Literature DB >> 28125683

Differences in AMY1 Gene Copy Numbers Derived from Blood, Buccal Cells and Saliva Using Quantitative and Droplet Digital PCR Methods: Flagging the Pitfall.

Delicia Shu Qin Ooi1,2, Verena Ming Hui Tan1,2,3, Siong Gim Ong1,2, Yiong Huak Chan4, Chew Kiat Heng1,2, Yung Seng Lee1,2,3.   

Abstract

INTRODUCTION: The human salivary (AMY1) gene, encoding salivary α-amylase, has variable copy number variants (CNVs) in the human genome. We aimed to determine if real-time quantitative polymerase chain reaction (qPCR) and the more recently available Droplet Digital PCR (ddPCR) can provide a precise quantification of the AMY1 gene copy number in blood, buccal cells and saliva samples derived from the same individual.
METHODS: Seven participants were recruited and DNA was extracted from the blood, buccal cells and saliva samples provided by each participant. Taqman assay real-time qPCR and ddPCR were conducted to quantify AMY1 gene copy numbers. Statistical analysis was carried out to determine the difference in AMY1 gene copy number between the different biological specimens and different assay methods.
RESULTS: We found significant within-individual difference (p<0.01) in AMY1 gene copy number between different biological samples as determined by qPCR. However, there was no significant within-individual difference in AMY1 gene copy number between different biological samples as determined by ddPCR. We also found that AMY1 gene copy number of blood samples were comparable between qPCR and ddPCR, while there is a significant difference (p<0.01) between AMY1 gene copy numbers measured by qPCR and ddPCR for both buccal swab and saliva samples.
CONCLUSIONS: Despite buccal cells and saliva samples being possible sources of DNA, it is pertinent that ddPCR or a single biological sample, preferably blood sample, be used for determining highly polymorphic gene copy numbers like AMY1, due to the large within-individual variability between different biological samples if real time qPCR is employed.

Entities:  

Mesh:

Substances:

Year:  2017        PMID: 28125683      PMCID: PMC5268653          DOI: 10.1371/journal.pone.0170767

Source DB:  PubMed          Journal:  PLoS One        ISSN: 1932-6203            Impact factor:   3.240


