| Literature DB >> 26229805 |
Evandro Pereira Palácio1, André Araújo Ribeiro1, Bruno Moreira Gavassi1, Gabriel Guimarães Di Stasi1, José Antônio Galbiatti1, Alcides Durigam Junior1, Roberto Ryuiti Mizobuchi1.
Abstract
OBJECTIVE: the aim of this study was to assess the degree of exposure of the orthopedic surgical team to fluoroscopic ionizing radiation.Entities:
Keywords: Fluoroscopy; Ionizing radiation; Orthopedic surgery
Year: 2014 PMID: 26229805 PMCID: PMC4511650 DOI: 10.1016/j.rboe.2014.04.008
Source DB: PubMed Journal: Rev Bras Ortop ISSN: 2255-4971
Fig. 1Fluoroscope (lateral view).
Fig. 2Anterior and posterior locations of the dosimeters on the team members (above and below the lead protector).
Anatomical distribution of the dosimeters according to the team members.
| 1st surgeon (R2) | 2nd surgeon (R3) | Technologist (R1) | |
|---|---|---|---|
| Dorsal region (back) | Dosimeter 1 | Dosimeter 8 | Dosimeter 15 |
| Gonads (below the protector) | Dosimeter 2 | Dosimeter 9 | Dosimeter 16 |
| Gonads (above the protector) | Dosimeter 3 | Dosimeter 10 | Dosimeter 17 |
| Thyroid | Dosimeter 4 | Dosimeter 11 | Dosimeter 18 |
| Thorax (below the protector) | Dosimeter 5 | Dosimeter 12 | Dosimeter 19 |
| Thorax (above the protector) | Dosimeter 6 | Dosimeter 13 | Dosimeter 20 |
| Control | Dosimeter 7 | Dosimeter 14 | Dosimeter 21 |
Fig. 3Total radiation dose (mSv) received by the team members.
Fig. 4Total radiation dose (mSv) in the different anatomical areas of the team members.
Fig. 5Radiation dose (mSv) received in the thyroid region of the team members.
Fig. 6Radiation dose (mSv) received in the thoracic region of the team members.
Fig. 7Radiation dose (mSv) received in the gonadal region of the team members.
Fig. 8Reflected radiation (scattered radiation)