Literature DB >> 16606388

Long-term performance of active-fixation pacing leads: a prospective study.

Peter M Kistler1, Gary Liew, Harry G Mond.   

Abstract

BACKGROUND: Despite the increasingly widespread use of active-fixation leads, long-term clinical follow-up of pacing lead outcomes is lacking. The aim was to analyze pacing parameters over a 2-year follow-up. We performed a prospective observational study of consecutive new pacemaker implants using the 1488T St. Jude (100) and the Medtronic 5076 (100) active-fixation leads. Detailed analysis of pacing parameters was collected at implant, day 1, and 1, 3, 6, 12, 18, and 24 months. METHODS AND
RESULTS: One hundred patients underwent implantation of 100 dual-chamber pacemakers. Initial pacing parameters in the ventricle were threshold 0.7 +/- 0.2 V, R wave 12.0 +/- 6.5 mV, and impedance 879 +/- 224 Omega. Threshold increased significantly from day 1 (0.7 +/- 0.2 V) to month 1 (0.9 +/- 0.6 V, P < 0.01) and remained stable over the long term. Four of the 100 patients had a threshold >2 V (mean 3.3 +/- 0.9 V) all between day 1 and month 3. For all patients, R wave remained stable, but impedance declined significantly from day 1 (879 +/- 184 Omega) to month 1 (677 +/- 122 Omega, P < 0.01). There were no ventricular lead complications. Initial pacing parameters in the atrium were threshold 0.9 +/- 0.3 V, P wave 3.3 +/- 2.4 mV, and impedance 606 +/- 144 Omega. Threshold remained stable over the long-term follow-up. One of 100 patients had a rise in threshold >2 V (2.2 V) between day 1 and month 1. No patients underwent lead repositioning. Sensing and impedance remained stable over the long term. Patient follow-up was completed in 94% (6 unrelated deaths). There was an 8% incidence of atrial fibrillation.
CONCLUSION: Active-fixation leads are generally associated with stable long-term pacing parameters.

Entities:  

Mesh:

Year:  2006        PMID: 16606388     DOI: 10.1111/j.1540-8159.2006.00327.x

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  7 in total

1.  Analytical Modeling for Computing Lead Stress in a Novel Epicardial Micropacemaker.

Authors:  Li Zhou; Yaniv Bar-Cohen; Raymond A Peck; Giorgio V Chirikian; Brett Harwin; Ramen H Chmait; Jay D Pruetz; Michael J Silka; Gerald E Loeb
Journal:  Cardiovasc Eng Technol       Date:  2017-01-09       Impact factor: 2.495

2.  Right ventricular outflow tract septal pacing versus apical pacing: A prospective, randomized, single-blind 5-years follow-up study of ventricular lead performance and safety.

Authors:  Yuan-Hong Liang; Lie Liu; Dong-Li Chen; Chun-Ying Lin; Hong-Wen Fei; Si-Lin Chen; Shu-Lin Wu
Journal:  J Huazhong Univ Sci Technolog Med Sci       Date:  2015-12-16

3.  Combining current of injury and P-wave sensing optimized right atrial active-fixation leads implantation.

Authors:  Meng-Rong Chen; Fei-Long Zhang; Wei-Wei Wang; Xue-Hai Chen; Jian-Hua Chen; Liang-Long Chen
Journal:  J Thorac Dis       Date:  2019-04       Impact factor: 2.895

4.  Permanent pacemaker implanted into patient's left ventricle via subclavian artery by mistake: a case report.

Authors:  Guanmin Tang; Changlin Zhai; Zhiyong Wang; Hao Chen
Journal:  BMC Cardiovasc Disord       Date:  2015-05-12       Impact factor: 2.298

5.  A long-term, prospective, cohort study on the performance of right ventricular pacing leads: comparison of active-fixation with passive-fixation leads.

Authors:  Lie Liu; Jiaojiao Tang; Hu Peng; Shulin Wu; Chunying Lin; Dongli Chen; Qianhuan Zhang; Yuanhong Liang; Silin Chen; Yan Chen; Huiqiang Wei
Journal:  Sci Rep       Date:  2015-01-07       Impact factor: 4.379

6.  Long-term reliability of sweet-tip type screw-in leads.

Authors:  Asuka Takano; Gaku Sekita; Minako Watanabe; Hiroshi Mukaida; Sayaka Komatsu; Haruna Tabuchi; Hidemori Hayashi; Takashi Tokano; Masataka Sumiyoshi; Yuji Nakazato; Hiroyuki Daida
Journal:  J Arrhythm       Date:  2016-06-22

7.  Implantation of a dual-chamber pacemaker in a patient with dextrocardia and sick sinus syndrome: a case report.

Authors:  Junqian Luo; Zihao Zhou; Kaicong Chen; Junyao Lin; Chaogeng Cai; Zhihuan Zeng
Journal:  J Int Med Res       Date:  2022-03       Impact factor: 1.671

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.