Literature DB >> 28185910

Ultrasoft microwire neural electrodes improve chronic tissue integration.

Zhanhong Jeff Du1, Christi L Kolarcik2, Takashi D Y Kozai3, Silvia D Luebben4, Shawn A Sapp5, Xin Sally Zheng6, James A Nabity7, X Tracy Cui8.   

Abstract

Chronically implanted neural multi-electrode arrays (MEA) are an essential technology for recording electrical signals from neurons and/or modulating neural activity through stimulation. However, current MEAs, regardless of the type, elicit an inflammatory response that ultimately leads to device failure. Traditionally, rigid materials like tungsten and silicon have been employed to interface with the relatively soft neural tissue. The large stiffness mismatch is thought to exacerbate the inflammatory response. In order to minimize the disparity between the device and the brain, we fabricated novel ultrasoft electrodes consisting of elastomers and conducting polymers with mechanical properties much more similar to those of brain tissue than previous neural implants. In this study, these ultrasoft microelectrodes were inserted and released using a stainless steel shuttle with polyethyleneglycol (PEG) glue. The implanted microwires showed functionality in acute neural stimulation. When implanted for 1 or 8weeks, the novel soft implants demonstrated significantly reduced inflammatory tissue response at week 8 compared to tungsten wires of similar dimension and surface chemistry. Furthermore, a higher degree of cell body distortion was found next to the tungsten implants compared to the polymer implants. Our results support the use of these novel ultrasoft electrodes for long term neural implants. STATEMENT OF SIGNIFICANCE: One critical challenge to the translation of neural recording/stimulation electrode technology to clinically viable devices for brain computer interface (BCI) or deep brain stimulation (DBS) applications is the chronic degradation of device performance due to the inflammatory tissue reaction. While many hypothesize that soft and flexible devices elicit reduced inflammatory tissue responses, there has yet to be a rigorous comparison between soft and stiff implants. We have developed an ultra-soft microelectrode with Young's modulus lower than 1MPa, closely mimicking the brain tissue modulus. Here, we present a rigorous histological comparison of this novel ultrasoft electrode and conventional stiff electrode with the same size, shape and surface chemistry, implanted in rat brains for 1-week and 8-weeks. Significant improvement was observed for ultrasoft electrodes, including inflammatory tissue reaction, electrode-tissue integration as well as mechanical disturbance to nearby neurons. A full spectrum of new techniques were developed in this study, from insertion shuttle to in situ sectioning of the microelectrode to automated cell shape analysis, all of which should contribute new methods to the field. Finally, we showed the electrical functionality of the ultrasoft electrode, demonstrating the potential of flexible neural implant devices for future research and clinical use.
Copyright © 2017. Published by Elsevier Ltd.

Entities:  

Keywords:  Composite bio-electrodes; Conducting elastomer; Deep brain stimulation; Neural electrode

Mesh:

Substances:

Year:  2017        PMID: 28185910      PMCID: PMC5512864          DOI: 10.1016/j.actbio.2017.02.010

Source DB:  PubMed          Journal:  Acta Biomater        ISSN: 1742-7061            Impact factor:   8.947


  98 in total

1.  Reduction of neurovascular damage resulting from microelectrode insertion into the cerebral cortex using in vivo two-photon mapping.

Authors:  T D Y Kozai; T C Marzullo; F Hooi; N B Langhals; A K Majewska; E B Brown; D R Kipke
Journal:  J Neural Eng       Date:  2010-07-19       Impact factor: 5.379

2.  The brain tissue response to implanted silicon microelectrode arrays is increased when the device is tethered to the skull.

Authors:  Roy Biran; Dave C Martin; Patrick A Tresco
Journal:  J Biomed Mater Res A       Date:  2007-07       Impact factor: 4.396

3.  Effects of insertion conditions on tissue strain and vascular damage during neuroprosthetic device insertion.

Authors:  C S Bjornsson; S J Oh; Y A Al-Kofahi; Y J Lim; K L Smith; J N Turner; S De; B Roysam; W Shain; S J Kim
Journal:  J Neural Eng       Date:  2006-06-21       Impact factor: 5.379

4.  Flexible polyimide-based intracortical electrode arrays with bioactive capability.

Authors:  P J Rousche; D S Pellinen; D P Pivin; J C Williams; R J Vetter; D R Kipke
Journal:  IEEE Trans Biomed Eng       Date:  2001-03       Impact factor: 4.538

5.  Matrices with compliance comparable to that of brain tissue select neuronal over glial growth in mixed cortical cultures.

