Literature DB >> 2811764

Improved detectability in low signal-to-noise ratio magnetic resonance images by means of a phase-corrected real reconstruction.

M A Bernstein1, D M Thomasson, W H Perman.   

Abstract

We show that for magnetic resonance (MR) images with signal-to-noise ratio (SNR) less than 2 it is advantageous to use a phase-corrected real reconstruction, rather than the more usual magnitude reconstruction. We discuss the results of the phase correction algorithm used to experimentally verify the result. We supplement the existing literature by presenting closed form expressions (in an MR context) for the probability distribution and first moments of the signal resulting from a magnitude reconstruction.

Mesh:

Year:  1989        PMID: 2811764     DOI: 10.1118/1.596304

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  38 in total

1.  B₀ inhomogeneity-insensitive triple-quantum-filtered sodium imaging using a 12-step phase-cycling scheme.

Authors:  Lazar Fleysher; Niels Oesingmann; Matilde Inglese
Journal:  NMR Biomed       Date:  2010-12       Impact factor: 4.044

Review 2.  Errors in quantitative T1rho imaging and the correction methods.

Authors:  Weitian Chen
Journal:  Quant Imaging Med Surg       Date:  2015-08

3.  Phase-sensitive T1 inversion recovery imaging: a time-efficient interleaved technique for improved tissue contrast in neuroimaging.

Authors:  Ping Hou; Khader M Hasan; Clark W Sitton; Jerry S Wolinsky; Ponnada A Narayana
Journal:  AJNR Am J Neuroradiol       Date:  2005 Jun-Jul       Impact factor: 3.825

4.  A framework for accurate determination of the T₂ distribution from multiple echo magnitude MRI images.

Authors:  Ruiliang Bai; Cheng Guan Koay; Elizabeth Hutchinson; Peter J Basser
Journal:  J Magn Reson       Date:  2014-05-04       Impact factor: 2.229

5.  Referenceless acquisition of phase-sensitive inversion-recovery with decisive reconstruction (RAPID) imaging.

Authors:  Jinnan Wang; Huijun Chen; Jeffrey H Maki; Xihai Zhao; Gregory J Wilson; Chun Yuan; Peter Börnert
Journal:  Magn Reson Med       Date:  2013-11-11       Impact factor: 4.668

6.  Signal-to-noise measurements in magnitude images from NMR phased arrays.

Authors:  C D Constantinides; E Atalar; E R McVeigh
Journal:  Magn Reson Med       Date:  1997-11       Impact factor: 4.668

7.  3D flow-independent peripheral vessel wall imaging using T(2)-prepared phase-sensitive inversion-recovery steady-state free precession.

Authors:  Jingsi Xie; Xiaoming Bi; Zhaoyang Fan; Himanshu Bhat; Saurabh Shah; Sven Zuehlsdorff; Debiao Li
Journal:  J Magn Reson Imaging       Date:  2010-08       Impact factor: 4.813

8.  Incorporation of Rician noise in the analysis of biexponential transverse relaxation in cartilage using a multiple gradient echo sequence at 3 and 7 Tesla.

Authors:  Mustapha Bouhrara; David A Reiter; Hasan Celik; Jean-Marie Bonny; Vanessa Lukas; Kenneth W Fishbein; Richard G Spencer
Journal:  Magn Reson Med       Date:  2014-02-28       Impact factor: 4.668

9.  2D phase-sensitive inversion recovery imaging to measure in vivo spinal cord gray and white matter areas in clinically feasible acquisition times.

Authors:  Nico Papinutto; Regina Schlaeger; Valentina Panara; Eduardo Caverzasi; Sinyeob Ahn; Kevin J Johnson; Alyssa H Zhu; William A Stern; Gerhard Laub; Stephen L Hauser; Roland G Henry
Journal:  J Magn Reson Imaging       Date:  2014-12-08       Impact factor: 4.813

Review 10.  The role of tissue microstructure and water exchange in biophysical modelling of diffusion in white matter.

Authors:  Markus Nilsson; Danielle van Westen; Freddy Ståhlberg; Pia C Sundgren; Jimmy Lätt
Journal:  MAGMA       Date:  2013-02-27       Impact factor: 2.310