Literature DB >> 28155679

The risk of stanford type-A aortic dissection with different tear size and location: a numerical study.

Yue Shi1, Minjia Zhu1, Yu Chang2, Huanyu Qiao3, Yongmin Liu4.   

Abstract

BACKGROUND: This study is to investigate the influence of hemodynamics on Stanford type-A aortic dissection with different tear size and location, to provide some support for the relationships between the risks (rupture, reverse tearing and further tearing) and tear size and location for clinical treatment.
METHODS: Four numerical models of Stanford type-A aortic dissection were established, with different size and location of the tears. The ratio of the area between the entry and re-entry tears(RA) is various within the model; while, the size and the location of the re-entry in the distal descending aorta are fixed. In model A11 and A21, the entry tears are located near the ascending aorta. The RA in these models are 1 and 2, respectively; In the model B11 and B21, the entry tears are located near the proximal descending aorta and the RA in these models are again assigned to 1 and 2, respectively. Then hemodynamics in these models was solved with numerically and the flow patterns and loading distributions were investigated.
RESULTS: The flow velocity of the true lumen in model A21, B21 is lower than that in A11, B11, respectively; the time-averaged wall shear stress (TAWSS) of the false lumen in model A21 and B21 is higher, and for ascending aorta false lumen, A11, A21 are higher than B11, B21, respectively. False lumen intimal wall pressure of A11, A21 are always higher than the true lumen ones.
CONCLUSION: The variation of the RA can significantly affect the dynamics of blood within the aortic dissection. When the entry tear size is larger than the re-entry tear ones, the false lumen, proximal descending aorta and the wall near re-entry tear are prone to cracking. Entry tear location can significantly alter the hemodynamics of aortic dissection as well. When entry tear location is closer to proximal ascending aorta, false lumen continues to expand and compress the true lumen resulting in the true lumen reduction. For proximal ascending aorta, high pressure in false lumen predicts a higher risk of reverse tear.

Entities:  

Keywords:  Hemodynamic; Risk assessment; Stanford type-A aortic dissection

Mesh:

Year:  2016        PMID: 28155679      PMCID: PMC5259983          DOI: 10.1186/s12938-016-0258-y

Source DB:  PubMed          Journal:  Biomed Eng Online        ISSN: 1475-925X            Impact factor:   2.819


  24 in total

1.  Numerical simulation and experimental validation of blood flow in arteries with structured-tree outflow conditions.

Authors:  M S Olufsen; C S Peskin; W Y Kim; E M Pedersen; A Nadim; J Larsen
Journal:  Ann Biomed Eng       Date:  2000 Nov-Dec       Impact factor: 3.934

2.  Spatial comparison between wall shear stress measures and porcine arterial endothelial permeability.

Authors:  Heather A Himburg; Deborah M Grzybowski; Andrew L Hazel; Jeffrey A LaMack; Xue-Mei Li; Morton H Friedman
Journal:  Am J Physiol Heart Circ Physiol       Date:  2004-01-08       Impact factor: 4.733

3.  A mathematical model to predict the in vivo pulsatile drag forces acting on bifurcated stent grafts used in endovascular treatment of abdominal aortic aneurysms (AAA).

Authors:  L Morris; P Delassus; M Walsh; T McGloughlin
Journal:  J Biomech       Date:  2004-07       Impact factor: 2.712

4.  3-D numerical simulation of blood flow through models of the human aorta.

Authors:  L Morris; P Delassus; A Callanan; M Walsh; F Wallis; P Grace; T McGloughlin
Journal:  J Biomech Eng       Date:  2005-10       Impact factor: 2.097

5.  Numerical simulations of the blood flow through vertebral arteries.

Authors:  Krzysztof Jozwik; Damian Obidowski
Journal:  J Biomech       Date:  2009-11-11       Impact factor: 2.712

6.  Color Doppler evaluation of aortic dissection.

Authors:  S Iliceto; N C Nanda; P Rizzon; M C Hsuing; R G Goyal; A Amico; M Sorino
Journal:  Circulation       Date:  1987-04       Impact factor: 29.690

7.  Modeling of flow in a straight stented and nonstented side wall aneurysm model.

Authors:  M Aenis; A P Stancampiano; A K Wakhloo; B B Lieber
Journal:  J Biomech Eng       Date:  1997-05       Impact factor: 2.097

8.  Validation of CFD simulations of cerebral aneurysms with implication of geometric variations.

Authors:  Yiemeng Hoi; Scott H Woodward; Minsuok Kim; Dale B Taulbee; Hui Meng
Journal:  J Biomech Eng       Date:  2006-12       Impact factor: 2.097

9.  A longitudinal study of Type-B aortic dissection and endovascular repair scenarios: computational analyses.

Authors:  Duanduan Chen; Matthias Müller-Eschner; Drosos Kotelis; Dittmar Böckler; Yiannis Ventikos; Hendrik von Tengg-Kobligk
Journal:  Med Eng Phys       Date:  2013-03-22       Impact factor: 2.242

10.  Initial findings and potential applicability of computational simulation of the aorta in acute type B dissection.

Authors:  Zhuo Cheng; Celia Riga; Joyce Chan; Mohammad Hamady; Nigel B Wood; Nicholas J W Cheshire; Yun Xu; Richard G J Gibbs
Journal:  J Vasc Surg       Date:  2013-02       Impact factor: 4.268

View more
  5 in total

1.  Preface: Computational and experimental methods for biological research: cardiovascular diseases and beyond.

Authors:  Dalin Tang; Zhi-Yong Li
Journal:  Biomed Eng Online       Date:  2016-12-28       Impact factor: 2.819

Review 2.  Computational Hemodynamic Modeling of Arterial Aneurysms: A Mini-Review.

Authors:  Sarah N Lipp; Elizabeth E Niedert; Hannah L Cebull; Tyler C Diorio; Jessica L Ma; Sean M Rothenberger; Kimberly A Stevens Boster; Craig J Goergen
Journal:  Front Physiol       Date:  2020-05-12       Impact factor: 4.566

3.  Influence of MRI-based boundary conditions on type B aortic dissection simulations in false lumen with or without abdominal aorta involvement.

Authors:  Dongting Liu; Xuan Wang; Dongliang Zhao; Zhonghua Sun; Jumatay Biekan; Zhaoying Wen; Lei Xu; Jiayi Liu
Journal:  Front Physiol       Date:  2022-09-07       Impact factor: 4.755

4.  The characteristics of distal tears affect false lumen thrombosis rate after thoracic endovascular aortic repair for acute type B dissection.

Authors:  Da Li; Ding Yuan; Liqing Peng; Tinghui Zheng; Yubo Fan
Journal:  Interact Cardiovasc Thorac Surg       Date:  2021-10-29

5.  A case report of unexpected sudden cardiac death due to aortic rupture following laparoscopic appendectomy.

Authors:  Chunghee Joo; Joo-Won Min; Giyong Noh; Jaeho Seo
Journal:  Medicine (Baltimore)       Date:  2018-10       Impact factor: 1.817

  5 in total