Introduction

There has been recent interest in copy number variants (CNVs) of the human salivary amylase (AMY1) gene and its association with obesity via carbohydrate metabolism [1]. AMY1 gene, encoding salivary α-amylase is located in a gene cluster on 1p21. Evolutionary analysis revealed that AMY1 gene was derived from duplication of an ancestral pancreatic amylase gene, with the insertion of a retrovirus sequence that is responsible for tissue-specific expression [2]. The AMY1 gene has a very high sequence identity showing extensive CNV ranging from 2 diploid copies (1 paternal and 1 maternal) to as many as 16 copies [3]. The CNV of AMY1 is strongly correlated with the amount of α-amylase in saliva [3-5]. Low levels of AMY1 CNVs were associated with decreased levels of α-amylase in the saliva and an increased risk of obesity [1], while higher AMY1 copy number was associated with a protective effect against obesity in Mexican children [6]. In addition, females with early-onset obesity were shown to have lower AMY1 copy number and the AMY1 copy number was found to have a significant inverse correlation with body fat percentage and BMI [7]. However, a study by Usher CL et al that examined amylase gene copy number in a cohort of ~3500 obese and lean individuals found no significant association between AMY1 copy number and BMI [8]. It can be postulated that the lack of association may be attributed to the different methodologies employed in assessing AMY1 gene copy number in the samples, as Usher CL et al used ddPCR and computational analysis of whole genome sequencing data [8] which were postulated to have higher precision over qPCR technique used in previous reports which showed correlation between AMY1 copy number and obesity [1]. Until recently, blood samples are the preferred choice of genetic material because they yield sufficient amount of genomic DNA for genetic studies [9]. The quality of genomic DNA from blood is high without contamination of foreign DNA [10]. However, the collection of blood samples may not always be possible. Study subjects may be reluctant to provide blood samples, thereby reducing participating rates. Therefore, less invasive procedures for collecting DNA samples are prevalent. Several studies have found that exfoliated buccal epithelial cells are promising alternative sources of DNA [11-14]. Another alternative source of DNA is whole saliva which is reported to yield DNA with better quality than from buccal swabs [15]. DNA extracted from saliva was reported to have a DNA methylation pattern more similar to that of brain tissues as compared to DNA extracted from blood [16]. Recently, a study also showed that saliva collected using the Oragene kit yielded high quantity and high quality DNA for genetic studies [17]. However, there are still concerns over using DNA extracted from saliva samples or buccal cyto-brushes for genotyping [18, 19] due to possible bacterial contamination which may affect yield and quality of DNA [20]. Furthermore, there is lack of data on whether different biological samples can be used interchangeably for the genotyping of a specific gene of interest, especially for complex genes like the AMY1 gene. The performance of different analytic methods using DNA from buccal cells, saliva and blood for the determination of AMY1 gene copy number is currently unknown. To our knowledge, no study to date has evaluated whether there are within-individual differences in AMY1 gene copy number between DNA derived from blood, buccal cells or saliva. It is logical to assume concordance in gene copy numbers as they are derived from the same person. However, DNA collected using different methods were shown to differ in quality and quantity [18]. Furthermore, differences in copy number variants are observed in different tissues of the same individual [21]. Our original research aim was to determine if AMY1 CNV quantified by TaqMan quantitative polymerase chain reaction (qPCR) is comparable between DNA samples derived from blood, buccal and salivary samples. However, we found unexplained variability and hypothesized that these apparent within-individual differences in AMY1 gene copy number in DNA samples derived from blood, cheek cells and saliva may either be attributed to differences in DNA quality or limitation of the quantitation method. Hence, in this study, we compared the AMY1 gene copy number in DNA derived from blood, cheek cells and saliva of the same individual using qPCR and an alternative quantitation method, droplet digital PCR (ddPCR).

Methods

Participants

Seven male participants were recruited for this study. These participants were part of a research study investigating ethnic differences in glycemic and insulin responses [22, 23]. All participants underwent a screening visit to assess eligibility, which comprised of a health assessment, anthropometric measurements and a health questionnaire (relating to medical history, smoking habits, history of any illness and use of any medications). Those who fulfilled all acceptable criteria (BMI 18.5 to <25kg/m2; age 18–45 years; blood pressure 110–120 / 70–90 mmHg; fasting blood glucose 4–6 mmol/L; not on prescription medication; non-smoking; no genetic or metabolic diseases) were included in the study. This study was approved by the National Healthcare Group Domain Specific Review Board, Singapore. The study was registered at clinicaltrials.gov as NCT01804738 and all participants provided written informed consent prior to their participation in the study.

Blood collection

After an overnight fast, 300μL of capillary blood (obtained from finger pricks) was collected into Microvette® capillary blood collection tubes treated with di Potassium EDTA (CB 300 K2E, Sarstedt, Germany) and kept on ice immediately. The blood samples were transferred and stored at −80°C until DNA extraction [23].

Buccal cells

For the collection of buccal cells, participants were asked to thoroughly rinse out their mouth twice with water. Buccal cells were collected using sterile foam-tip buccal cell collection swabs (Catch-AllTM Sample Collection Swab, Epicentre, Madison, WI, USA) by rolling the collection swab firmly on the inside of the cheek for approximately 20 times on each side, making certain to move the swab over the entire cheek. The swab samples were air dried for 30 minutes at room temperature and then stored in original packaging at -80°C until DNA extraction.

