PURPOSE: To compare the ciliary body morphology between the Caucasians and Chinese, and to determine the associated anterior segment parameters.
METHODS: The study groups were comprised of four age- and gender-matched cohorts: American Caucasians, American Chinese, southern and northern mainland Chinese. Ultrasound biomicroscopy (UBM) was performed to assess the following measurements of the ciliary body: trabecular-ciliary process distance (TCPD), trabecular-ciliary process angle (TCA) and ciliary body thickness at 1 mm posterior to the scleral spur (CBT1). A-scan ultrasonography was used to measure lens thickness (LT) and relative lens position (RLP), defined as (ACD + LT/2)/AL.
RESULTS: There were 109, 111, 115 and 117 subjects enrolled in the American Caucasian, American Chinese, and southern and northern mainland Chinese groups, respectively. Collectively, the Chinese had smaller TCPD (0.834 ± 0.234 versus 0.940 ± 0.236 mm, p < 0.001) and TCA (75.1 ± 17.9 versus 85.0 ± 21.5, p < 0.001) than Caucasians. No difference was found between the three Chinese subgroups, therefore they were combined as one for the following analyses. After multiple linear regression analysis, adjusting for age, gender, spherical equivalent (SE) and axial length (AL), TCPD and TCA were positively associated with CBT1 and RLP, but negatively correlated with LT in the whole sample. The ethnic Chinese had significantly smaller CBT1 (SRC = -0.177, p < 0.001) and RLP (SRC = -0.254, p < 0.001) than that of Caucasians.
CONCLUSIONS: Compared with the Caucasians, the Chinese had a thinner ciliary body and a more anteriorly positioned lens, which may contribute to more anteriorly positioned ciliary processes in this population. These findings might help to explain the higher prevalence of angle closure in the Chinese.

Entities:  

Keywords:  Biometry; ciliary body; ethnic difference; ultrasound biomicroscopy

Mesh:

Year:  2015        PMID: 25942335     DOI: 10.3109/02713683.2015.1024869

Source DB:  PubMed          Journal:  Curr Eye Res        ISSN: 0271-3683            Impact factor:   2.424


  13 in total

1.  Predictors of angle widening after laser iridotomy in Chinese patients with primary angle-closure suspect using ultrasound biomicroscopy.

Authors:  Xue-Ting Pei; Shu-Hua Wang; Xia Sun; Hong Chen; Bing-Song Wang; Shu-Ning Li; Tao Wang
Journal:  Int J Ophthalmol       Date:  2022-02-18       Impact factor: 1.779

2.  Ultrasound biomicroscopic imaging demonstrate thinner ciliary body thickness in eyes with angle closure.

Authors:  Shi-Yan Chen; Na He; Yu-Jie Yan; Xiang Fan; Ling-Ling Wu
Journal:  Int J Ophthalmol       Date:  2022-09-18       Impact factor: 1.645

3.  Characteristics of the Ciliary Body in Healthy Chinese Subjects Evaluated by Radial and Transverse Imaging of Ultrasound Biometric Microscopy.

Authors:  Jiawei Ren; Xinbo Gao; Liming Chen; Huishan Lin; Yao Liu; Yuying Zhou; Yunru Liao; Chunzi Xie; Chengguo Zuo; Mingkai Lin
Journal:  J Clin Med       Date:  2022-06-27       Impact factor: 4.964

4.  Morphological features of anterior segment: factors influencing intraocular pressure after cataract surgery in nanophthalmos.

Authors:  Qiang Lu; Wenwen He; Yi Lu; Xiangjia Zhu
Journal:  Eye Vis (Lond)       Date:  2020-09-09

5.  Does anisometropia affect the ciliary muscle thickness? An ultrasound biomicroscopy study.

Authors:  Selim Cevher; Tayfun Şahin
Journal:  Int Ophthalmol       Date:  2020-10-20       Impact factor: 2.031

6.  Effect of Cycloplegia on Keratometric and Biometric Parameters in Keratoconus.

Authors:  Nihat Polat; Abuzer Gunduz
Journal:  J Ophthalmol       Date:  2016-12-12       Impact factor: 1.909

7.  Difference of uveal parameters between the acute primary angle closure eyes and the fellow eyes.

Authors:  Xingyi Li; Wei Wang; Wenbin Huang; Shida Chen; Jiawei Wang; Zhonghao Wang; Yaoming Liu; Mingguang He; Xiulan Zhang
Journal:  Eye (Lond)       Date:  2018-03-01       Impact factor: 3.775

8.  Clinical 3D Imaging of the Anterior Segment With Ultrasound Biomicroscopy.

Authors:  Richard W Helms; Ahmed Tahseen Minhaz; David L Wilson; Faruk H Örge
Journal:  Transl Vis Sci Technol       Date:  2021-03-01       Impact factor: 3.283

9.  Comparison of uveal parameters between acute primary angle-closure eyes and fellow eyes in South Indian population.

Authors:  Vijayalakshmi A Senthilkumar; Chinmayee Pradhan; Sharmila Rajendrababu; R Krishnadas; Iswarya Mani
Journal:  Indian J Ophthalmol       Date:  2022-04       Impact factor: 2.969

10.  Spontaneous rotation of a toric implantable collamer lens related to abnormal ciliary body morphology: a case report.

Authors:  Qian Chen; Qingyan Zeng; Zheng Wang; Chao Pan; Xiaohua Lei; Weina Tan
Journal:  BMC Ophthalmol       Date:  2020-08-28       Impact factor: 2.209

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.