Literature DB >> 3829338

Color Doppler evaluation of aortic dissection.

S Iliceto, N C Nanda, P Rizzon, M C Hsuing, R G Goyal, A Amico, M Sorino.   

Abstract

Color Doppler studies were performed in 16 adult patients with proven DeBakey type I and III aortic dissection. Simultaneous opacification of both aortic lumina with oppositely directed flow was noted by color Doppler in at least one aortic segment in 14 of 16 patients (12 type I, two type III). In two patients (one type I, one type III), flow was seen in one lumen only, with clot demonstrated in the other lumen in one of them. Of 12 patients in whom communication between two aortic dissection channels was shown by angiography/surgery, color Doppler correctly identified them in nine patients (four ascending aorta, two aortic arch, and three descending aorta), either by direct visualization of flow moving from one lumen into the other (six patients) or indirectly by analyzing differences in timing of opacification of the two lumina and flow direction (three patients). Also, color Doppler correctly diagnosed aortic regurgitation as severe (aortic regurgitation jet occupying more than 75% of left ventricular outflow) in three patients and moderate in four patients. Color Doppler provides comprehensive evaluation of flow dynamics in aortic dissection.

Entities:  

Mesh:

Year:  1987        PMID: 3829338     DOI: 10.1161/01.cir.75.4.748

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  8 in total

1.  Doppler color flow imaging of common carotid artery dissection.

Authors:  W Steinke; A Schwartz; M Hennerici
Journal:  Neuroradiology       Date:  1990       Impact factor: 2.804

2.  The risk of stanford type-A aortic dissection with different tear size and location: a numerical study.

Authors:  Yue Shi; Minjia Zhu; Yu Chang; Huanyu Qiao; Yongmin Liu
Journal:  Biomed Eng Online       Date:  2016-12-28       Impact factor: 2.819

Review 3.  Echocardiography.

Authors:  J B Chambers; M J Monaghan; G Jackson
Journal:  BMJ       Date:  1988-10-29

Review 4.  Echocardiography in the diagnosis of thoracic aortic pathology.

Authors:  F D Tice; J Kisslo
Journal:  Int J Card Imaging       Date:  1993

5.  Comparison of conventional and transesophageal echocardiography with magnetic resonance imaging for anatomical mapping of thoracic aortic dissection. A dual noninvasive imaging study with anatomical and/or angiographic validation.

Authors:  C A Nienaber; Y von Kodolitsch; C J Brockhoff; D H Koschyk; R P Spielmann
Journal:  Int J Card Imaging       Date:  1994-03

6.  Ambulatory follow-up of aortic dissection: comparison between computed tomography and biplane transesophageal echocardiography.

Authors:  S Maffei; M Baroni; M Terrazzi; M Piacenti; F Paoli; E Camerini; F Verunelli; L Salvatore; A Biagini
Journal:  Int J Card Imaging       Date:  1996-06

Review 7.  Transesophageal echocardiography evaluation of the thoracic aorta.

Authors:  T A Patil; Arno Nierich
Journal:  Ann Card Anaesth       Date:  2016-10

8.  Role of proximal and distal tear size ratio in hemodynamic change of acute type A aortic dissection.

Authors:  Xiaonan Li; Huanyu Qiao; Yue Shi; Jinrong Xue; Tao Bai; Yongmin Liu; Lizhong Sun
Journal:  J Thorac Dis       Date:  2020-06       Impact factor: 2.895

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.