Khera; I A Gulker
Journal:  J Am Dent Assoc       Date:  1981-12       Impact factor: 3.634

10.  Accuracy of stone casts obtained by different impression materials.

Authors:  Adriana Cláudia Lapria Faria; Renata Cristina Silveira Rodrigues; Ana Paula Macedo; Maria da Gloria Chiarello de Mattos; Ricardo Faria Ribeiro
Journal:  Braz Oral Res       Date:  2008 Oct-Dec
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.