Purpose. To obtain information about effect of cycloplegia on keratometry and biometry in keratoconus. Methods. 48 keratoconus (Group 1) and 52 healthy subjects (Group 2) were included in the study. We measured the flat meridian of the anterior corneal surface (K1), steep meridian of the anterior corneal surface (K2), lens thickness (LT), anterior chamber depth (ACD), and axial length (AL) using the Lenstar LS 900 before and after cycloplegia. Results. The median K1 in Group 1 was 45.64 D before and 45.42 D after cycloplegia, and the difference was statistically significant (P < 0.05). The median K2 in Group 1 was 50.96 D before and 50.17 D after cycloplegia, and the difference was significant (P < 0.05). The median K1 and K2 in Group 2 were 42.84 and 44.49 D, respectively, before cycloplegia, and 42.84 and 44.56 D after cycloplegia, and the differences were not statistically significant (all P > 0.05). There were significant differences in SE, LT, ACD, and RLP between before and after cycloplegia in either Group 1 (all P < 0.05) or Group 2 (all P < 0.05). There were not statistically significant differences in AL between before cycloplegia and after cycloplegia in either Group 1 (P = 0.533) or group 2 (P = 0.529). Conclusions. Flattened corneal curvature and increase in ACD following cycloplegia in keratoconus patients were detected.Entities:
Year: 2016 PMID: 28058115 PMCID: PMC5183766 DOI: 10.1155/2016/3437125
Source DB: PubMed Journal: J Ophthalmol ISSN: 2090-004X Impact factor: 1.909
Response to cycloplegia in Group 1 (n = 48).
| Before cycloplegia | After cycloplegia |
| |
|---|---|---|---|
| K1 (D) | 45.64 (42.06–57.74) | 45.42 (41.99–58.61) | 0.017 |
| K2 (D) | 50.96 (44.52–62.86) | 50.17 (44.39–64.41) | 0.001 |
| SE (D) | −4.05 (0.75–17.85) | −3.25 (0.65–14.85) | 0.0001 |
| LT (mm) | 3.45 (3.10–4.04) | 3.41 (3.01–3.94) | 0.0001 |
| ACD (mm) | 3.82 (3.44–4.22) | 3.95 (3.47–4.31) | 0.0001 |
| AL (mm) | 23.58 (21.91–25.55) | 23.56 (21.96–25.51) | 0.533 |
| RLP (mean ± SD) | 0.235 ± 0.01 | 0.238 ± 0.01 | 0.0001 |
K1: flat meridian of the anterior corneal surface, K2: steep meridian of the anterior corneal surface, SE: spherical equivalent, LT: lens thickness, ACD: anterior chamber depth, AL: axial length, RLP: relative lens position, D: diopter, and (−): negative value. Statisticaly significant.
Response to cycloplegia in Group 2 (n = 52).
| Before cycloplegia | After cycloplegia |
| |
|---|---|---|---|
| K1 (D) | 42.84 (38.87–47.03) | 42.84 (38.53–47.01) | 0.363 |
| K2 (D) | 44.49 (40.61–52.52) | 44.56 (40.14–52.61) | 0.660 |
| SE (D) | −1.5 (0.25–7.60) | −0.75 (0–7.50) | 0.0001 |
| LT (mm) | 3.48 (3.21–4.10) | 3.41 (3.12–4.02) | 0.0001 |
| ACD (mm) | 3.56 (2.80–4.39) | 3.69 (3.10–4.46) | 0.0001 |
| AL (mm) | 23.57 (22.05–27.30) | 23.58 (22.03–27.28) | 0.529 |
| RLP (mean ± SD) | 0.226 ± 0.01 | 0.230 ± 0.01 | 0.0001 |
K1: flat meridian of the anterior corneal surface, K2: steep meridian of the anterior corneal surface, SE: spherical equivalent, LT: lens thickness, ACD: anterior chamber depth, AL: axial length, RLP: relative lens position, D: diopter, and (−): negative value. Statisticaly significant.
Figure 1Keratometric changes with cycloplegia. K1: flat meridian of the anterior corneal surface, K2: steep meridian of the anterior corneal surface.
Figure 2LT and ACD changes with cycloplegia. LT: lens thickness, ACD: anterior chamber depth.
Figure 3RLP changes with cycloplegia. RLP: relative lens position.
Noncycloplegic situation between groups.
| Variables | Group 1 | Group 2 |
|
|---|---|---|---|
| K1 (D) | 45.64 (42.06–57.74) | 42.84 (38.87–47.03) | 0.0001 |
| K2 (D) | 50.96 (44.52–62.86) | 44.49 (40.61–52.52) | 0.0001 |
| SE (D) | 4.05 (0.75–17.85) | 1.5 (0.25–7.60) | 0.0001 |
| LT (mm) | 3.45 (3.10–4.04) | 3.48 (3.21–4.10) | 0.280 |
| ACD (mm) | 3.82 (3.44–4.22) | 3.56 (2.80–4.39) | 0.0001 |
| AL (mm) | 23.58 (21.91–25.55) | 23.57 (22.05–27.30) | 0.503 |
| RLP (mean ± SD) | 0.235 ± 0.01 | 0.226 ± 0.01 | 0.0001 |
K1: flat meridian of the anterior corneal surface, K2: steep meridian of the anterior corneal surface, SE: spherical equivalent, LT: lens thickness, ACD: anterior chamber depth, AL: axial length, RLP: relative lens position, and D: diopter. Statisticaly significant.
Cycloplegic situation between groups.
| Variables | Group 1 | Group 2 |
|
|---|---|---|---|
| K1 (D) | 45.42 (41.99–58.61) | 42.84 (38.53–47.01) | 0.0001 |
| K2 (D) | 50.17 (44.39–64.41) | 44.56 (40.14–52.61) | 0.0001 |
| SE (D) | 3.25 (0.65–14.85) | 0.75 (0–7.50) | 0.0001 |
| LT (mm) | 3.41 (3.01–3.94) | 3.41 (3.12–4.02) | 0.357 |
| ACD (mm) | 3.95 (3.47–4.31) | 3.69 (3.10–4.46) | 0.001 |
| AL (mm) | 23.56 (21.96–25.51) | 23.58 (22.03–27.28) | 0.506 |
| RLP (mean ± SD) | 0.238 ± 0.01 | 0.230 ± 0.01 | 0.0001 |
K1: flat meridian of the anterior corneal surface, K2: steep meridian of the anterior corneal surface, SE: spherical equivalent, LT: lens thickness, ACD: anterior chamber depth, AL: axial length, RLP: relative lens position, and D: diopter. Statisticaly significant.