Literature DB >> 18042895

Piezoelectric vibrating needle and catheter for enhancing ultrasound-guided peripheral nerve blocks.

Stephen M Klein1, Matthew P Fronheiser, John Reach, Karen C Nielsen, Stephen W Smith.   

Abstract

Ultrasound imaging has been used for performing single-injection peripheral nerve blocks and continuous catheters. One limitation with current technology is the inability to confirm the location of the needle or catheter tip. We describe a new needle and catheter design that permits distal tip visualization using color flow Doppler. An 18-gauge 100-mm insulated Tuohy needle and a 20-gauge 50-mm polyamide catheter (open tip) with a Teflon-coated steel stylet (B. Braun, Bethlehem, PA) were customized by adhering in place two piezoelectric actuators. These created 1-8 kHz vibrations when coupled to a function generator (FG502, Tektronix, Richardson, TX) and a 100 W audio amplifier (R3000, KLH, Sun Valley, CA). Mimicking a lateral popliteal fossa block, the needle and catheter were inserted into the leg of an unembalmed cadaver. When activated, the tip of each was highlighted in color when scanned in the short axis using the color Doppler mode of a two-dimensional ultrasound and a 12 MHz L38 probe (MicroMaxx, Sonosite, Bothell, WA). Vibration technology may be a useful adjunct while performing ultrasound-guided regional anesthesia. Further study evaluating its usefulness and safety in live tissue is warranted.

Entities:  

Mesh:

Year:  2007        PMID: 18042895     DOI: 10.1213/01.ane.0000286814.79988.0a

Source DB:  PubMed          Journal:  Anesth Analg        ISSN: 0003-2999            Impact factor:   5.108


  13 in total

1.  Color Doppler imaging of cardiac catheters using vibrating motors.

Authors:  Kalyan E Reddy; Edward D Light; Danny J Rivera; Joseph A Kisslo; Stephen W Smith
Journal:  Ultrason Imaging       Date:  2008-10       Impact factor: 1.578

2.  Acoustic Radiation Force Impulse (ARFI) imaging-based needle visualization.

Authors:  Veronica Rotemberg; Mark Palmeri; Stephen Rosenzweig; Stuart Grant; David Macleod; Kathryn Nightingale
Journal:  Ultrason Imaging       Date:  2011-01       Impact factor: 1.578

Review 3.  Development of technologies for placement of perineural catheters.

Authors:  Hesham Elsharkawy; Ankit Maheshwari; Ehab Farag; Edward R Mariano; Richard W Rosenquist
Journal:  J Anesth       Date:  2015-09-14       Impact factor: 2.078

4.  Smart Blood Vessel Detection System for Laparoscopic Surgery.

Authors:  Ching-Chia Li; Bor-Shing Lin; Sheng-Chen Wen; Yuan-Teng Liang; Hung-Yu Sung; Jhen-Hao Jhan; Bor-Shyh Lin
Journal:  IEEE J Transl Eng Health Med       Date:  2022-03-11       Impact factor: 3.316

5.  Recent advance in patient monitoring.

Authors:  Tomoki Nishiyama
Journal:  Korean J Anesthesiol       Date:  2010-09-20

6.  3D Ultrasonic Needle Tracking with a 1.5D Transducer Array for Guidance of Fetal Interventions.

Authors:  Wenfeng Xia; Simeon J West; Jean-Martial Mari; Sebastien Ourselin; Anna L David; Adrien E Desjardins
Journal:  Med Image Comput Comput Assist Interv       Date:  2016-10

7.  In-plane ultrasonic needle tracking using a fiber-optic hydrophone.

Authors:  Wenfeng Xia; Jean Martial Mari; Simeon J West; Yuval Ginsberg; Anna L David; Sebastien Ourselin; Adrien E Desjardins
Journal:  Med Phys       Date:  2015-10       Impact factor: 4.071

8.  Photoacoustic Imaging for Image-guided Endovenous Laser Ablation Procedures.

Authors:  Yan Yan; Samuel John; Mahboobeh Ghalehnovi; Loay Kabbani; Nicole A Kennedy; Mohammad Mehrmohammadi
Journal:  Sci Rep       Date:  2019-02-27       Impact factor: 4.379

9.  Coded excitation ultrasonic needle tracking: An in vivo study.

Authors:  Wenfeng Xia; Yuval Ginsberg; Simeon J West; Daniil I Nikitichev; Sebastien Ourselin; Anna L David; Adrien E Desjardins
Journal:  Med Phys       Date:  2016-07       Impact factor: 4.071

10.  Accurate Needle Localization Using Two-Dimensional Power Doppler and B-Mode Ultrasound Image Analyses: A Feasibility Study.

Authors:  Mohammad I Daoud; Ahmad Shtaiyat; Adnan R Zayadeen; Rami Alazrai
Journal:  Sensors (Basel)       Date:  2018-10-16       Impact factor: 3.576

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.