Saliva

In preparation for saliva collection, participants were instructed to empty their mouths by swallowing all saliva and to rinse their mouth thoroughly with water in order to reduce bacteria, fungi and potential food remnants [9]. Whole saliva was collected using Oragene® DNA self-collection kit (DNA Genotek, Ottawa, ON, Canada). Participants were asked to deposit approximately 2 ml saliva through the funnel into the collection tube until the amount of liquid saliva (excluding bubbles) reaches the fill line. When an adequate sample was collected, the funnel lid was then closed firmly. The collection tube was designed so that stabilizing liquid that is attached to the lid mixes with the saliva when the funnel cap is securely fastened. This starts the initial phase of DNA isolation and stabilizes the saliva sample for long-term storage [24]. Saliva samples were stored at 4°C until DNA extraction.

DNA extraction

DNA was extracted from whole blood using QIAamp® DNA Mini Kit (Qiagen, Netherlands) as described by the manufacturer. For buccal cells, DNA was also extracted using QIAamp® DNA Mini Kit (Qiagen, Netherlands), modified for the extraction of DNA from buccal swabs. DNA was extracted from the saliva samples using the Oragene kit (DNA Genotek, Ottawa, ON, Canada) as described by the manufacturer. All extracted DNA samples were quantified and stored at -20°C until analysis.

Quantification of DNA

The concentration of DNA sample was measured using the absorbance method (NanoDrop 1000 v3.7.1, Thermo Scientific). Absorbance of ultraviolet light at wavelengths of 260 nm and 280 nm were used to calculate the optical density (OD) 260/280 ratio. These values are used to compare the ratio of nucleic acid concentration in the sample (OD 260 nm) to that of protein and organic contaminants (OD 280 nm). A ratio of 1.8 was considered ideal for the OD 260/280 ratio, indicating minimal protein and organic contamination. The average DNA concentration was taken from 2 readings. All DNA samples were diluted with nuclease free water and the concentration was verified by Nanodrop.

Quantitative polymerase chain reaction (qPCR) for the AMY1 gene

The qPCR method used to determine diploid AMY1 gene copy numbers was adapted from previously published work [4]. The primers and probes of the TaqMan qPCR assay employed in our analyses specifically target a region within exon 1 of the human AMY1 gene, which is absent in the AMYP1 pseudogene, therefore ensuring specificity of the qPCR assay for AMY1. Briefly, each reaction consisted of 10ul of TaqMan Genotyping Master Mix (Applied Biosystems, Foster City, CA), 1ul of TaqMan Copy Number Assay specific for human AMY1 (Hs07226362-FAM), 1ul of RNAse P reference assay (44003328-VIC), 4ul of DNA (5ng/ul) and 4 ul of nuclease free water. The samples were run in quadruplicates on ABI Prism 7500 Real-Time PCR System (Applied Biosystems). Each individual’s blood, buccal cells and saliva DNA were present in the same plate. The study samples were analyzed using Copy Caller Software v2.0 (Applied Biosystems). AMY1 diploid copy number was estimated using a standard curve constructed from a reference DNA sample NA18972 (Coriell Cell Repositories, Camden, NJ) previously determined to have 14 diploid copies of AMY1 by qPCR and Fiber FISH [3, 25].

Droplet digital PCR (ddPCR) for AMY1 gene copy number analysis

Copy number of the AMY1 gene was determined using the QX200 Droplet Digital PCR (ddPCR) System (Bio-Rad Laboratories, Hercules, CA) according to the manufacturer's instructions. Briefly, each reaction consisted of 11μl ddPCR Supermix for probes (no UTP), 1μl of human AMY1 assay (dHsaCP1000594: 900nM primers and 250nM FAM probe), 1μl of AP3B1 assay (dHsaCP1000001: 900nM primers and 250nM HEX probe), 1μl HaeIII restriction enzyme (3U/μl), 6μl of nuclease free water, and 2μl of DNA (10ng/μl). 20μl of each reaction was transferred to a droplet generation cartridge and 70μl of Droplet Generation Oil was added. Droplets generated with QX200 Droplet Generator (~40ul) were loaded into a clean 96-well PCR plate and the plate was sealed with foil seal using PX1 plate sealer. PCR amplification was performed in a C1000 Touch Deep Well PCR System with the following conditions: 10 minutes at 95°C, 40 cycles of 94°C for 30 seconds and 60°C for 60 seconds with ramp rate of ~2°C/second followed by 98°C for 10minutes with ramp rate of ~1°C/second. Droplets were read in a QX200 Droplet Reader and analysis was performed using QuantaSoft v1.6.6.0320 (Bio-Rad Laboratories). A negative control (water) and a sample known to have 14 diploid copies of AMY1 gene (NA18972, Coriell Cell Repositories, Canden, NJ) were included in the run. Study samples were analyzed in triplicates.

