Literature DB >> 20644246

Reduction of neurovascular damage resulting from microelectrode insertion into the cerebral cortex using in vivo two-photon mapping.

T D Y Kozai1, T C Marzullo, F Hooi, N B Langhals, A K Majewska, E B Brown, D R Kipke.   

Abstract

Penetrating neural probe technologies allow investigators to record electrical signals in the brain. The implantation of probes causes acute tissue damage, partially due to vasculature disruption during probe implantation. This trauma can cause abnormal electrophysiological responses and temporary increases in neurotransmitter levels, and perpetuate chronic immune responses. A significant challenge for investigators is to examine neurovascular features below the surface of the brain in vivo. The objective of this study was to investigate localized bleeding resulting from inserting microscale neural probes into the cortex using two-photon microscopy (TPM) and to explore an approach to minimize blood vessel disruption through insertion methods and probe design. 3D TPM images of cortical neurovasculature were obtained from mice and used to select preferred insertion positions for probe insertion to reduce neurovasculature damage. There was an 82.8 +/- 14.3% reduction in neurovascular damage for probes inserted in regions devoid of major (>5 microm) sub-surface vessels. Also, the deviation of surface vessels from the vector normal to the surface as a function of depth and vessel diameter was measured and characterized. 68% of the major vessels were found to deviate less than 49 microm from their surface origin up to a depth of 500 microm. Inserting probes more than 49 microm from major surface vessels can reduce the chances of severing major sub-surface neurovasculature without using TPM.

Entities:  

Mesh:

Year:  2010        PMID: 20644246      PMCID: PMC3164482          DOI: 10.1088/1741-2560/7/4/046011

Source DB:  PubMed          Journal:  J Neural Eng        ISSN: 1741-2552            Impact factor:   5.379


  58 in total

Review 1.  Brain-controlled interfaces: movement restoration with neural prosthetics.

Authors:  Andrew B Schwartz; X Tracy Cui; Douglas J Weber; Daniel W Moran
Journal:  Neuron       Date:  2006-10-05       Impact factor: 17.173

2.  Spatiotemporal pH dynamics following insertion of neural microelectrode arrays.

Authors:  Matthew D Johnson; Olivia E Kao; Daryl R Kipke
Journal:  J Neurosci Methods       Date:  2006-11-03       Impact factor: 2.390

3.  Morphometry of the human cerebral cortex microcirculation: general characteristics and space-related profiles.

Authors:  Frederic Lauwers; Francis Cassot; Valerie Lauwers-Cances; Prasanna Puwanarajah; Henri Duvernoy
Journal:  Neuroimage       Date:  2007-09-21       Impact factor: 6.556

4.  Three-dimensional cerebral vasculature of the CBA mouse brain: a magnetic resonance imaging and micro computed tomography study.

Authors:  A Dorr; J G Sled; N Kabani
Journal:  Neuroimage       Date:  2007-01-23       Impact factor: 6.556

5.  Neural probe design for reduced tissue encapsulation in CNS.

Authors:  John P Seymour; Daryl R Kipke
Journal:  Biomaterials       Date:  2007-04-05       Impact factor: 12.479

6.  Mechanical properties of dura mater from the rat brain and spinal cord.

Authors:  Jason T Maikos; Ragi A I Elias; David I Shreiber
Journal:  J Neurotrauma       Date:  2008-01       Impact factor: 5.269

7.  Functional studies in living animals using multiphoton microscopy.

Authors:  Kenneth William Dunn; Timothy Alan Sutton
Journal:  ILAR J       Date:  2008

8.  Insertion shuttle with carboxyl terminated self-assembled monolayer coatings for implanting flexible polymer neural probes in the brain.

Authors:  Takashi D Yoshida Kozai; Daryl R Kipke
Journal:  J Neurosci Methods       Date:  2009-08-08       Impact factor: 2.390

9.  Correlations of neuronal and microvascular densities in murine cortex revealed by direct counting and colocalization of nuclei and vessels.

