The assessment of intraoperative prosthetic knee range of motion using two methods.

Matthew S Austin1, Elie Ghanem, Ashish Joshi, Rachel Trappler, Javad Parvizi, William J Hozack.   

Abstract

The commonly used standard goniometer has been shown to underestimate knee flexion. Computer-assisted navigation for total knee arthroplasty offers itself as an alternative method to quantify knee flexion. The goal of our study was to determine the reliability of each instrument in measuring intraoperative range of motion during total knee arthroplasty. We prospectively performed intraoperative measurements using both methods on 99 knees. We assessed the variability between the 2 devices and the confounding effect of body mass index. The mean difference between the goniometric and navigation measurements was significant for flexion, extension, and range of motion. Increasing body mass index accentuated this difference. The goniometric method underestimated flexion measurements as compared to navigation, especially in patients with high body mass index. Our study confirms that navigation is a reliable tool for performing in vivo assessment of range of motion.

Entities:  

Mesh:

Year:  2008        PMID: 18514867     DOI: 10.1016/j.arth.2007.12.011

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  6 in total

1.  Measurement of knee joint motion using digital imaging.

Authors:  Damien Bennett; Brian Hanratty; Neville Thompson; David Beverland
Journal:  Int Orthop       Date:  2008-11-27       Impact factor: 3.075

2.  Dynamic knee behaviour: does the knee deformity change as it is flexed-an assessment and classification with computer navigation.

Authors:  Kamal Deep; Frederic Picard; Joseph Baines
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2016-10-06       Impact factor: 4.342

3.  Measurement of the knee flexion angle with smartphone applications: Which technology is better?

Authors:  Jean-Yves Jenny; Abdullah Bureggah; Yann Diesinger
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2015-02-15       Impact factor: 4.342

4.  Smartphone assessment of knee flexion compared to radiographic standards.

Authors:  Matthew J Dietz; Daniel Sprando; Andrew E Hanselman; Michael D Regier; Benjamin M Frye
Journal:  Knee       Date:  2017-02-05       Impact factor: 2.199

5.  Application of a vibrating device for the prevention of flexion contracture after total knee arthroplasty.

Authors:  Sándor Manó; Judit Pálinkás; János Szabó; Judit T Nagy; Katalin Bakó; Zoltán Csernátony
Journal:  Eur J Orthop Surg Traumatol       Date:  2014-04-29

6.  Is Arthroscopic Transosseous Rotator Cuff Repair Strength Dependent on the Tunnel Angle?

Authors:  Daniel Bronsnick; Andrew Pastor; Dmitriy Peresada; Farid Amirouche; Giovanni Francesco Solitro; Benjamin A Goldberg
Journal:  Orthop J Sports Med       Date:  2019-06-06