Authors:  Penelope C Georges; William J Miller; David F Meaney; Evelyn S Sawyer; Paul A Janmey
Journal:  Biophys J       Date:  2006-02-03       Impact factor: 4.033

6.  In vivo impedance spectroscopy of deep brain stimulation electrodes.

Authors:  Scott F Lempka; Svjetlana Miocinovic; Matthew D Johnson; Jerrold L Vitek; Cameron C McIntyre
Journal:  J Neural Eng       Date:  2009-06-03       Impact factor: 5.379

7.  Elastomeric and soft conducting microwires for implantable neural interfaces.

Authors:  Christi L Kolarcik; Silvia D Luebben; Shawn A Sapp; Jenna Hanner; Noah Snyder; Takashi D Y Kozai; Emily Chang; James A Nabity; Shawn T Nabity; Carl F Lagenaur; X Tracy Cui
Journal:  Soft Matter       Date:  2015-05-20       Impact factor: 3.679

8.  Cerebral astrocyte response to micromachined silicon implants.

Authors:  J N Turner; W Shain; D H Szarowski; M Andersen; S Martins; M Isaacson; H Craighead
Journal:  Exp Neurol       Date:  1999-03       Impact factor: 5.330

9.  Dissolvable films of silk fibroin for ultrathin conformal bio-integrated electronics.

Authors:  Dae-Hyeong Kim; Jonathan Viventi; Jason J Amsden; Jianliang Xiao; Leif Vigeland; Yun-Soung Kim; Justin A Blanco; Bruce Panilaitis; Eric S Frechette; Diego Contreras; David L Kaplan; Fiorenzo G Omenetto; Yonggang Huang; Keh-Chih Hwang; Mitchell R Zakin; Brian Litt; John A Rogers
Journal:  Nat Mater       Date:  2010-04-18       Impact factor: 43.841

10.  Activation of extracellular signal-regulated kinase by stretch-induced injury in astrocytes involves extracellular ATP and P2 purinergic receptors.

Authors:  Joseph T Neary; Yuan Kang; Karen A Willoughby; Earl F Ellis
Journal:  J Neurosci       Date:  2003-03-15       Impact factor: 6.167

View more
  44 in total

1.  Toward guiding principles for the design of biologically-integrated electrodes for the central nervous system.

Authors:  Cort H Thompson; Ti'Air E Riggins; Paras R Patel; Cynthia A Chestek; Wen Li; Erin Purcell
Journal:  J Neural Eng       Date:  2020-03-12       Impact factor: 5.379

2.  Flexible, multifunctional neural probe with liquid metal enabled, ultra-large tunable stiffness for deep-brain chemical sensing and agent delivery.

Authors:  Ximiao Wen; Bo Wang; Shan Huang; Tingyi Leo Liu; Meng-Shiue Lee; Pei-Shan Chung; Yu Ting Chow; I-Wen Huang; Harold G Monbouquette; Nigel T Maidment; Pei-Yu Chiou
Journal:  Biosens Bioelectron       Date:  2019-02-07       Impact factor: 10.618

3.  A Materials Roadmap to Functional Neural Interface Design.

Authors:  Steven M Wellman; James R Eles; Kip A Ludwig; John P Seymour; Nicholas J Michelson; William E McFadden; Alberto L Vazquez; Takashi D Y Kozai
Journal:  Adv Funct Mater       Date:  2017-07-19       Impact factor: 18.808

Review 4.  A Critical Review of Microelectrode Arrays and Strategies for Improving Neural Interfaces.

Authors:  Morgan Ferguson; Dhavan Sharma; David Ross; Feng Zhao
Journal:  Adv Healthc Mater       Date:  2019-08-28       Impact factor: 9.933

5.  Recent Advances in Neural Electrode-Tissue Interfaces.

Authors:  Kevin Woeppel; Qianru Yang; Xinyan Tracy Cui
Journal:  Curr Opin Biomed Eng       Date:  2017-09-23

6.  Complications of epidural spinal stimulation: lessons from the past and alternatives for the future.

Authors:  Giuliano Taccola; Sean Barber; Phillip J Horner; Humberto A Cerrel Bazo; Dimitry Sayenko
Journal:  Spinal Cord       Date:  2020-06-23       Impact factor: 2.772

7.  Acute in vivo testing of a conformal polymer microelectrode array for multi-region hippocampal recordings.

Authors:  Huijing Xu; Ahuva Weltman Hirschberg; Kee Scholten; Theodore William Berger; Dong Song; Ellis Meng
Journal:  J Neural Eng       Date:  2018-02       Impact factor: 5.379

8.  Cuprizone-induced oligodendrocyte loss and demyelination impairs recording performance of chronically implanted neural interfaces.

Authors:  Steven M Wellman; Kelly Guzman; Kevin C Stieger; Lauren E Brink; Sadhana Sridhar; Mitchell T Dubaniewicz; Lehong Li; Franca Cambi; Takashi D Y Kozai
Journal:  Biomaterials       Date:  2020-02-06       Impact factor: 12.479

9.  Neuromodulation Management of Chronic Neuropathic Pain in The Central Nervous system.

Authors:  Kai Yu; Xiaodan Niu; Bin He
Journal:  Adv Funct Mater       Date:  2020-06-10       Impact factor: 18.808

10.  Neuroadhesive protein coating improves the chronic performance of neuroelectronics in mouse brain.

Authors:  Asiyeh Golabchi; Kevin M Woeppel; Xia Li; Carl F Lagenaur; X Tracy Cui
Journal:  Biosens Bioelectron       Date:  2020-02-18       Impact factor: 10.618

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.