Authors:  Philbert S Tsai; John P Kaufhold; Pablo Blinder; Beth Friedman; Patrick J Drew; Harvey J Karten; Patrick D Lyden; David Kleinfeld
Journal:  J Neurosci       Date:  2009-11-18       Impact factor: 6.167

10.  Neural interface dynamics following insertion of hydrous iridium oxide microelectrode arrays.

Authors:  Matthew D Johnson; Nicholas B Langhals; Daryl R Kipke
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2006
View more
  76 in total

1.  Glial responses to implanted electrodes in the brain.

Authors:  Joseph W Salatino; Kip A Ludwig; Takashi D Y Kozai; Erin K Purcell
Journal:  Nat Biomed Eng       Date:  2017-11-10       Impact factor: 25.671

Review 2.  In Vivo Chemical Sensors: Role of Biocompatibility on Performance and Utility.

Authors:  Robert J Soto; Jackson R Hall; Micah D Brown; James B Taylor; Mark H Schoenfisch
Journal:  Anal Chem       Date:  2016-11-21       Impact factor: 6.986

Review 3.  Neurophysiology and neural engineering: a review.

Authors:  Arthur Prochazka
Journal:  J Neurophysiol       Date:  2017-05-31       Impact factor: 2.714

4.  A Materials Roadmap to Functional Neural Interface Design.

Authors:  Steven M Wellman; James R Eles; Kip A Ludwig; John P Seymour; Nicholas J Michelson; William E McFadden; Alberto L Vazquez; Takashi D Y Kozai
Journal:  Adv Funct Mater       Date:  2017-07-19       Impact factor: 18.808

5.  Zwitterionic Polymer Coating Suppresses Microglial Encapsulation to Neural Implants In Vitro and In Vivo.

Authors:  Qianru Yang; Bingchen Wu; James R Eles; Alberto L Vazquez; Takashi D Y Kozai; X Tracy Cui
Journal:  Adv Biosyst       Date:  2020-05-04

6.  Insertion of linear 8.4 μm diameter 16 channel carbon fiber electrode arrays for single unit recordings.

Authors:  Paras R Patel; Kyounghwan Na; Huanan Zhang; Takashi D Y Kozai; Nicholas A Kotov; Euisik Yoon; Cynthia A Chestek
Journal:  J Neural Eng       Date:  2015-06-02       Impact factor: 5.379

7.  Inhibition of the cluster of differentiation 14 innate immunity pathway with IAXO-101 improves chronic microelectrode performance.

Authors:  John K Hermann; Madhumitha Ravikumar; Andrew J Shoffstall; Evon S Ereifej; Kyle M Kovach; Jeremy Chang; Arielle Soffer; Chun Wong; Vishnupriya Srivastava; Patrick Smith; Grace Protasiewicz; Jingle Jiang; Stephen M Selkirk; Robert H Miller; Steven Sidik; Nicholas P Ziats; Dawn M Taylor; Jeffrey R Capadona
Journal:  J Neural Eng       Date:  2018-04       Impact factor: 5.379

8.  Cuprizone-induced oligodendrocyte loss and demyelination impairs recording performance of chronically implanted neural interfaces.

Authors:  Steven M Wellman; Kelly Guzman; Kevin C Stieger; Lauren E Brink; Sadhana Sridhar; Mitchell T Dubaniewicz; Lehong Li; Franca Cambi; Takashi D Y Kozai
Journal:  Biomaterials       Date:  2020-02-06       Impact factor: 12.479

9.  Evaluation of poly(3,4-ethylenedioxythiophene)/carbon nanotube neural electrode coatings for stimulation in the dorsal root ganglion.

Authors:  Christi L Kolarcik; Kasey Catt; Erika Rost; Ingrid N Albrecht; Dennis Bourbeau; Zhanhong Du; Takashi D Y Kozai; Xiliang Luo; Douglas J Weber; X Tracy Cui
Journal:  J Neural Eng       Date:  2014-12-08       Impact factor: 5.379

10.  Neuroadhesive protein coating improves the chronic performance of neuroelectronics in mouse brain.

Authors:  Asiyeh Golabchi; Kevin M Woeppel; Xia Li; Carl F Lagenaur; X Tracy Cui
Journal:  Biosens Bioelectron       Date:  2020-02-18       Impact factor: 10.618

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.