Literature DB >> 28124225

Feasibility of automated titration of vasopressor infusions using a novel closed-loop controller.

Joseph Rinehart1, Michael Ma2, Michael-David Calderon2, Maxime Cannesson3.   

Abstract

Blood pressure management is a central concern in critical care patients. For a variety of reasons, titration of vasopressor infusions may be an ideal use-case for computer assistance. Using our previous experience gained in the bench-to-bedside development of a computer-assisted fluid management system, we have developed a novel controller for this purpose. The aim of this preliminary study was to assess the feasibility of using this controller in simulated patients to maintain a target blood pressure in both stable and variable blood-pressure scenarios. We tested the controller in two sets of simulation scenarios: one with stable underlying blood pressure and a second with variable underlying blood pressure. In addition, in the variable phase of the study, we tested infusion-line delays of 8-60 s. The primary outcome for both testing conditions (stable and variable) was % case time in target range. We determined a priori that acceptable performance on the first phase of the protocol would require greater than 95% case-time in-target given the simple nature of the protocol, and for the second phase of the study 80% or greater given the erratic nature of the blood pressure changes taking place. 250 distinct cases for each simulation condition, both managed and unmanaged, were run over 4 days. In the stable hemodynamic conditions, the unmanaged group had an MAP of 57.5 ± 4.6 mmHg and spent only 5.6% of case time in-target. The managed group had an MAP of 70.3 ± 2.6 and spent a total of 99.5% of case time in-target (p < 0.00001 for both comparisons between groups). In the variable hemodynamic conditions, the unmanaged group had an MAP of 53.1 ± 5.0 mmHg and spent 0% of case time in-target. The managed group had an MAP of 70.5 ± 3.2 mmHg (p < 0.00001 compared to unmanaged group) and spent 88.6% of case time in-target (p < 0.00001 compared to unmanaged group), with 6.4% of case time over and 5.1% of case time under target. Increasing infusion lag increased coefficient of variation by about 10% per 15 s of lag (p = 0.001). This study demonstrated that this novel controller for vasopressor administration is able to main a target mean arterial pressure in a simulated physiologic model in the face of random disturbances and infusion-line lag.

Entities:  

Keywords:  Automated titration; Blood-pressure management; Closed-loop; Sepsis management; Vasopressor

Mesh:

Substances:

Year:  2017        PMID: 28124225     DOI: 10.1007/s10877-017-9981-6

Source DB:  PubMed          Journal:  J Clin Monit Comput        ISSN: 1387-1307            Impact factor:   2.502


  12 in total

1.  Closed-loop fluid resuscitation: robustness against weight and cardiac contractility variations.

Authors:  Joseph Rinehart; Christine Lee; Maxime Cannesson; Guy Dumont
Journal:  Anesth Analg       Date:  2013-11       Impact factor: 5.108

Review 2.  Closed-loop pharmacology in anesthesia and critical care: benefits and limitations.

Authors:  Joseph Rinehart; Cecilia Canales
Journal:  Int Anesthesiol Clin       Date:  2015

3.  High versus low blood-pressure target in patients with septic shock.

Authors:  Pierre Asfar; Ferhat Meziani; Jean-François Hamel; Fabien Grelon; Bruno Megarbane; Nadia Anguel; Jean-Paul Mira; Pierre-François Dequin; Soizic Gergaud; Nicolas Weiss; François Legay; Yves Le Tulzo; Marie Conrad; René Robert; Frédéric Gonzalez; Christophe Guitton; Fabienne Tamion; Jean-Marie Tonnelier; Pierre Guezennec; Thierry Van Der Linden; Antoine Vieillard-Baron; Eric Mariotte; Gaël Pradel; Olivier Lesieur; Jean-Damien Ricard; Fabien Hervé; Damien du Cheyron; Claude Guerin; Alain Mercat; Jean-Louis Teboul; Peter Radermacher
Journal:  N Engl J Med       Date:  2014-03-18       Impact factor: 91.245

Review 4.  Review article: closed-loop systems in anesthesia: is there a potential for closed-loop fluid management and hemodynamic optimization?

Authors:  Joseph Rinehart; Ngai Liu; Brenton Alexander; Maxime Cannesson
Journal:  Anesth Analg       Date:  2011-09-29       Impact factor: 5.108

Review 5.  Should we target blood pressure in sepsis?

Authors:  Jukka Takala
Journal:  Crit Care Med       Date:  2010-10       Impact factor: 7.598

Review 6.  Closed loop insulin delivery in diabetes.

