Closed loop insulin delivery in diabetes.

Tadej Battelino1, Jasna Šuput Omladič2, Moshe Phillip3.   

Abstract

The primary goal of type 1 diabetes treatment is attaining near-normal glucose values. This currently remains out of reach for most people with type 1 diabetes despite intensified insulin treatment in the form of insulin analogues, educational interventions, continuous glucose monitoring, and sensor augmented insulin pump. The main remaining problem is risk of hypoglycaemia, which cannot be sufficiently reduced in all patient groups. Additionally, patients' burn-out often develops with years of tedious day-to-day diabetes management, rendering available diabetes-related technology less efficient. Over the past 40 years, several attempts have been made towards computer-programmed insulin delivery in the form of closed loop, with faster developments especially in the past decade. Automated insulin delivery has reduced human error in glycaemic control and considerably lessened the burden of routine self-management. In this chapter, data from randomized controlled trials with closed-loop insulin delivery that included type 1 diabetes population are summarized, and an evidence-based vision for possible routine utilization of closed loop is provided.
Copyright © 2015 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  artificial pancreas; closed loop insulin delivery; continuous glucose monitoring; glucose variability; glycaemic range; hypoglycaemia; mean blood glucose; sensor augmented insulin pump

Mesh:

Substances:

Year:  2015        PMID: 26051293     DOI: 10.1016/j.beem.2015.03.001

Source DB:  PubMed          Journal:  Best Pract Res Clin Endocrinol Metab        ISSN: 1521-690X            Impact factor:   4.690


  13 in total

1.  Feasibility of automated titration of vasopressor infusions using a novel closed-loop controller.

Authors:  Joseph Rinehart; Michael Ma; Michael-David Calderon; Maxime Cannesson
Journal:  J Clin Monit Comput       Date:  2017-01-25       Impact factor: 2.502

2.  Reducing glucose variability with continuous subcutaneous insulin infusion increases endothelial progenitor cells in type 1 diabetes: an observational study.

Authors:  Maria Ida Maiorino; Ofelia Casciano; Elisabetta Della Volpe; Giuseppe Bellastella; Dario Giugliano; Katherine Esposito
Journal:  Endocrine       Date:  2015-07-17       Impact factor: 3.633

3.  Hydrophobic Tags for Highly Efficient Light-Activated Protein Release.

Authors:  Karthik Nadendla; Bhagyesh R Sarode; Simon H Friedman
Journal:  Mol Pharm       Date:  2019-05-31       Impact factor: 4.939

4.  Exploring the Frequency Domain of Continuous Glucose Monitoring Signals to Improve Characterization of Glucose Variability and of Diabetic Profiles.

Authors:  Giuseppe Fico; Liss Hernández; Jorge Cancela; Miguel María Isabel; Andrea Facchinetti; Chiara Fabris; Rafael Gabriel; Claudio Cobelli; María Teresa Arredondo Waldmeyer
Journal:  J Diabetes Sci Technol       Date:  2017-01-09

Review 5.  Replacing Pumps with Light Controlled Insulin Delivery.

Authors:  Simon H Friedman
Journal:  Curr Diab Rep       Date:  2019-11-06       Impact factor: 4.810

Review 6.  Continuous Glucose Monitoring: A Review of Successes, Challenges, and Opportunities.

Authors:  David Rodbard
Journal:  Diabetes Technol Ther       Date:  2016-02       Impact factor: 6.118

7.  A New Optimized Percutaneous Access System for CIPII.

Authors:  Rosa Garcia-Verdugo; Michael Erbach; Oliver Schnell
Journal:  J Diabetes Sci Technol       Date:  2017-03-01

8.  Multinational Home Use of Closed-Loop Control Is Safe and Effective.

Authors:  Stacey M Anderson; Dan Raghinaru; Jordan E Pinsker; Federico Boscari; Eric Renard; Bruce A Buckingham; Revital Nimri; Francis J Doyle; Sue A Brown; Patrick Keith-Hynes; Marc D Breton; Daniel Chernavvsky; Wendy C Bevier; Paige K Bradley; Daniela Bruttomesso; Simone Del Favero; Roberta Calore; Claudio Cobelli; Angelo Avogaro; Anne Farret; Jerome Place; Trang T Ly; Satya Shanmugham; Moshe Phillip; Eyal Dassau; Isuru S Dasanayake; Craig Kollman; John W Lum; Roy W Beck; Boris Kovatchev
Journal:  Diabetes Care       Date:  2016-04-13       Impact factor: 19.112

Review 9.  Efficacy and Safety of Insulin Glargine 300 U/mL versus 100 U/mL in Diabetes Mellitus: A Comprehensive Review of the Literature.

Authors:  Hernando Vargas-Uricoechea
Journal:  J Diabetes Res       Date:  2018-02-12       Impact factor: 4.011

10.  Light Control of Insulin Release and Blood Glucose Using an Injectable Photoactivated Depot.

Authors:  Bhagyesh R Sarode; Karen Kover; Pei Y Tong; Chaoying Zhang; Simon H Friedman
Journal:  Mol Pharm       Date:  2016-10-15       Impact factor: 4.939

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.