Statistical analysis

Data was presented as mean ± standard deviation (SD). We performed ANOVA to compare the difference in AMY1 gene copy number between blood, buccal swab and saliva samples from each subject. Post-hoc bonferroni adjustment was applied for ANOVA analysis. Paired Student’s t-test was used to determine the difference in AMY1 gene copy number between qPCR and ddPCR in blood, buccal swab and saliva respectively. A p-value of <0.05 was considered statistically significant. Statistical analyses were conducted using SPSS version 23.0 (SPSS Inc., Chicago, IL, USA).

Results

Quantification of DNA extracted from blood, buccal swab and saliva

The quantity and purity of DNA measured by absorbance method (NanoDrop) are shown in . The estimated amount of DNA extracted from 200 μl blood samples varied between 45.7 to 150.3ng/μl with a mean of 72.7 ng/μl, from 1 buccal swab between 20.1 to 83.6 ng/μl with a mean of 48.3 ng/μl, and from 500 μl Oragene saliva samples between 50.0 to 453.5 ng/μl with a mean of 227.2 ng/μl. The quality of DNA obtained was assessed by the ratio of absorbance at 260 nm and 280 nm. The mean values of the optical density 260/280 ratios were 1.90, 1.92 and 1.89 for genomic DNA purified from blood, buccal swab and saliva respectively. Data are presented as mean ± SD

Determination of AMY1 gene copy number by qPCR

ANOVA analysis was used to compare the difference in AMY1 gene copy number between DNA samples extracted from blood, buccal swab and saliva of each subject. By the qPCR method, the average AMY1 gene copy number in the 7 subjects were 7 (range: 6–8) in blood samples, 10 (range: 5–15) in buccal swab samples and 5 (range: 3–7) in saliva samples. In each of the 7 subjects whose DNA samples were analyzed using qPCR, there was at least one significant difference between the different biological samples (either blood vs. buccal swab, blood vs. saliva or buccal swab vs. saliva) with p-value<0.01 after bonferroni adjustment (.

Determination of AMY1 gene copy number by qPCR.

1–7 represents each of the 7 subjects recruited for this study, 8 represents the positive control known to have 14 diploid copies of AMY1 gene. The bars represent the different DNA samples extracted from blood, buccal swab and saliva of each individual. * denotes significant difference of p<0.01 (after bonferroni adjustment) between the different biological samples in each subject using ANOVA analysis.

Determination of AMY1 gene copy number by ddPCR

The AMY1 gene copy number as determined by ddPCR is comparable between the different biological specimens in each subject. The average AMY1 gene copy number in the 7 subjects were 8 (range: 6–10) in blood samples, 8 (6–10) in buccal swab samples and 8 (range: 6–10) in saliva samples. Although subject 5 and 7 demonstrated one copy less in their buccal swab samples compared to their blood and salivary samples, there was no significant difference (p>0.05) in AMY1 gene copy number between the different biological samples obtained from the same subject when analyzed by ddPCR (.

Determination of AMY1 gene copy number by ddPCR.

1–7 represents each of the 7 subjects recruited for this study, 8 represents the positive control known to have 14 diploid copies of AMY1 gene. The bars represent the different DNA samples extracted from blood, buccal swab and saliva of each individual.