Authors:  Tadej Battelino; Jasna Šuput Omladič; Moshe Phillip
Journal:  Best Pract Res Clin Endocrinol Metab       Date:  2015-03-10       Impact factor: 4.690

7.  A physiologically based, recirculatory model of the kinetics and dynamics of propofol in man.

Authors:  Richard N Upton; Guy Ludbrook
Journal:  Anesthesiology       Date:  2005-08       Impact factor: 7.892

8.  Is there opportunity for automated decision-support and closed-loop control in ICU patients receiving vasopressor infusion?

Authors:  Ramin Bighamian; Cal Rubbo; Jill E Thorsen; Andrew T Reisner
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2014

9.  Evaluation of a novel closed-loop fluid-administration system based on dynamic predictors of fluid responsiveness: an in silico simulation study.

Authors:  Joseph Rinehart; Brenton Alexander; Yannick Le Manach; Christoph Hofer; Benoit Tavernier; Zeev N Kain; Maxime Cannesson
Journal:  Crit Care       Date:  2011-11-23       Impact factor: 9.097

10.  Personalizing blood pressure management in septic shock.

Authors:  Ryotaro Kato; Michael R Pinsky
Journal:  Ann Intensive Care       Date:  2015-11-16       Impact factor: 6.925

View more
  14 in total

1.  Closed-loop vasopressor control: in-silico study of robustness against pharmacodynamic variability.

Authors:  Joseph Rinehart; Alexandre Joosten; Michael Ma; Michael-David Calderon; Maxime Cannesson
Journal:  J Clin Monit Comput       Date:  2018-12-11       Impact factor: 2.502

2.  The future of intraoperative blood pressure management.

Authors:  Frederic Michard; Ngai Liu; Andrea Kurz
Journal:  J Clin Monit Comput       Date:  2017-02-07       Impact factor: 2.502

Review 3.  Automated systems for perioperative goal-directed hemodynamic therapy.

Authors:  Sean Coeckelenbergh; Cedrick Zaouter; Brenton Alexander; Maxime Cannesson; Joseph Rinehart; Jacques Duranteau; Philippe Van der Linden; Alexandre Joosten
Journal:  J Anesth       Date:  2019-09-25       Impact factor: 2.078

4.  Feasibility of closed-loop titration of norepinephrine infusion in patients undergoing moderate- and high-risk surgery.

Authors:  Alexandre Joosten; Brenton Alexander; Jacques Duranteau; Fabio Silvio Taccone; Jacques Creteur; Jean-Louis Vincent; Maxime Cannesson; Joseph Rinehart
Journal:  Br J Anaesth       Date:  2019-06-27       Impact factor: 9.166

5.  Computer simulated modeling of healthy and diseased right ventricular and pulmonary circulation.

Authors:  Jody Chou; Joseph B Rinehart
Journal:  J Clin Monit Comput       Date:  2018-01-12       Impact factor: 2.502

6.  Computer-assisted Individualized Hemodynamic Management Reduces Intraoperative Hypotension in Intermediate- and High-risk Surgery: A Randomized Controlled Trial.

Authors:  Alexandre Joosten; Joseph Rinehart; Philippe Van der Linden; Brenton Alexander; Christophe Penna; Jacques De Montblanc; Maxime Cannesson; Jean-Louis Vincent; Eric Vicaut; Jacques Duranteau
Journal:  Anesthesiology       Date:  2021-08-01       Impact factor: 8.986

7.  Closed-loop regulation of arterial pressure after acute brain death.

Authors:  Kristian Soltesz; Trygve Sjöberg; Tomas Jansson; Rolf Johansson; Anders Robertsson; Audrius Paskevicius; Quiming Liao; Guangqi Qin; Stig Steen
Journal:  J Clin Monit Comput       Date:  2017-06-10       Impact factor: 2.502

Review 8.  Continuous Non-Invasive Arterial Pressure Assessment during Surgery to Improve Outcome.

Authors:  Alena Stenglova; Jan Benes
Journal:  Front Med (Lausanne)       Date:  2017-11-17

9.  Automated closed-loop versus manually controlled norepinephrine infusion in patients undergoing intermediate- to high-risk abdominal surgery: a randomised controlled trial.

Authors:  Alexandre Joosten; Dragos Chirnoaga; Philippe Van der Linden; Luc Barvais; Brenton Alexander; Jacques Duranteau; Jean-Louis Vincent; Maxime Cannesson; Joseph Rinehart
Journal:  Br J Anaesth       Date:  2020-10-08       Impact factor: 9.166

10.  Fully automated life support: an implementation and feasibility pilot study in healthy pigs.

Authors:  Wilfried Klingert; Jörg Peter; Christian Thiel; Karolin Thiel; Wolfgang Rosenstiel; Kathrin Klingert; Christian Grasshoff; Alfred Königsrainer; Martin Schenk
Journal:  Intensive Care Med Exp       Date:  2018-01-16
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.