Literature DB >> 28111644

3D Ultrasonic Needle Tracking with a 1.5D Transducer Array for Guidance of Fetal Interventions.

Wenfeng Xia1, Simeon J West2, Jean-Martial Mari3, Sebastien Ourselin4, Anna L David5, Adrien E Desjardins1.   

Abstract

Ultrasound image guidance is widely used in minimally invasive procedures, including fetal surgery. In this context, maintaining visibility of medical devices is a significant challenge. Needles and catheters can readily deviate from the ultrasound imaging plane as they are inserted. When the medical device tips are not visible, they can damage critical structures, with potentially profound consequences including loss of pregnancy. In this study, we performed 3D ultrasonic tracking of a needle using a novel probe with a 1.5D array of transducer elements that was driven by a commercial ultrasound system. A fiber-optic hydrophone integrated into the needle received transmissions from the probe, and data from this sensor was processed to estimate the position of the hydrophone tip in the coordinate space of the probe. Golay coding was used to increase the signal-to-noise (SNR). The relative tracking accuracy was better than 0.4 mm in all dimensions, as evaluated using a water phantom. To obtain a preliminary indication of the clinical potential of 3D ultrasonic needle tracking, an intravascular needle insertion was performed in an in vivo pregnant sheep model. The SNR values ranged from 12 to 16 at depths of 20 to 31 mm and at an insertion angle of 49° relative to the probe surface normal. The results of this study demonstrate that 3D ultrasonic needle tracking with a fiber-optic hydrophone sensor and a 1.5D array is feasible in clinically realistic environments.

Entities:  

Mesh:

Year:  2016        PMID: 28111644      PMCID: PMC5245771          DOI: 10.1007/978-3-319-46720-7_41

Source DB:  PubMed          Journal:  Med Image Comput Comput Assist Interv


  15 in total

1.  Interference during the use of an electromagnetic tracking system under OR conditions.

Authors:  François Poulin; L-P Amiot
Journal:  J Biomech       Date:  2002-06       Impact factor: 2.712

Review 2.  Pregnancy loss after chorionic villus sampling and genetic amniocentesis in twin pregnancies: a systematic review.

Authors:  K Agarwal; Z Alfirevic
Journal:  Ultrasound Obstet Gynecol       Date:  2012-07-13       Impact factor: 7.299

3.  A non-disruptive technology for robust 3D tool tracking for ultrasound-guided interventions.

Authors:  Jay Mung; Francois Vignon; Ameet Jain
Journal:  Med Image Comput Comput Assist Interv       Date:  2011

4.  Piezoelectric vibrating needle and catheter for enhancing ultrasound-guided peripheral nerve blocks.

Authors:  Stephen M Klein; Matthew P Fronheiser; John Reach; Karen C Nielsen; Stephen W Smith
Journal:  Anesth Analg       Date:  2007-12       Impact factor: 5.108

5.  A Fabry-Perot fiber-optic ultrasonic hydrophone for the simultaneous measurement of temperature and acoustic pressure.

Authors:  Paul Morris; Andrew Hurrell; Adam Shaw; Edward Zhang; Paul Beard
Journal:  J Acoust Soc Am       Date:  2009-06       Impact factor: 1.840

6.  Vibrating interventional device detection using real-time 3-D color Doppler.

Authors:  Matthew P Fronheiser; Salim F Idriss; Patrick D Wolf; Stephen W Smith
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2008       Impact factor: 2.725

7.  Echogenic technology can improve needle visibility during ultrasound-guided regional anesthesia.

Authors:  Simon Hebard; Graham Hocking
Journal:  Reg Anesth Pain Med       Date:  2011 Mar-Apr       Impact factor: 6.288

8.  Acoustic Radiation Force Impulse (ARFI) imaging-based needle visualization.

Authors:  Veronica Rotemberg; Mark Palmeri; Stephen Rosenzweig; Stuart Grant; David Macleod; Kathryn Nightingale
Journal:  Ultrason Imaging       Date:  2011-01       Impact factor: 1.578

9.  Recombinant adeno-associated virus-mediated in utero gene transfer gives therapeutic transgene expression in the sheep.

Authors:  Anna L David; Jenny McIntosh; Donald M Peebles; Terry Cook; Simon Waddington; Boaz Weisz; Victoria Wigley; Khalil Abi-Nader; Michael Boyd; Andrew M Davidoff; Amit C Nathwani
Journal:  Hum Gene Ther       Date:  2011-02-02       Impact factor: 5.695

10.  Performance characteristics of an interventional multispectral photoacoustic imaging system for guiding minimally invasive procedures.

Authors:  Wenfeng Xia; Daniil I Nikitichev; Jean Martial Mari; Simeon J West; Rosalind Pratt; Anna L David; Sebastien Ourselin; Paul C Beard; Adrien E Desjardins
Journal:  J Biomed Opt       Date:  2015-08       Impact factor: 3.170

View more
  4 in total

1.  Ultrasonic Needle Tracking with a Fibre-Optic Ultrasound Transmitter for Guidance of Minimally Invasive Fetal Surgery.

Authors:  Wenfeng Xia; Sacha Noimark; Sebastien Ourselin; Simeon J West; Malcolm C Finlay; Anna L David; Adrien E Desjardins
Journal:  Med Image Comput Comput Assist Interv       Date:  2017-09-04

2.  Three-Dimensional Ultrasonic Needle Tip Tracking with a Fiber-Optic Ultrasound Receiver.

Authors:  Wenfeng Xia; Simeon J West; Malcolm C Finlay; Rosalind Pratt; Sunish Mathews; Jean-Martial Mari; Sebastien Ourselin; Anna L David; Adrien E Desjardins
Journal:  J Vis Exp       Date:  2018-08-21       Impact factor: 1.355

3.  Advanced ultrasound for prenatal interventions.

Authors:  Katika Nawapun; Nisarat Phithakwatchara; Suparat Jaingam; Sommai Viboonchart; Nadda Mongkolchat; Tuangsit Wataganara
Journal:  Ultrasonography       Date:  2018-05-02

4.  Enhanced Photoacoustic Visualisation of Clinical Needles by Combining Interstitial and Extracorporeal Illumination of Elastomeric Nanocomposite Coatings.

Authors:  Mengjie Shi; Semyon Bodian; Simeon J West; Sanjayan Sathasivam; Ross J Gordon; Paul Collier; Tom Vercauteren; Adrien E Desjardins; Sacha Noimark; Wenfeng Xia
Journal:  Sensors (Basel)       Date:  2022-08-25       Impact factor: 3.847

  4 in total