Literature DB >> 28179062

Smartphone assessment of knee flexion compared to radiographic standards.

Matthew J Dietz1, Daniel Sprando2, Andrew E Hanselman3, Michael D Regier4, Benjamin M Frye3.   

Abstract

BACKGROUND: Measuring knee range of motion (ROM) is an important assessment for the outcomes of total knee arthroplasty. Recent technological advances have led to the development and use of accelerometer-based smartphone applications to measure knee ROM. The purpose of this study was to develop, standardize, and validate methods of utilizing smartphone accelerometer technology compared to radiographic standards, visual estimation, and goniometric evaluation.
METHODS: Participants used visual estimation, a long-arm goniometer, and a smartphone accelerometer to determine range of motion of a cadaveric lower extremity; these results were compared to radiographs taken at the same angles.
RESULTS: The optimal smartphone position was determined to be on top of the leg at the distal femur and proximal tibia location. Between methods, it was found that the smartphone and goniometer were comparably reliable in measuring knee flexion (ICC=0.94; 95% CI: 0.91-0.96). Visual estimation was found to be the least reliable method of measurement.
CONCLUSIONS: The results suggested that the smartphone accelerometer was non-inferior when compared to the other measurement techniques, demonstrated similar deviations from radiographic standards, and did not appear to be influenced by the person performing the measurements or the girth of the extremity.
Copyright © 2016 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Accelerometer; Measurement; Motion; Smartphone

Mesh:

Year:  2017        PMID: 28179062      PMCID: PMC5359022          DOI: 10.1016/j.knee.2016.11.014

Source DB:  PubMed          Journal:  Knee        ISSN: 0968-0160            Impact factor:   2.199


  10 in total

1.  Inter and intra-rater reliability of mobile device goniometer in measuring lumbar flexion range of motion.

Authors:  Nilima Bedekar; Mayuri Suryawanshi; Savita Rairikar; Parag Sancheti; Ashok Shyam
Journal:  J Back Musculoskelet Rehabil       Date:  2014       Impact factor: 1.398

Review 2.  Intraclass correlations: uses in assessing rater reliability.

Authors:  P E Shrout; J L Fleiss
Journal:  Psychol Bull       Date:  1979-03       Impact factor: 17.737

3.  The assessment of intraoperative prosthetic knee range of motion using two methods.

Authors:  Matthew S Austin; Elie Ghanem; Ashish Joshi; Rachel Trappler; Javad Parvizi; William J Hozack
Journal:  J Arthroplasty       Date:  2008-04-15       Impact factor: 4.757

4.  Smartphone apps for orthopaedic surgeons.

Authors:  Orrin I Franko
Journal:  Clin Orthop Relat Res       Date:  2011-05-06       Impact factor: 4.176

5.  Reliability of a smartphone-based goniometer for knee joint goniometry.

Authors:  Giorgio Ferriero; Stefano Vercelli; Francesco Sartorio; Susana Muñoz Lasa; Elena Ilieva; Elisa Brigatti; Carolina Ruella; Calogero Foti
Journal:  Int J Rehabil Res       Date:  2013-06       Impact factor: 1.479

6.  Validation of a novel smartphone accelerometer-based knee goniometer.

Authors:  Matthew Ockendon; Robin E Gilbert
Journal:  J Knee Surg       Date:  2012-09       Impact factor: 2.757

Review 7.  Total knee arthroplasty with a novel navigation system within the surgical field.

Authors:  Giles R Scuderi; Michel Fallaha; Vincent Masse; Patrick Lavigne; Louis-Philippe Amiot; Marie-Josee Berthiaume
Journal:  Orthop Clin North Am       Date:  2014-01-16       Impact factor: 2.472

8.  Reliability and validity of goniometric measurements at the knee.

Authors:  P P Gogia; J H Braatz; S J Rose; B J Norton
Journal:  Phys Ther       Date:  1987-02

9.  Measuring flexion in knee arthroplasty patients.

Authors:  John Z Edwards; Kenneth A Greene; Robert S Davis; Mark W Kovacik; Donald A Noe; Michael J Askew
Journal:  J Arthroplasty       Date:  2004-04       Impact factor: 4.757

10.  Estimating risk in Medicare patients with THA: an electronic risk calculator for periprosthetic joint infection and mortality.

Authors:  Kevin J Bozic; Kevin Ong; Edmund Lau; Daniel J Berry; Thomas P Vail; Steven M Kurtz; Harry E Rubash
Journal:  Clin Orthop Relat Res       Date:  2012-11-21       Impact factor: 4.176

  10 in total
  3 in total

1.  A Five-Year Comparative Functional and Clinical Evaluation of Two Contemporary Cruciate-Retaining Knee Implants.

Authors:  Ashok Rajgopal; Kalpana Aggarwal; Sumit Kumar
Journal:  Arthroplast Today       Date:  2020-06-16

2.  Accuracy and reliability of knee goniometry methods.

Authors:  Graeme Ethan Hancock; Tracey Hepworth; Kevin Wembridge
Journal:  J Exp Orthop       Date:  2018-10-19

3.  Optimal position of lipped acetabular liners to improve stability in total hip arthroplasty-an intraoperative in vivo study.

Authors:  Raphael Hau; Joshua Hammeschlag; Christopher Law; Kemble K Wang
Journal:  J Orthop Surg Res       Date:  2018-11-19       Impact factor: 2.359

  3 in total