Literature DB >> 18243976

High-speed spiral-scan echo planar NMR imaging-I.

C B Ahn, J H Kim, Z H Cho.   

Abstract

An improved echo planar high-speed imaging technique using spiral scan is presented and experimental advantages are discussed. This proposed spiral-scan echo planar imaging (SEPI) technique employs two linearly increasing sinusoidal gradient fields, which results in a spiral trajectory in the spatial frequency domain (k-domain) that covers the entire frequency domain uniformly. The advantages of the method are: 1) circularly symmetric T2 weighting, resulting in a circularly symmetric point spread function in the image domain; 2) elimination of discontinuities in gradient waveforms which in turn will reduce initial transient as well as steady-state distortions; and 3) effective rapid spiral-scan from dc to high frequency in a continuous fashion, which ensures multiple pulsing with interlacing for further resolution improvement without T2 decay image degradation. Some preliminary experimental results will be presented and further possible improvements suggested.

Year:  1986        PMID: 18243976     DOI: 10.1109/TMI.1986.4307732

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  54 in total

Review 1.  Sources of distortion in functional MRI data.

Authors:  P Jezzard; S Clare
Journal:  Hum Brain Mapp       Date:  1999       Impact factor: 5.038

2.  Three-dimensional tailored RF pulses for the reduction of susceptibility artifacts in T(*)(2)-weighted functional MRI.

Authors:  V A Stenger; F E Boada; D C Noll
Journal:  Magn Reson Med       Date:  2000-10       Impact factor: 4.668

Review 3.  Real-time magnetic resonance imaging of cardiac function and flow-recent progress.

Authors:  Shuo Zhang; Arun A Joseph; Dirk Voit; Sebastian Schaetz; Klaus-Dietmar Merboldt; Christina Unterberg-Buchwald; Anja Hennemuth; Joachim Lotz; Jens Frahm
Journal:  Quant Imaging Med Surg       Date:  2014-10

4.  Multishot 3D slice-select tailored RF pulses for MRI.

Authors:  V Andrew Stenger; Fernando E Boada; Douglas C Noll
Journal:  Magn Reson Med       Date:  2002-07       Impact factor: 4.668

5.  2D-RF-pulse-encoded curved-slice imaging.

Authors:  Peter Börnert
Journal:  MAGMA       Date:  2003-07-08       Impact factor: 2.310

Review 6.  Spiral imaging in fMRI.

Authors:  Gary H Glover
Journal:  Neuroimage       Date:  2011-10-20       Impact factor: 6.556

7.  On spatially selective RF excitation and its analogy with spiral MR image acquisition.

Authors:  P Börnert; B Aldefeld
Journal:  MAGMA       Date:  1998-12       Impact factor: 2.310

8.  Improved radial GRAPPA calibration for real-time free-breathing cardiac imaging.

Authors:  Nicole Seiberlich; Philipp Ehses; Jeff Duerk; Robert Gilkeson; Mark Griswold
Journal:  Magn Reson Med       Date:  2010-09-24       Impact factor: 4.668

9.  Estimating Motion From MRI Data.

Authors:  Cengizhan Ozturk; J Andrew Derbyshire; Elliot R McVeigh
Journal:  Proc IEEE Inst Electr Electron Eng       Date:  2003-10       Impact factor: 10.961

10.  A Spiral Spin-Echo MR Imaging Technique for Improved Flow Artifact Suppression in T1-Weighted Postcontrast Brain Imaging: A Comparison with Cartesian Turbo Spin-Echo.

Authors:  Z Li; H H Hu; J H Miller; J P Karis; P Cornejo; D Wang; J G Pipe
Journal:  AJNR Am J Neuroradiol       Date:  2015-11-26       Impact factor: 3.825

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.