Noriaki Murata1,2, Daiki Miyamoto1, Tetsuya Togano1, Takeo Fukuchi1.
Abstract
OBJECTIVE: To investigate the relationship between silent reading performance and visual field defects in patients with glaucoma using an eye tracking system.Entities:
Mesh:
Year: 2017 PMID: 28095478 PMCID: PMC5240996 DOI: 10.1371/journal.pone.0170230
Source DB: PubMed Journal: PLoS One ISSN: 1932-6203 Impact factor: 3.240
Fig 1Tobii Tx300 setup during the reading experiment.
Participants were evaluated during silent reading without a forehead and a chin rest in order to reproduce reading conditions in daily life. Participants were instructed not to lean forward in order to maintain the test distance. It is important to note that our reading experiment included the process of measuring either the point of gaze or the motion of an eye relative to the head. Therefore, we excluded data during saccades from the analysis of reading performance.
Fig 2A participant’s gaze pattern during the reading experiment.
The articles contain both Japanese syllabary (Hiragana) and Chinese characters (Kanji). A participant reads sentences in a horizontal direction from left to right. The size of the circle corresponds to the fixation duration. The number in the circle is the rank of fixation. The lines represent saccades.
Demographic characteristics and reading parameters in healthy controls and patients with glaucoma.
| Variables | Healthy controls ( | Patients with glaucoma ( | |
|---|---|---|---|
| Age, mean ± SD | 46.9 ± 17.2 | 52.2 ± 11.4 | 0.482 |
| Sex, male:female | 10:10 | 30:20 | 0.445 |
| RV, logMAR | -0.071 ± 0.024 | -0.079 ± 0.000 | 0.198 |
| LV, logMAR | -0.071 ± 0.024 | -0.079 ± 0.000 | 0.146 |
| RD (sec) | 8.8 ± 3.4 | 9.4 ± 3.3 | 0.543 |
| NF (times) | 32.7± 10.6 | 33.0 ± 10.7 | 0.925 |
| mFD (msec) | 215.7 ± 24.9 | 233.4 ± 25.1 | 0.010 |
Abbreviations: logMAR, logarithm of the minimum angle of resolution; LV, left visual acuity; mFD, mean fixation duration; NF, number of fixation per 100 characters; RD, reading duration per 100 characters; RV, right visual acuity; SD, standard deviation
* Mann-Whitney U-test
† Chi-square test
‡ Student’s t-test.
MD and VFI scores of patients with glaucoma.
| Eye | Index | Test | Mean ± SD | Range |
|---|---|---|---|---|
| Right | MD | 24–2 (dB) | -13.07 ± 8.46 | -1.36 – -29.00 |
| Left | MD | 24–2 (dB) | -13.03 ± 7.69 | -1.29 – -28.35 |
| Better | MD | 24–2 (dB) | -9.53 ± 7.34 | -1.29 – -25.73 |
| Worse | MD | 24–2 (dB) | -16.57 ± 7.18 | -4.89 – -29.00 |
| Right | VFI | 24–2 (%) | 62.76 ± 26.11 | 99.00 – 12.00 |
| Left | VFI | 24–2 (%) | 64.56 ± 23.77 | 100.00 – 10.00 |
| Better | VFI | 24–2 (%) | 73.68 ± 22.51 | 100.00 – 25.00 |
| Worse | VFI | 24–2 (%) | 53.64 ± 23.17 | 93.00 – 10.00 |
| Right | MD | 10–2 (dB) | -12.30 ± 8.78 | -0.67 – -30.39 |
| Left | MD | 10–2 (dB) | -11.06 ± 7.09 | -0.18 – -26.06 |
| Better | MD | 10–2 (dB) | -8.51 ± 7.12 | -0.18 – -25.85 |
| Worse | MD | 10–2 (dB) | -14.86 ± 7.54 | -1.60 – -30.39 |
Abbreviations: 10–2, 10–2 SITA standard field test; 24–2, 24–2 SITA standard field test; MD, mean deviation; VFI, visual field index.
Spearman’s rank correlation coefficients comparing reading parameters and visual field defects.
| ( | ( | ( | ( | |||||
| RD | 0.743 | (-0.047) | 0.054 | (-0.273) | 0.049* | (-0.280) | 0.958 | (-0.007) |
| NF | 0.635 | (0.069) | 0.204 | (-0.182) | 0.195 | (-0.186) | 0.525 | (0.092) |
| mFD | 0.241 | (-0.169) | 0.050 | (-0.279) | 0.150 | (-0.206) | 0.140 | (-0.212) |
| RD | 0.677 | (-0.060) | 0.032* | (-0.304) | 0.030* | (-0.306) | 0.768 | (-0.043) |
| NF | 0.709 | (0.054) | 0.114 | (-0.226) | 0.135 | (-0.214) | 0.734 | (0.049) |
| mFD | 0.215 | (-0.178) | 0.056 | (-0.272) | 0.084 | (-0.247) | 0.180 | (-0.193) |
| ( | ( | ( | ( | |||||
| RD | 0.432 | (-0.117) | 0.025* | (-0.326) | 0.032 | (-0.215) | 0.147 | (-0.220) |
| NF | 0.946 | (0.010) | 0.131 | (-0.224) | 0.503 | (-0.100) | 0.232 | (-0.182) |
| mFD | 0.072 | (-0.265) | 0.037* | (-0.306) | 0.104 | (-0.240) | 0.045* | (-0.294) |
Statistically significant associations are marked with asterisks.
Abbreviations: 10–2, 10–2 SITA standard field test; 24–2, 24–2 SITA standard field test; MD, mean deviation; mFD, mean fixation duration; NF, number of fixation per 100 characters; RD, reading duration per 100 characters; VFI, visual field index.