Analytical Modeling for Computing Lead Stress in a Novel Epicardial Micropacemaker.

Li Zhou1, Yaniv Bar-Cohen2, Raymond A Peck3, Giorgio V Chirikian3, Brett Harwin3, Ramen H Chmait4, Jay D Pruetz2,4, Michael J Silka2, Gerald E Loeb3.   

Abstract

Implantation and maintenance of a permanent cardiac pacing system in children remains challenging due to small patient size, congenital heart defects and somatic growth. We are developing a novel epicardial micropacemaker for children that can be implanted on the epicardium within the pericardial space via a minimally-invasive technique. The key design configurations include a novel open-coiled lead in which living tissue replaces the usual polymeric support for the coiled conductor. To better understand and be able to predict the behavior of the implanted lead, we performed a radiographic image-based modeling study on a chronic animal test. We report a pilot study in which two mechanical dummy pacemakers with epicardial leads were implanted into an adult pig model via a minimally invasive approach. Fluoroscopy was obtained on the animal on Post-Operative Days #9, #35 and #56 (necropsy). We then constructed an analytic model to estimate the in vivo stress conditions on the open-coil lead based on the analysis of orthogonal biplane radiographic images. We obtained geometric deformation data of the implanted lead including elongation magnitudes and bending radii from sequenced films of cardiac motion cycles. The lead stress distribution was investigated on each film frame and the point of maximum stress (Mean Stress = 531.4 MPa; Alternating Stress = ± 216.4 MPa) was consistently where one of the leads exited the pericardial space, a deployment that we expected to be unfavorable. These results suggest the modeling approach can provide a basis for further design optimization. More animal tests and modeling will be needed to validate whether the novel lead design could meet the requirements to withstand ~200 million cardiac motion cycles over 5 years.

Entities:  

Keywords:  Design optimization; Imaging analysis; Lead failure; Mechanical analysis; Pacemaker

Mesh:

Year:  2017        PMID: 28070867      PMCID: PMC5321717          DOI: 10.1007/s13239-017-0292-3

Source DB:  PubMed          Journal:  Cardiovasc Eng Technol        ISSN: 1869-408X            Impact factor:   2.495


  10 in total

Review 1.  Analysis of mammalian connective tissue: relationship between hierarchical structures and mechanical properties.

Authors:  F H Silver; Y P Kato; M Ohno; A J Wasserman
Journal:  J Long Term Eff Med Implants       Date:  1992

2.  FEA analysis of silicone MCP implant.

Authors:  E Podnos; E Becker; J Klawitter; P Strzepa
Journal:  J Biomech       Date:  2005-06-14       Impact factor: 2.712

3.  Long-term performance of polyurethane pacing leads: mechanisms of design-related failures.

Authors:  R Phillips; M Frey; R O Martin
Journal:  Pacing Clin Electrophysiol       Date:  1986-11       Impact factor: 1.976

4.  Stresses from flexure in composite helical implantable leads.

Authors:  J M Meagher; P Altman
Journal:  Med Eng Phys       Date:  1997-10       Impact factor: 2.242

Review 5.  Pacemaker leads: performance and progress.

Authors:  W G de Voogt
Journal:  Am J Cardiol       Date:  1999-03-11       Impact factor: 2.778

6.  Long-term performance of active-fixation pacing leads: a prospective study.

Authors:  Peter M Kistler; Gary Liew; Harry G Mond
Journal:  Pacing Clin Electrophysiol       Date:  2006-03       Impact factor: 1.976

7.  Patient, procedural, and hardware factors associated with pacemaker lead failures in pediatrics and congenital heart disease.

Authors:  Elizabeth B Fortescue; Charles I Berul; Frank Cecchin; Edward P Walsh; John K Triedman; Mark E Alexander
Journal:  Heart Rhythm       Date:  2004-07       Impact factor: 6.343

8.  Rotary bending fatigue of coils and wires used in cardiac lead design.

Authors:  P A Altman; J M Meagher; D W Walsh; D A Hoffmann
Journal:  J Biomed Mater Res       Date:  1998

Review 9.  Pacemakers and implantable cardioverter-defibrillators in pediatric patients.

Authors:  Michael J Silka; Yaniv Bar-Cohen
Journal:  Heart Rhythm       Date:  2006-02-28       Impact factor: 6.343

10.  Design and testing of a percutaneously implantable fetal pacemaker.

Authors:  Gerald E Loeb; Li Zhou; Kaihui Zheng; Adriana Nicholson; Raymond A Peck; Anjana Krishnan; Michael Silka; Jay Pruetz; Ramen Chmait; Yaniv Bar-Cohen
Journal:  Ann Biomed Eng       Date:  2012-08-02       Impact factor: 3.934

  10 in total
  3 in total

1.  Minimally Invasive Implantation of a Micropacemaker Into the Pericardial Space.

Authors:  Yaniv Bar-Cohen; Michael J Silka; Allison C Hill; Jay D Pruetz; Ramen H Chmait; Li Zhou; Sara M Rabin; Viktoria Norekyan; Gerald E Loeb
Journal:  Circ Arrhythm Electrophysiol       Date:  2018-07

Review 2.  Integrating mechanism-based modeling with biomedical imaging to build practical digital twins for clinical oncology.

Authors:  Chengyue Wu; Guillermo Lorenzo; David A Hormuth; Ernesto A B F Lima; Kalina P Slavkova; Julie C DiCarlo; John Virostko; Caleb M Phillips; Debra Patt; Caroline Chung; Thomas E Yankeelov
Journal:  Biophys Rev (Melville)       Date:  2022-05-17

Review 3.  Precision medicine in human heart modeling : Perspectives, challenges, and opportunities.

Authors:  M Peirlinck; F Sahli Costabal; J Yao; J M Guccione; S Tripathy; Y Wang; D Ozturk; P Segars; T M Morrison; S Levine; E Kuhl
Journal:  Biomech Model Mechanobiol       Date:  2021-02-12
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.