| Literature DB >> 28127399 |
Ariana M Nicolini1, Katherine E McCracken2, Jeong-Yeol Yoon1,2.
Abstract
Since early reports of the recent Zika virus outbreak in May 2015, much has been learned and discussed regarding Zika virus infection and transmission. However, many opportunities still remain for translating these findings into field-ready sensors and diagnostics. In this brief review, we discuss current diagnostic methods, consider the prospects of translating other flavivirus biosensors directly to Zika virus sensing, and look toward the future developments needed for high-sensitivity and high-specificity biosensors to come.Entities:
Keywords: Biosensors; Flaviviruses; Immunoassays; LAMP; RT-PCR; Zika
Year: 2017 PMID: 28127399 PMCID: PMC5260080 DOI: 10.1186/s13036-016-0046-z
Source DB: PubMed Journal: J Biol Eng ISSN: 1754-1611 Impact factor: 4.355
Fig. 1Number of peer-reviewed publications on ZIKV related to novel sensors development, topic reviews and commentaries, molecular biology and virology, and epidemiology or clinical evaluations of Zika cases (as of October 15, 2016). Cumulative publications are presented in 5 year increments until 2015 and 1 year increments between 2015 and 2016 (top). Publications in 2015–2016 are also presented separately by month (bottom)
Fig. 2Flow diagram of gold standard ZIKV detection by patient type and time from onset of symptoms. RT-qPCR detection is typically used in the first 2 weeks of illness and IgM ELISA after the first 2 weeks or when RT-qPCR is negative. PRNT assay should be used as a final test if an ELISA assay returns positive or inconclusive
Fig. 3Assay schematics for ZIKV diagnostics by reverse transcription quantitative real-time polymerase chain reaction (RT-qPCR), IgM antibody capture enzyme-linked immunosorbent assay (MAC-ELISA), and a plaque-reduction neutralization test (PRNT). a In one-step RT-qPCR, a patient sample is thermally cycled in a buffered reagent solution containing ZIKV primers, and the amplified target is identified by fluorescence, typically after 40 cycles. b In MAC-ELISA, human IgM developed in response to ZIKV infection are captured and quantified though antibody interactions and enzymatic conversion of a chromogenic substrate. c In PRNT, patient serum dilutions are mixed with live virus samples and are applied to confluent host cells. Antibodies in infected patients neutralize the virus, leading to a reduction in observable plaques
Laboratory-based ZIKA assay kits
| Assay technique | Manufacturer | Product name |
|---|---|---|
| ELISA | Alpha Diagnostic International | Recombivirus Human Anti-Zika Virus (ZIKV) Envelope protein IgG/IgM ELISA kits |
| CDC | aTrioplex Real-time RT-PCR Assay | |
| CTK Biotech | RecombiLISA Zika IgM ELISA kit | |
| DIA.PRO Diagnostic Bioprobes | ZIKV IgG/M ELISA kits | |
| Euroimmun | Anti-Zika Virus IgG/IgM ELISA kits | |
| InBios International | aZIKV Detect IgM Capture ELISA kit | |
| MyBioSource | Zika Virus IgM (ZV-IgM) ELISA kit | |
| NovaTec Immundiagnostica | NovaLisa Zika Virus IgM μ-capture ELISA kit | |
| Lateral flow assay | Chembio Diagnostic Systems | DPP Zika IgM/IgG assay |
| Immunofluorescence | Euroimmun | Anti-Zika Virus IIFT (IgG or IgM) |