Comparison of AMY1 gene copy number between qPCR and ddPCR

We compared AMY1 gene copy number between qPCR and ddPCR in each type of biological sample using paired Student t-test analysis. The average AMY1 gene copy number in the blood samples were 7 (range: 6–8) as determined by qPCR and 8 (range: 6–10) as determined by ddPCR. Although AMY1 gene copy number in the blood DNA as determined by ddPCR is generally 1–2 copies higher as compared to qPCR, there was no statistically significant difference in AMY1 gene copy number for blood DNA samples analyzed by qPCR and ddPCR in each of the 7 subjects using paired Student’s t test as shown in .

Comparison of AMY1 gene copy number determined by qPCR and ddPCR in different biological samples.

1–7 represents each of the 7 subjects recruited for this study, 8 represents the positive control known to have 14 diploid copy number of AMY1 gene. The bars represent the 2 different methods used to determine AMY1 gene copy number in the samples (qPCR and ddPCR). A: Comparison of AMY1 gene copy number in blood. B: Comparison of AMY1 gene copy number in buccal swab. C: Comparison of AMY1 gene copy number in saliva. * denotes significant difference of p<0.01 between qPCR and ddPCR for each type of biological sample after paired Student’s t test analysis. The average AMY1 gene copy number in the buccal swab samples were 10 (range: 5–15) as determined by qPCR and 8 (range: 6–10) as determined by ddPCR. * denotes there was a significant difference (p<0.01) in the AMY1 gene copy number for buccal swab samples determined by qPCR and ddPCR in 4 out of 7 subjects (. The average AMY1 gene copy number in the buccal swab samples were 5 (range: 3–7) as determined by qPCR and 8 (range: 6–10) as determined by ddPCR. There was a significant difference (p<0.01) in the AMY1 gene copy number for buccal swab samples determined by qPCR and ddPCR in 6 out of 7 subjects as denoted by * (.

