Literature DB >> 28004199

The effect of esophagogastroduodenoscopy probe insertion on the intracuff pressure of airway devices in children during general anesthesia.

Onur Balaban1, Mineto Kamata1, Mumin Hakim2, Dmitry Tumin1, Joseph D Tobias1,3.   

Abstract

Given the size of the esophagogastroduodenoscopy (EGD) probe and the compressibility of the pediatric airway, the EGD probe may increase the intracuff pressure (IP) of an airway device. The current study evaluated IP changes during EGD examination under general anesthesia in pediatric patients. Following the induction of anesthesia, a laryngeal mask airway (LMA) or endotracheal tube (ETT) was placed without neuromuscular blockade. The IP was measured at baseline, during EGD probe insertion, while the EGD probe was in place, and after probe removal. The study cohort included 101 patients (mean age 11.3 years). The airway was secured with an LMA and an ETT in 88 and 13 patients, respectively. The IP increased from 27 ± 15 cmH2O at baseline to 34 ± 17 cmH2O during probe insertion (p < 0.001), remained at 33 ± 16 cmH2O while the probe was in place, and decreased to 26 ± 14 cmH2O after probe removal. The IP of the LMA or ETT increased during EGD probe insertion and remained elevated while the probe was in place. High IP may compromise mucosal perfusion resulting in a sore throat when using an LMA or the potential for airway damage if an ETT is used. Removal of air from the cuff and titration of the IP should be considered after EGD insertion.

Entities:  

Keywords:  Esophagogastroduodenoscopy; Intracuff pressure; Probe insertion

Mesh:

Year:  2016        PMID: 28004199     DOI: 10.1007/s00540-016-2297-8

Source DB:  PubMed          Journal:  J Anesth        ISSN: 0913-8668            Impact factor:   2.078


  17 in total

1.  Using the inflating syringe as a safety valve to limit laryngeal mask airway cuff pressure.

Authors:  Mark J Rice; Nikolaus L Gravenstein; Sorin J Brull; Timothy E Morey; Nikolaus Gravenstein
Journal:  J Clin Monit Comput       Date:  2011-11-11       Impact factor: 2.502

2.  New insights into the mechanism of injury to the recurrent laryngeal nerve associated with the laryngeal mask airway.

Authors:  Junfeng Zhang; Zhe Zhao; Yongzhu Chen; Xiaoli Zhang
Journal:  Med Sci Monit       Date:  2010-05

3.  Reducing the incidence of sore throat with the laryngeal mask airway.

Authors:  M R Nott; P D Noble; M Parmar
Journal:  Eur J Anaesthesiol       Date:  1998-03       Impact factor: 4.330

4.  Fewer sore throats and a better seal: why routine manometry for laryngeal mask airways must become the standard of care.

Authors:  E Bick; I Bailes; A Patel; A I J Brain
Journal:  Anaesthesia       Date:  2014-10-10       Impact factor: 6.955

5.  A technique to measure the intracuff pressure continuously: an in vivo demonstration of its accuracy.

Authors:  Senthil G Krishna; Archana S Ramesh; Kris R Jatana; Charles Elmaraghy; Meredith Merz; James Ruda; Joseph D Tobias
Journal:  Paediatr Anaesth       Date:  2014-05-24       Impact factor: 2.556

6.  The laryngeal mask--a new concept in airway management.

Authors:  A I Brain
Journal:  Br J Anaesth       Date:  1983-08       Impact factor: 9.166

7.  An in vitro and in vivo validation of a novel color-coded syringe device for measuring the intracuff pressure in cuffed endotracheal tubes.

Authors:  Mineto Kamata; Hiromi Kako; Archana S Ramesh; Senthil G Krishna; Joseph D Tobias
Journal:  Int J Clin Exp Med       Date:  2015-07-15

8.  Pharyngolaryngeal, neck, and jaw discomfort after anesthesia with the face mask and laryngeal mask airway at high and low cuff volumes in males and females.

Authors:  J Brimacombe; L Holyoake; C Keller; N Brimacombe; M Scully; J Barry; P Talbutt; J Sartain; P McMahon
Journal:  Anesthesiology       Date:  2000-07       Impact factor: 7.892

9.  Clinical evaluation of a novel LMA with a color-coded pressure gauge.

Authors:  David P Martin; Tarun Bhalla; Arlyne Thung; Joseph D Tobias
Journal:  Int J Pediatr Otorhinolaryngol       Date:  2012-10-23       Impact factor: 1.675

10.  Laryngopharyngeal mucosal injury after prolonged use of the ProSeal LMA in a porcine model: a pilot study.

Authors:  Kai Goldmann; Joerg Dieterich; Marion Roessler
Journal:  Can J Anaesth       Date:  2007-10       Impact factor: 5.063

View more
  2 in total

1.  Clinical Outcomes of a Modified Laryngeal Mask Airway (LMA® Gastro™ Airway) During Esophagogastroduodenoscopy in Children and Adolescents: A Randomized Study.

Authors:  Mohammed Hakim; Jason Bryant; Renata Miketic; Kent Williams; Steven H Erdman; Shabana Z Shafy; Stephani S Kim; Joseph D Tobias
Journal:  Med Devices (Auckl)       Date:  2020-09-21

2.  Transesophageal probe placement increases endotracheal tube cuff pressure but is not associated with postoperative extubation failure after congenital cardiac surgery.

Authors:  Stephanie J Pan; Stephen Z Frabitore; Angela R Ingram; Khoa N Nguyen; Phillip S Adams
Journal:  Ann Card Anaesth       Date:  2020 Oct-Dec
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.