Accuracy of Breath-hold CT in Treatment Planning for Lung Stereotactic Ablative Radiotherapy.

Dominique Mathieu1, Charles Martel1, Marie-Pierre Campeau1, Édith Filion1, David Roberge2, Houda Bahig1, Toni Vu1, Louise Lambert1, Karim Boudam3, Jean-Francois Carrier1.   

Abstract

PURPOSE: The objectives of this study are (1) to measure concordance of tumor position on breath-hold (BH) computed tomography (CT) scans relative to the natural tumor path during free breathing (FB) and (2) to evaluate the benefits of the breathing monitoring device Abches (Apex Medical, Tokyo) for stereotactic ablative radiotherapy (SABR) treatment planning.
METHODS: In 53 lung cancer patients treated with CyberKnife™ robotic radiosurgery system, FB four-dimensional computerized tomography (4DCT) and end-expiration (EE) BH CT images were obtained. Extent of natural tumor motion was assessed with rigid registration derived from end-inspiration (EI) and EE phases of the 4DCT. Tumor displacement in BH scans relative to the natural tumor path was measured relative to the EE 4DCT phase.
RESULTS: Mean tumor motion (+/- 1 SD) during natural FB was 1 ± 1 mm, 2 ± 2 mm, and 6 ± 6 mm in medio-lateral, anterior-posterior, and cranio-caudal directions, respectively. Tumor position on BH CT scan was closer to EE than EI 4DCT phase for 35/53 patients (66%). Difference of BH tumor position vs. EE state was 4 ± 3 mm. Gross tumor displacements perpendicular to natural tumor path were as great as 11 mm (anterior-posterior) and were seen with or without the breathing monitoring device.
CONCLUSION: Tumor position during BH CT may not accurately correspond to positions observed on FB 4DCT. Hence, accurate and custom 4D analysis for each individual patient is recommended for treatment planning, especially those involving BH acquisitions.

Entities:  

Keywords:  4dct; abches; breath-hold; cyberknife™; sabr; treatment planning

Year:  2014        PMID: 28003937     DOI: 10.7759/cureus.236

Source DB:  PubMed          Journal:  Cureus        ISSN: 2168-8184


  12 in total

1.  Analysis of intrathoracic tumor mobility during whole breathing cycle by dynamic MRI.

Authors:  Christian Plathow; Sebastian Ley; Christian Fink; Michael Puderbach; Waldemar Hosch; Astrid Schmähl; Jürgen Debus; Hans-Ulrich Kauczor
Journal:  Int J Radiat Oncol Biol Phys       Date:  2004-07-15       Impact factor: 7.038

Review 2.  Real-time 4-D radiotherapy for lung cancer.

Authors:  Hiroki Shirato; Rikiya Onimaru; Masayori Ishikawa; Jun-ichi Kaneko; Tsuguhide Takeshima; Kenta Mochizuki; Shinichi Shimizu; Kikuo Umegaki
Journal:  Cancer Sci       Date:  2011-11-14       Impact factor: 6.716

3.  The management of tumor motions in the stereotactic irradiation to lung cancer under the use of Abches to control active breathing.

Authors:  Tohru I Tarohda; Mitsuru Ishiguro; Kouhei Hasegawa; Yukihiko Kohda; Hiroaki Onishi; Tetsuya Aoki; Tsuyoshi Takanaka
Journal:  Med Phys       Date:  2011-07       Impact factor: 4.071

4.  Predictive parameters of CyberKnife fiducial-less (XSight Lung) applicability for treatment of early non-small cell lung cancer: a single-center experience.

Authors:  Houda Bahig; Marie-Pierre Campeau; Toni Vu; Robert Doucet; Dominic Béliveau Nadeau; Bernard Fortin; David Roberge; Louise Lambert; Jean-François Carrier; Edith Filion
Journal:  Int J Radiat Oncol Biol Phys       Date:  2013-08-14       Impact factor: 7.038

5.  Reproducibility of diaphragm position assessed with a voluntary breath-holding device.

Authors:  Shigeyuki Takamatsu; Tsuyoshi Takanaka; Tomoyasu Kumano; Eiichi Mizuno; Satoshi Shibata; Shizuko Ohashi; Yuichi Kurata; Shinichi Ueda; Naoki Hori; Saori Shouji; Kimiya Noto; Hironori Kojima; Osamu Matsui
Journal:  Jpn J Radiol       Date:  2013-03-23       Impact factor: 2.374

6.  Precise and real-time measurement of 3D tumor motion in lung due to breathing and heartbeat, measured during radiotherapy.

Authors:  Yvette Seppenwoolde; Hiroki Shirato; Kei Kitamura; Shinichi Shimizu; Marcel van Herk; Joos V Lebesque; Kazuo Miyasaka
Journal:  Int J Radiat Oncol Biol Phys       Date:  2002-07-15       Impact factor: 7.038

7.  Assessing respiration-induced tumor motion and internal target volume using four-dimensional computed tomography for radiotherapy of lung cancer.

Authors:  H Helen Liu; Peter Balter; Teresa Tutt; Bum Choi; Joy Zhang; Catherine Wang; Melinda Chi; Dershan Luo; Tinsu Pan; Sandeep Hunjan; George Starkschall; Isaac Rosen; Karl Prado; Zhongxing Liao; Joe Chang; Ritsuko Komaki; James D Cox; Radhe Mohan; Lei Dong
Journal:  Int J Radiat Oncol Biol Phys       Date:  2007-03-29       Impact factor: 7.038

8.  4D-CT lung motion estimation with deformable registration: quantification of motion nonlinearity and hysteresis.

Authors:  Vlad Boldea; Gregory C Sharp; Steve B Jiang; David Sarrut
Journal:  Med Phys       Date:  2008-03       Impact factor: 4.071

9.  Dosimetric comparison of stereotactic body radiotherapy using 4D CT and multiphase CT images for treatment planning of lung cancer: evaluation of the impact on daily dose coverage.

Authors:  Lu Wang; Shelly Hayes; Kamen Paskalev; Lihui Jin; Mark K Buyyounouski; Charlie C-M Ma; Steve Feigenberg
Journal:  Radiother Oncol       Date:  2008-12-26       Impact factor: 6.280

10.  The deep inspiration breath hold technique using Abches reduces cardiac dose in patients undergoing left-sided breast irradiation.

Authors:  Ha Yoon Lee; Jee Suk Chang; Ik Jae Lee; Kwangwoo Park; Yong Bae Kim; Chang Ok Suh; Jun Won Kim; Ki Chang Keum
Journal:  Radiat Oncol J       Date:  2013-12-31
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.