Discussion and Conclusions

Genetic studies often require the recruitment of large number of participants and ascertainment of DNA samples. Hence, collection methods that do not unduly burden study participants are integral to improving participating rates for genetic epidemiologic studies. In addition to the common method of extracting DNA from blood samples obtained through venipuncture, other non-invasive sampling methods like extracting DNA from saliva and buccal cells have been introduced and used in other studies [13, 16, 26]. In this study, we were able to obtain high quality DNA of adequate yield for genotyping from the three different biological samples namely blood, buccal cells and saliva. We found the mean DNA yield from saliva to be the highest, followed by blood then buccal cells (). This may be attributed to the use of 500ul of saliva as compared to only 200ul of blood and a single buccal swab for DNA extraction. Nonetheless, our results showed that blood, buccal cell and saliva samples yielded good quality DNA for downstream qPCR applications as their OD260/280 values were close to the ideal value of 1.8, indicating minimal protein and organic contamination [26]. Our results showed significant within-individual variability in AMY1 gene copy number between different biological samples as determined by real-time qPCR (). This has implications on studies using real-time qPCR and different biological samples for genotyping copy number of highly polymorphic genes such as AMY1 which is reported to have CNV ranging from 2 to 16 copies [1]. In contrast, there was no significant within-individual variability in AMY1 gene copy number between the different biological samples as determined by ddPCR ( This suggested that ddPCR which was previously shown to be a more sensitive method in the absolute quantification of gene copy number with a lower level of uncertainty (<5%) [27, 28], may be a better method for analyzing highly polymorphic genes such as AMY1 in different biological samples obtained from the same individual. In addition, we compared the AMY1 gene copy number in each biological sample (blood, buccal swab and saliva) between qPCR and ddPCR. Although the AMY1 gene copy number in blood samples showed a consistent 1–2 copies over-read between qPCR and ddPCR, AMY1 gene copy number in blood showed no statistically significant difference between qPCR and ddPCR (. However, there was a significant difference in AMY1 gene copy number in both buccal swab ( and saliva samples ( between qPCR and ddPCR. The inconsistent data between the two quantification methods demonstrated that DNA from buccal cells and saliva may not be good alternatives to blood when genotyping for genes with highly variable CNVs. Previous studies showed that buccal swabs and saliva contained only 11% [13] and 68% [29] human DNA due to bacterial contamination [20]. Hence, the decreased concentration of human DNA in buccal swab and saliva samples are likely to have affected the amplification efficiency in qPCR [30]. The event counts which may be an indirect measure of DNA quantity in ddPCR also differed between the different sample types but did not significantly affect the consistency of AMY1 gene copy number detection (. We recognized several limitations for this study. The concentration and quality of extracted DNA was measured using NanoDrop spectrophotometry which is a less sensitive quantification method as it is not able to detect DNA fragmentation [31]. However, we ran a 1% gel electrophoresis to check for DNA degradation in samples extracted from blood, saliva and buccal swab of all 7 subjects as shown in A distinct band with minimal DNA degradation was observed in all blood and saliva samples. DNA from buccal swab samples showed a greater degree of degradation and only a faint band was observed due to low DNA concentration. Although the presence of bacterial contamination will reduce the actual concentration of human DNA used in qPCR and may contribute to the difference in AMY1 copy number between the different biological samples, we did not measure the amount of bacterial DNA due to limited amount of samples [20]. The event counts in ddPCR and gel electrophoresis indicated that there is a difference in DNA quality and quantity between the sample types. This difference did not significantly affect the ddPCR detection of AMY1 gene copy number between the sample types but it may have affected amplification efficiency in qPCR, hence causing the significant difference in AMY1 gene copy number detected by qPCR. Therefore, we have showed that ddPCR is a more sensitive method that is independent of bacterial contamination and is able to detect consistent AMY1 copy number across different biological samples. In addition, we analyzed AMY1 gene copy number in diluted DNA samples (20ng, 40ng, 80ng) extracted from blood and saliva of one subject using qPCR. The blood DNA showed a fairly consistent AMY1 gene copy number across the diluted samples but we were only able to determine AMY1 gene copy number from the saliva DNA at a higher concentration of 80ng and the detected gene copy number was comparable to that as determined in 80ng of blood DNA (. On contrary, diluted DNA (10ng, 20ng) from saliva, buccal swab and blood samples of the same subject showed no significant difference in AMY1 gene copy number when analyzed using ddPCR (. These results demonstrated that qPCR analysis of AMY1 gene copy number is affected by concentration of target DNA. However, a larger sample size and inclusion of more serial dilution of samples will be required to validate these preliminary data. Another limitation of our study is the small sample size (n = 7) which did not permit us to examine ethnic and age differences that were suggested to affect the yield of DNA collection methods [13, 32]. Though we were able to detect a significant difference in AMY1 gene copy number between the different biological specimens and different quantification methods within our small sample size, a larger sample will enable us to validate our findings. In conclusion, our findings suggested that the determination of AMY1 gene copy number is dependent on the type of biological sample and the sensitivity of the type of assay used for copy number analysis. Despite buccal cells and saliva samples being good alternatives to blood samples to obtain high quality genomic DNA, it is pertinent that a single biological sample be used for determining AMY1 gene copy numbers due to the large within-individual variability between different biological samples especially when using qPCR. Our data showed that DNA extracted from blood is the preferred biological sample for copy number analysis and ddPCR appeared to be more precise than qPCR method in determining AMY1 copy number with less variability across different biological samples from the same individual. This should also be applicable in the determination of other genes with highly variable copy numbers.

Agarose gel (1%) electrophoresis of subjects’ DNA samples.

The degree of DNA degradation in the samples was analyzed by gel electrophoresis. Approximately 500ng of each DNA sample extracted from blood, buccal swab and saliva of all 7 subjects were ran at 70V on a 1% agarose gel. *denotes DNA extracted from blood, # denotes DNA extracted from buccal swab, + denotes DNA extracted from saliva and B denotes a missing buccal swab DNA sample from one of the subjects. (EPS) Click here for additional data file.

Comparison of AMY1 gene copy number in blood and saliva samples using qPCR.

