Géraldine Pastor1, María Jiménez-González2,3, Sandra Plaza-García2, Marta Beraza2, Torsten Reese2. 1. Molecular Imaging Unit, CIC biomaGUNE, Paseo Miramón 182, 20009, Donostia-San Sebastián, Spain. gpastor@cicbiomagune.es. 2. Molecular Imaging Unit, CIC biomaGUNE, Paseo Miramón 182, 20009, Donostia-San Sebastián, Spain. 3. Metabolism Division, Johns Hopkins University, CMSC Building 10-113, Baltimore, MD, 21287, USA.
Abstract
OBJECTIVE: A newly adapted zoomed ultrafast low-angle RARE (U-FLARE) sequence is described for abdominal imaging applications at 11.7 Tesla and compared with the standard echo-plannar imaging (EPI) and snapshot fast low angle shot (FLASH) methods. MATERIALS AND METHODS: Ultrafast EPI and snapshot-FLASH protocols were evaluated to determine relaxation times in phantoms and in the mouse kidney in vivo. Owing to their apparent shortcomings, imaging artefacts, signal-to-noise ratio (SNR), and variability in the determination of relaxation times, these methods are compared with the newly implemented zoomed U-FLARE sequence. RESULTS: Snapshot-FLASH has a lower SNR when compared with the zoomed U-FLARE sequence and EPI. The variability in the measurement of relaxation times is higher in the Look-Locker sequences than in inversion recovery experiments. Respectively, the average T1 and T2 values at 11.7 Tesla are as follows: kidney cortex, 1810 and 29 ms; kidney medulla, 2100 and 25 ms; subcutaneous tumour, 2365 and 28 ms. CONCLUSION: This study demonstrates that the zoomed U-FLARE sequence yields single-shot single-slice images with good anatomical resolution and high SNR at 11.7 Tesla. Thus, it offers a viable alternative to standard protocols for mapping very fast parameters, such as T1 and T2, or dynamic processes in vivo at high field.
OBJECTIVE: A newly adapted zoomed ultrafast low-angle RARE (U-FLARE) sequence is described for abdominal imaging applications at 11.7 Tesla and compared with the standard echo-plannar imaging (EPI) and snapshot fast low angle shot (FLASH) methods. MATERIALS AND METHODS: Ultrafast EPI and snapshot-FLASH protocols were evaluated to determine relaxation times in phantoms and in the mouse kidney in vivo. Owing to their apparent shortcomings, imaging artefacts, signal-to-noise ratio (SNR), and variability in the determination of relaxation times, these methods are compared with the newly implemented zoomed U-FLARE sequence. RESULTS: Snapshot-FLASH has a lower SNR when compared with the zoomed U-FLARE sequence and EPI. The variability in the measurement of relaxation times is higher in the Look-Locker sequences than in inversion recovery experiments. Respectively, the average T1 and T2 values at 11.7 Tesla are as follows: kidney cortex, 1810 and 29 ms; kidney medulla, 2100 and 25 ms; subcutaneous tumour, 2365 and 28 ms. CONCLUSION: This study demonstrates that the zoomed U-FLARE sequence yields single-shot single-slice images with good anatomical resolution and high SNR at 11.7 Tesla. Thus, it offers a viable alternative to standard protocols for mapping very fast parameters, such as T1 and T2, or dynamic processes in vivo at high field.
Entities:
Keywords:
Abdomen; High-field; Magnetic resonance imaging; Mice; Relaxation
Authors: Borjan A Gagoski; Berkin Bilgic; Cornelius Eichner; Himanshu Bhat; P Ellen Grant; Lawrence L Wald; Kawin Setsompop Journal: Magn Reson Med Date: 2015-02-02 Impact factor: 4.668
Authors: Yao Ding; Ralph P Mason; Roderick W McColl; Qing Yuan; Rami R Hallac; Robert D Sims; Paul T Weatherall Journal: J Magn Reson Imaging Date: 2013-06-07 Impact factor: 4.813
Authors: Dan Ma; Vikas Gulani; Nicole Seiberlich; Kecheng Liu; Jeffrey L Sunshine; Jeffrey L Duerk; Mark A Griswold Journal: Nature Date: 2013-03-14 Impact factor: 49.962