| Multiplex RT-qPCR | Bioneer | AccuPower® ZIKV (DEN, CHIKV) Multiplex Real-time RT-PCR Kit |
| Luminex | azMAP® MultiFLEXTM Zika RNA Assay | |
| SolGent | DiaPlexQTM ZCD Detection Kit | |
| ThermoFisher Scientific | TaqMan Arbovirus Triplex Assay (ZIKV/DENV/CHIKV) | |
| RT-qPCR | Altona Diagnostics | aRealStar Zika Virus RT-PCR Kit 1.0 |
| BioinGentech | HumqPCR-realtimeTM Zika Detection | |
| CDC | Trioplex Real-time RT-PCR Assay | |
| Coyote Bioscience | One Step qPCR Detection kit for the Zika Virus | |
| DaAn Gene | Detection Kit for Zika Virus RNA | |
| Focus Diagnostics | aZika Virus Qualitative Real-Time RT-PCR | |
| Liferiver | Zika Virus Real Time RT-PCR | |
| MyBioSource | Zika, PCR Kit | |
| Roche Molecular Systems | aLightMix® Zika rRT-PCR Test | |
| Siemens Healthcare Diagnostics | aVERSANT® Zika RNA 1.0. Assay (kPCR) | |
| ThermoFisher Scientific | TaqMan Zika Virus Singleplex Assay | |
| US Biological Life Sciences | Genesig Teal-Time PCR Kit for Zika Virus, Easy | |
| Viracor-IBT Laboratories | aZika Virus Real-time RT-PCR Test | |
| WELLS BIO | careGENETM Zika Virus RT-PCR Kit | |
| RT-PCR | ARUP | aZika Virus Detection by RT-PCR Test |
| Vela Diagnostics USA |
a
| |
| Transcription-mediated amplification | Hologic | aAptima® Zika Virus Assay |
aIndicates assays approved under the FDA Emergency Use Authorization (as of October 21, 2016)
Fig. 4a Palm-sized device for point-of-care Ebola detection using RT-PCR and fluorescence detection (reproduced from ref. 33 with permission from American Chemical Society). b Lab-on-a-CD integrated LAMP for foodborne pathogen detection (reproduced from ref. 45 with permission from Elsevier). c Instrument-free RT-LAMP assay and self-contained cassette for point-of-care ZIKV assay (reproduced from ref. 40 with permission from American Chemical Society)
ZIKV biosensors developed in 2016
| Assay technique | Detection mode | Target | Sample matrix | Range of detection | Limit of detection | Sample volume | Assay time | Cost per assay | Ref. |
|---|---|---|---|---|---|---|---|---|---|
| Immunoassay | Impedimetry | NS1 (flaviviruses) | PBS | 10-2000 ng/mL | 3 ng/mL | 40 μL | 30 min | unspecified | [ |
| Capacitance | NS1 (flaviviruses) | PBS | 5-1000 ng/mL | 0.2 ng/mL | |||||
| Immunoassay | Chemiluminescence | E protein (ZIKV) | PBS | 10-105 PFU/mL | 10 PFU/mL | 100 μL | ~2 h | unspecified | [ |
| LAMP | AC susceptometry | NS5 oligonucleotide (ZIKV) | Unspecified | 1-103 aM | 1 aM | 40 μL | <30 min | unspecified | [ |
| NASBA-CRISPR | Colorimetry | RNA (ZIKV) | Serum | 3 fM - 30 pM | 1 fM | 300 μL | ~3 h | $0.10-$1 | [ |
| RT-LAMP | Colorimetry | E protein RNA (ZIKV) | Saliva | 50-5 × 104 PFU/mL | 50-100 PFU/mL | 65 μL | 40 min | ~$2 | [ |
| RT-SIBA | Fluorescence | RNA (ZIKV) | Lysis buffer | 5 × 103-5 × 106 copies/mL | 5000 copies/mL | 2 μL | <30 min | unspecified | [ |
Fig. 5a Biocan diagnostic’s Tell Me Fast™ Zika/Dengue/Chikugunya virus IgG/IgM lateral flow assay (reproduced from www.zikatest.com with permission from Biocan Diagnostics, Inc.). b Chemiluminescent particle immunoassay for ZIKV detection by magnetic separation and ultraviolet fluorescence (reproduced from ref. 68 with permission from the authors)