We carried out serial dilution on DNA extracted from blood and saliva samples of one subject. Taqman qPCR as described in the methods section of the manuscript was performed to analyze the AMY1 gene copy number in 20ng, 40ng and 80ng of each type of DNA sample. (EPS) Click here for additional data file.

Comparison of AMY1 gene copy number in blood, buccal swab and saliva samples using ddPCR.

We carried out serial dilution on DNA extracted from blood, buccal swab and saliva samples of one subject. Droplet digital PCR (ddPCR) as described in the methods section of the manuscript was performed to analyze the AMY1 gene copy number in 10ng and 20ng of each type of DNA sample. (EPS) Click here for additional data file.

Event counts for different biological samples used in ddPCR.

The table shows the average accepted droplets (average event counts) in the blood DNA, saliva DNA and buccal DNA of the 7 subjects as analyzed by ddPCR (described in methods section of the manuscript). The average accepted droplets consist of average positive and negative AMY1 droplets where positive droplets are droplets above threshold level and negative droplets are droplets below threshold level. AP3B1 is consistently present at 2 copies in the genome so it was chosen as a reference assay for normalization. Although the average accepted droplets differed between blood DNA, saliva DNA and buccal DNA, the average ratio of AMY1 to AP3B1 copies per 20ul well was fairly consistent in all 3 types of samples. (EPS) Click here for additional data file.
Table 1

Comparison of DNA yield and quality according to DNA collection method.

Method of DNA collectionBloodBuccal cells (swabs)Saliva
Amount of sample used200 μlRange1 swabRange500 μlRange
DNA concentration (ng/ μl)72.7 ± 35.545.7–150.348.3 ± 20.120.1–83.6227.2 ± 159.050.0–453.5
Optical density 260/280 nm ratio1.90 ± 0.051.83–1.961.92 ± 0.061.84–2.001.89 ± 0.051.80–1.94

Data are presented as mean ± SD

  31 in total

1.  Evaluation of quality of DNA extracted from buccal swabs for microarray based genotyping.

Authors:  Alex Livy; Sayhean Lye; Chahil K Jagdish; Nurul Hanis; Velapasamy Sharmila; Lian Wee Ler; Bagali Pramod
Journal:  Indian J Clin Biochem       Date:  2011-08-23

2.  Feasibility of collecting buccal cell DNA by mail in a cohort study.

Authors:  L Le Marchand; A Lum-Jones; B Saltzman; V Visaya; A M Nomura; L N Kolonel
Journal:  Cancer Epidemiol Biomarkers Prev       Date:  2001-06       Impact factor: 4.254

3.  Diet and the evolution of human amylase gene copy number variation.

Authors:  George H Perry; Nathaniel J Dominy; Katrina G Claw; Arthur S Lee; Heike Fiegler; Richard Redon; John Werner; Fernando A Villanea; Joanna L Mountain; Rajeev Misra; Nigel P Carter; Charles Lee; Anne C Stone
Journal:  Nat Genet       Date:  2007-09-09       Impact factor: 38.330

4.  Individual differences in AMY1 gene copy number, salivary α-amylase levels, and the perception of oral starch.

Authors:  Abigail L Mandel; Catherine Peyrot des Gachons; Kimberly L Plank; Suzanne Alarcon; Paul A S Breslin
Journal:  PLoS One       Date:  2010-10-13       Impact factor: 3.240

5.  Comparison of methods for collection of DNA samples by mail in the Black Women's Health Study.

Authors:  Yvette C Cozier; Julie R Palmer; Lynn Rosenberg
Journal:  Ann Epidemiol       Date:  2004-02       Impact factor: 3.797

6.  Quality of DNA extracted from saliva samples collected with the Oragene™ DNA self-collection kit.

Authors:  Ana P Nunes; Isabel O Oliveira; Betânia R Santos; Cristini Millech; Liziane P Silva; David A González; Pedro C Hallal; Ana M B Menezes; Cora L Araújo; Fernando C Barros
Journal:  BMC Med Res Methodol       Date:  2012-05-04       Impact factor: 4.615

