Literature DB >> 28260808

Exploring the limiting timing resolution for large volume CZT detectors with waveform analysis.

L J Meng1, Z He1.   

Abstract

This paper presents a study for exploring the limiting timing resolution that can be achieved with a large volume 3-D position sensitive CZT detector. The interaction timing information was obtained by fitting the measured cathode waveforms to pre-defined waveform models. We compared the results from using several different waveform models. Timing resolutions, of ~9.5 ns for 511 keV full-energy events and ~11.6 ns for all detected events with energy deposition above 250 keV, were achieved with a detailed modeling of the cathode waveform as a function of interaction location and energy deposition. This detailed modeling also allowed us to derive a theoretical lower bound for the error on estimated interaction timing. Both experimental results and theoretical predications matched well, which indicated that the best timing resolution achievable in the 1 cm3 CZT detector tested is ~10 ns. It is also showed that the correlation between sampled amplitudes in cathode waveforms is an important limiting factor for the achievable timing resolution.

Keywords:  Large volume 3-D position sensitive czt; Timing resolution; Waveform analysis

Year:  2005        PMID: 28260808      PMCID: PMC5333786          DOI: 10.1016/j.nima.2005.04.076

Source DB:  PubMed          Journal:  IEEE Trans Nucl Sci        ISSN: 0018-9499            Impact factor:   1.679


  4 in total

1.  Effect of CZT system characteristics on Compton scatter event recovery.

Authors:  Sheng Yang; Mohan Li; Michael Reed; James Hugg; Henry Chen; Shiva Abbaszadeh
Journal:  IEEE Trans Radiat Plasma Med Sci       Date:  2019-05-06

2.  Simulation study of the second-generation MR-compatible SPECT system based on the inverted compound-eye gamma camera design.

Authors:  Xiaochun Lai; Ling-Jian Meng
Journal:  Phys Med Biol       Date:  2018-02-12       Impact factor: 3.609

3.  Hybrid Pixel-Waveform (HPWF) Enabled CdTe Detectors for Small Animal Gamma-Ray Imaging Applications.

Authors:  A Groll; K Kim; H Bhatia; J C Zhang; J H Wang; Z M Shen; L Cai; J Dutta; Q Li; L J Meng
Journal:  IEEE Trans Radiat Plasma Med Sci       Date:  2016-11-01

4.  New-generation small animal positron emission tomography system for molecular imaging.

Authors:  Shiva Abbaszadeh; Craig S Levin
Journal:  J Med Imaging (Bellingham)       Date:  2017-01-12
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.