Literature DB >> 30822687

An ultra-sensitive capacitive microwire sensor for pathogen-specific serum antibody responses.

Lei Wang1, Jessica E Filer2, Meghan M Lorenz3, Charles S Henry4, David S Dandy5, Brian J Geiss6.   

Abstract

Detection of viral infection is commonly performed using serological techniques like the enzyme-linked immunosorbent assay (ELISA) to detect antibody responses. Such assays may also be used to determine the infection phase based on isotype prevalence. However, ELISAs demonstrate limited sensitivity and are difficult to perform at the point of care. Here, we present a novel technique for label-free, rapid detection of ultra-low concentrations of virus specific antibodies. We have developed a simple, robust capacitive biosensor using microwires coated with Zika or Chikungunya virus envelope antigen. With little discernable nonspecific binding, the sensor can detect as few as 10 antibody molecules in a small volume (10 molecules/30 µL) within minutes. It can also be used to rapidly, specifically, and accurately determine the isotype of antigen-specific antibodies. Finally, we demonstrate that anti-Zika virus antibody can be sensitively and specifically detected in dilute mouse serum and can be isotyped using the sensor. Overall, our findings suggest that our microwire sensor platform has the potential to be used as a reliable, sensitive, and inexpensive diagnostic tool to detect immune responses at the point of care.
Copyright © 2019 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Antibody detection; Capacitive affinity biosensor; Isotype; Microwires; Mouse serum; Zika virus

Mesh:

Substances:

Year:  2019        PMID: 30822687      PMCID: PMC6422737          DOI: 10.1016/j.bios.2019.01.040

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  31 in total

1.  Simple and sensitive electrode design for microchip electrophoresis/electrochemistry.

Authors:  Yan Liu; Jonathan A Vickers; Charles S Henry
Journal:  Anal Chem       Date:  2004-03-01       Impact factor: 6.986

2.  Sub-attomolar detection of cholera toxin using a label-free capacitive immunosensor.

Authors:  S Loyprasert; M Hedström; P Thavarungkul; P Kanatharana; B Mattiasson
Journal:  Biosens Bioelectron       Date:  2010-01-25       Impact factor: 10.618

3.  Ultrasensitive detection of HIV-1 p24 antigen using nanofunctionalized surfaces in a capacitive immunosensor.

Authors:  Kosin Teeparuksapun; Martin Hedström; Eric Y Wong; Shixing Tang; Indira K Hewlett; Bo Mattiasson
Journal:  Anal Chem       Date:  2010-10-15       Impact factor: 6.986

4.  A rapid and quantitative assay for measuring antibody-mediated neutralization of West Nile virus infection.

Authors:  Theodore C Pierson; Melissa D Sánchez; Bridget A Puffer; Asim A Ahmed; Brian J Geiss; Laura E Valentine; Louis A Altamura; Michael S Diamond; Robert W Doms
Journal:  Virology       Date:  2005-12-02       Impact factor: 3.616

Review 5.  Diagnostic devices as biomaterials: a review of nucleic acid and protein microarray surface performance issues.

Authors:  Peng Wu; David G Castner; David W Grainger
Journal:  J Biomater Sci Polym Ed       Date:  2008       Impact factor: 3.517

Review 6.  Lateral flow (immuno)assay: its strengths, weaknesses, opportunities and threats. A literature survey.

Authors:  Geertruida A Posthuma-Trumpie; Jakob Korf; Aart van Amerongen
Journal:  Anal Bioanal Chem       Date:  2008-08-13       Impact factor: 4.142

7.  Investigation of microflow reversal by ac electrokinetics in orthogonal electrodes for micropump design.

Authors:  Kai Yang; Jie Wu
Journal:  Biomicrofluidics       Date:  2008-04-04       Impact factor: 2.800

8.  An electrochemical immunoassay for the screening of celiac disease in saliva samples.

Authors:  Gianluca Adornetto; Laura Fabiani; Giulia Volpe; Alessia De Stefano; Sonia Martini; Raffaella Nenna; Federica Lucantoni; Margherita Bonamico; Claudio Tiberti; Danila Moscone
Journal:  Anal Bioanal Chem       Date:  2015-07-14       Impact factor: 4.142

9.  Voltammetric detection of mercury and copper in seawater using a gold microwire electrode.

Authors:  Pascal Salaün; Constant M G van den Berg
Journal:  Anal Chem       Date:  2006-07-15       Impact factor: 6.986

10.  Zika virus infection complicated by Guillain-Barre syndrome--case report, French Polynesia, December 2013.

Authors:  E Oehler; L Watrin; P Larre; I Leparc-Goffart; S Lastere; F Valour; L Baudouin; Hp Mallet; D Musso; F Ghawche
Journal:  Euro Surveill       Date:  2014-03-06
View more
  4 in total

Review 1.  Zika virus serological diagnosis: commercial tests and monoclonal antibodies as tools.

Authors:  Isaura Beatriz Borges Silva; Aldacilene Souza da Silva; Mariana Sequetin Cunha; Aline Diniz Cabral; Kelly Cristina Alves de Oliveira; Elizabeth De Gaspari; Carlos Roberto Prudencio
Journal:  J Venom Anim Toxins Incl Trop Dis       Date:  2020-11-18

2.  Rapid detection of SARS-CoV-2 antibodies using electrochemical impedance-based detector.

Authors:  Mohamed Z Rashed; Jonathan A Kopechek; Mariah C Priddy; Krystal T Hamorsky; Kenneth E Palmer; Nikhil Mittal; Joseph Valdez; Joseph Flynn; Stuart J Williams
Journal:  Biosens Bioelectron       Date:  2020-10-07       Impact factor: 10.618

3.  Synthesis, characterisation and cytotoxicity of gold microwires for ultra-sensitive biosensor development.

Authors:  Nurul Akmal Che Lah; Robert Gray; Sonia Trigueros
Journal:  Microb Cell Fact       Date:  2021-02-17       Impact factor: 5.328

Review 4.  Microfluidic devices for the detection of viruses: aspects of emergency fabrication during the COVID-19 pandemic and other outbreaks.

Authors:  José Alvim Berkenbrock; Rafaela Grecco-Machado; Sven Achenbach
Journal:  Proc Math Phys Eng Sci       Date:  2020-11-04       Impact factor: 2.704

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.