7.  Saliva samples are a viable alternative to blood samples as a source of DNA for high throughput genotyping.

Authors:  Jean E Abraham; Mel J Maranian; Inmaculada Spiteri; Roslin Russell; Susan Ingle; Craig Luccarini; Helena M Earl; Paul P D Pharoah; Alison M Dunning; Carlos Caldas
Journal:  BMC Med Genomics       Date:  2012-05-30       Impact factor: 3.063

8.  High-throughput droplet digital PCR system for absolute quantitation of DNA copy number.

Authors:  Benjamin J Hindson; Kevin D Ness; Donald A Masquelier; Phillip Belgrader; Nicholas J Heredia; Anthony J Makarewicz; Isaac J Bright; Michael Y Lucero; Amy L Hiddessen; Tina C Legler; Tyler K Kitano; Michael R Hodel; Jonathan F Petersen; Paul W Wyatt; Erin R Steenblock; Pallavi H Shah; Luc J Bousse; Camille B Troup; Jeffrey C Mellen; Dean K Wittmann; Nicholas G Erndt; Thomas H Cauley; Ryan T Koehler; Austin P So; Simant Dube; Klint A Rose; Luz Montesclaros; Shenglong Wang; David P Stumbo; Shawn P Hodges; Steven Romine; Fred P Milanovich; Helen E White; John F Regan; George A Karlin-Neumann; Christopher M Hindson; Serge Saxonov; Bill W Colston
Journal:  Anal Chem       Date:  2011-10-28       Impact factor: 6.986

9.  Low Copy Number of the AMY1 Locus Is Associated with Early-Onset Female Obesity in Finland.

Authors:  Heli Viljakainen; Johanna C Andersson-Assarsson; Miriam Armenio; Minna Pekkinen; Maria Pettersson; Helena Valta; Marita Lipsanen-Nyman; Outi Mäkitie; Anna Lindstrand
Journal:  PLoS One       Date:  2015-07-01       Impact factor: 3.240

10.  Structural forms of the human amylase locus and their relationships to SNPs, haplotypes and obesity.

Authors:  Christina L Usher; Robert E Handsaker; Tõnu Esko; Marcus A Tuke; Michael N Weedon; Alex R Hastie; Han Cao; Jennifer E Moon; Seva Kashin; Christian Fuchsberger; Andres Metspalu; Carlos N Pato; Michele T Pato; Mark I McCarthy; Michael Boehnke; David M Altshuler; Timothy M Frayling; Joel N Hirschhorn; Steven A McCarroll
Journal:  Nat Genet       Date:  2015-06-22       Impact factor: 38.330

View more
  4 in total

1.  The Effectiveness of ddPCR for Detection of Point Mutations in Poor-Quality Saliva Samples.

Authors:  Petra Riedlova; Dagmar Kramna; Silvie Ostrizkova; Hana Tomaskova; Vitezslav Jirik
Journal:  Healthcare (Basel)       Date:  2022-05-20

2.  Copy Number Variation of the Salivary Amylase Gene and Glucose Metabolism in Healthy Young Japanese Women.

Authors:  Ryoko Higuchi; Taizo Iwane; Ayaka Iida; Kei Nakajima
Journal:  J Clin Med Res       Date:  2020-03-02

3.  High plasma salivary α-amylase, but not high AMY1 copy number, associated with low obesity rate in Qatari adults: cross-sectional study.

Authors:  Neyla Al-Akl; Richard I Thompson; Abdelilah Arredouani
Journal:  Sci Rep       Date:  2020-10-21       Impact factor: 4.379

4.  Development and Evaluation of a Droplet Digital PCR Assay for 8p23 β-Defensin Cluster Copy Number Determination.

Authors:  Tingting Wen; Xianghong Zhang; Christoph Lippuner; Marcel Schiff; Frank Stuber
Journal:  Mol Diagn Ther       Date:  2021-07-29       Impact factor: 4.074

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.