Literature DB >> 30199033

Three-Dimensional Ultrasonic Needle Tip Tracking with a Fiber-Optic Ultrasound Receiver.

Wenfeng Xia1, Simeon J West2, Malcolm C Finlay3, Rosalind Pratt4, Sunish Mathews5, Jean-Martial Mari6, Sebastien Ourselin7, Anna L David8, Adrien E Desjardins5.   

Abstract

Ultrasound is frequently used for guiding minimally invasive procedures, but visualizing medical devices is often challenging with this imaging modality. When visualization is lost, the medical device can cause trauma to critical tissue structures. Here, a method to track the needle tip during ultrasound image-guided procedures is presented. This method involves the use of a fiber-optic ultrasound receiver that is affixed within the cannula of a medical needle to communicate ultrasonically with the external ultrasound probe. This custom probe comprises a central transducer element array and side element arrays. In addition to conventional two-dimensional (2D) B-mode ultrasound imaging provided by the central array, three-dimensional (3D) needle tip tracking is provided by the side arrays. For B-mode ultrasound imaging, a standard transmit-receive sequence with electronic beamforming is performed. For ultrasonic tracking, Golay-coded ultrasound transmissions from the 4 side arrays are received by the hydrophone sensor, and subsequently the received signals are decoded to identify the needle tip's spatial location with respect to the ultrasound imaging probe. As a preliminary validation of this method, insertions of the needle/hydrophone pair were performed in clinically realistic contexts. This novel ultrasound imaging/tracking method is compatible with current clinical workflow, and it provides reliable device tracking during in-plane and out-of-plane needle insertions.

Entities:  

Mesh:

Year:  2018        PMID: 30199033      PMCID: PMC6231697          DOI: 10.3791/57207

Source DB:  PubMed          Journal:  J Vis Exp        ISSN: 1940-087X            Impact factor:   1.355


  27 in total

1.  A non-disruptive technology for robust 3D tool tracking for ultrasound-guided interventions.

Authors:  Jay Mung; Francois Vignon; Ameet Jain
Journal:  Med Image Comput Comput Assist Interv       Date:  2011

Review 2.  Needle visualization in ultrasound-guided regional anesthesia: challenges and solutions.

Authors:  Ki Jinn Chin; Anahi Perlas; Vincent W S Chan; Richard Brull
Journal:  Reg Anesth Pain Med       Date:  2008 Nov-Dec       Impact factor: 6.288

3.  Photoacoustic needle: minimally invasive guidance to biopsy.

Authors:  Daniele Piras; Chiel Grijsen; Peter Schütte; Wiendelt Steenbergen; Srirang Manohar
Journal:  J Biomed Opt       Date:  2013-07       Impact factor: 3.170

Review 4.  Image-guided robotic interventions for prostate cancer.

Authors:  Ashwin N Sridhar; Archie Hughes-Hallett; Erik K Mayer; Philip J Pratt; Philip J Edwards; Guang-Zhong Yang; Ara W Darzi; Justin A Vale
Journal:  Nat Rev Urol       Date:  2013-06-18       Impact factor: 14.432

5.  Needle stylet with integrated optical fibers for spectroscopic contrast during peripheral nerve blocks.

Authors:  Adrien E Desjardins; Marjolein van der Voort; Stefan Roggeveen; Gerald Lucassen; Walter Bierhoff; Benno H W Hendriks; Marcus Brynolf; Björn Holmström
Journal:  J Biomed Opt       Date:  2011-07       Impact factor: 3.170

6.  Raman Spectroscopy Differentiates Each Tissue from the Skin to the Spinal Cord: A Novel Method for Epidural Needle Placement?

Authors:  T Anthony Anderson; Jeon Woong Kang; Tatyana Gubin; Ramachandra R Dasari; Peter T C So
Journal:  Anesthesiology       Date:  2016-10       Impact factor: 7.892

7.  In-plane ultrasonic needle tracking using a fiber-optic hydrophone.

Authors:  Wenfeng Xia; Jean Martial Mari; Simeon J West; Yuval Ginsberg; Anna L David; Sebastien Ourselin; Adrien E Desjardins
Journal:  Med Phys       Date:  2015-10       Impact factor: 4.071

8.  Coded excitation ultrasonic needle tracking: An in vivo study.

Authors:  Wenfeng Xia; Yuval Ginsberg; Simeon J West; Daniil I Nikitichev; Sebastien Ourselin; Anna L David; Adrien E Desjardins
Journal:  Med Phys       Date:  2016-07       Impact factor: 4.071

9.  Looking beyond the imaging plane: 3D needle tracking with a linear array ultrasound probe.

Authors:  Wenfeng Xia; Simeon J West; Malcolm C Finlay; Jean-Martial Mari; Sebastien Ourselin; Anna L David; Adrien E Desjardins
Journal:  Sci Rep       Date:  2017-06-16       Impact factor: 4.379

10.  Performance characteristics of an interventional multispectral photoacoustic imaging system for guiding minimally invasive procedures.

Authors:  Wenfeng Xia; Daniil I Nikitichev; Jean Martial Mari; Simeon J West; Rosalind Pratt; Anna L David; Sebastien Ourselin; Paul C Beard; Adrien E Desjardins
Journal:  J Biomed Opt       Date:  2015-08       Impact factor: 3.170

View more
  1 in total

Review 1.  Minimally invasive photoacoustic imaging: Current status and future perspectives.

Authors:  Tianrui Zhao; Adrien E Desjardins; Sebastien Ourselin; Tom Vercauteren; Wenfeng Xia
Journal:  Photoacoustics       Date:  2019-10-31
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.