Literature DB >> 27973351

Water equivalent path length calculations using scatter-corrected head and neck CBCT images to evaluate patients for adaptive proton therapy.

Jihun Kim, Yang-Kyun Park, Gregory Sharp, Paul Busse, Brian Winey.   

Abstract

Proton therapy has dosimetric advantages due to the well-defined range of the proton beam over photon radiotherapy. When the proton beams, however, are delivered to the patient in fractionated radiation treatment, the treatment outcome is affected by delivery uncertainties such as anatomic change in the patient and daily patient setup error. This study aims at establishing a method to evaluate the dosimetric impact of the anatomic change and patient setup error during head and neck proton therapy. Range variations due to the delivery uncertainties were assessed by calculating water equivalent path length (WEPL) to the distal edge of tumor volume using planning CT and weekly treatment cone-beam CT (CBCT) images. Specifically, mean difference and root mean squared deviation (RMSD) of the distal WEPLs were calculated as the weekly range variations. To accurately calculate the distal WEPLs, an existing CBCT scatter correction algorithm was used. An automatic rigid registration was used to align the planning CT and treatment CBCT images, simulating a six degree-of-freedom couch correction at treatments. The authors conclude that the dosimetric impact of the anatomic change and patient setup error was reasonably captured in the differences of the distal WEPL variation with a range calculation uncertainty of 2%. The proposed method to calculate the distal WEPL using the scatter-corrected CBCT images can be an essential tool to decide the necessity of re-planning in adaptive proton therapy.

Entities:  

Mesh:

Substances:

Year:  2016        PMID: 27973351      PMCID: PMC5397286          DOI: 10.1088/1361-6560/62/1/59

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  29 in total

1.  Multiple regions-of-interest analysis of setup uncertainties for head-and-neck cancer radiotherapy.

Authors:  Lifei Zhang; Adam S Garden; Justin Lo; K Kian Ang; Anesa Ahamad; William H Morrison; David I Rosenthal; Mark S Chambers; X Ronald Zhu; Radhe Mohan; Lei Dong
Journal:  Int J Radiat Oncol Biol Phys       Date:  2006-04-01       Impact factor: 7.038

2.  Assessment of parotid gland dose changes during head and neck cancer radiotherapy using daily megavoltage computed tomography and deformable image registration.

Authors:  Choonik Lee; Katja M Langen; Weiguo Lu; Jason Haimerl; Eric Schnarr; Kenneth J Ruchala; Gustavo H Olivera; Sanford L Meeks; Patrick A Kupelian; Thomas D Shellenberger; Rafael R Mañon
Journal:  Int J Radiat Oncol Biol Phys       Date:  2008-06-04       Impact factor: 7.038

3.  Investigating CT to CBCT image registration for head and neck proton therapy as a tool for daily dose recalculation.

Authors:  Guillaume Landry; Reinoud Nijhuis; George Dedes; Josefine Handrack; Christian Thieke; Guillaume Janssens; Jonathan Orban de Xivry; Michael Reiner; Florian Kamp; Jan J Wilkens; Chiara Paganelli; Marco Riboldi; Guido Baroni; Ute Ganswindt; Claus Belka; Katia Parodi
Journal:  Med Phys       Date:  2015-03       Impact factor: 4.071

4.  Quantitative cone-beam CT imaging in radiation therapy using planning CT as a prior: first patient studies.

Authors:  Tianye Niu; Ahmad Al-Basheer; Lei Zhu
Journal:  Med Phys       Date:  2012-04       Impact factor: 4.071

5.  Investigating deformable image registration and scatter correction for CBCT-based dose calculation in adaptive IMPT.

Authors:  Christopher Kurz; Florian Kamp; Yang-Kyun Park; Christoph Zöllner; Simon Rit; David Hansen; Mark Podesta; Gregory C Sharp; Minglun Li; Michael Reiner; Jan Hofmaier; Sebastian Neppl; Christian Thieke; Reinoud Nijhuis; Ute Ganswindt; Claus Belka; Brian A Winey; Katia Parodi; Guillaume Landry
Journal:  Med Phys       Date:  2016-10       Impact factor: 4.071

6.  The impact of daily setup variations on head-and-neck intensity-modulated radiation therapy.

Authors:  Theodore S Hong; Wolfgang A Tomé; Richard J Chappell; Prakash Chinnaiyan; Minesh P Mehta; Paul M Harari
Journal:  Int J Radiat Oncol Biol Phys       Date:  2005-03-01       Impact factor: 7.038

7.  Calibration of CT Hounsfield units for proton therapy treatment planning: use of kilovoltage and megavoltage images and comparison of parameterized methods.

Authors:  L De Marzi; C Lesven; R Ferrand; J Sage; T Boulé; A Mazal
Journal:  Phys Med Biol       Date:  2013-05-29       Impact factor: 3.609

8.  Quantification of volumetric and geometric changes occurring during fractionated radiotherapy for head-and-neck cancer using an integrated CT/linear accelerator system.

Authors:  Jerry L Barker; Adam S Garden; K Kian Ang; Jennifer C O'Daniel; He Wang; Laurence E Court; William H Morrison; David I Rosenthal; K S Clifford Chao; Susan L Tucker; Radhe Mohan; Lei Dong
Journal:  Int J Radiat Oncol Biol Phys       Date:  2004-07-15       Impact factor: 7.038

9.  Spot-scanning beam proton therapy vs intensity-modulated radiation therapy for ipsilateral head and neck malignancies: a treatment planning comparison.

Authors:  Shravan Kandula; Xiaorong Zhu; Adam S Garden; Michael Gillin; David I Rosenthal; Kie-Kian Ang; Radhe Mohan; Mayankkumar V Amin; John A Garcia; Richard Wu; Narayan Sahoo; Steven J Frank
Journal:  Med Dosim       Date:  2013-08-02       Impact factor: 1.482

10.  Quantitative assessment of anatomical change using a virtual proton depth radiograph for adaptive head and neck proton therapy.

Authors:  Peng Wang; Lingshu Yin; Yawei Zhang; Maura Kirk; Gang Song; Peter H Ahn; Alexander Lin; James Gee; Derek Dolney; Timothy D Solberg; Richard Maughan; James McDonough; Boon-Keng Kevin Teo
Journal:  J Appl Clin Med Phys       Date:  2016-03-08       Impact factor: 2.102

View more
  9 in total

1.  A robotic C-arm cone beam CT system for image-guided proton therapy: design and performance.

Authors:  Chiaho Hua; Weiguang Yao; Takao Kidani; Kazuo Tomida; Saori Ozawa; Takenori Nishimura; Tatsuya Fujisawa; Ryousuke Shinagawa; Thomas E Merchant
Journal:  Br J Radiol       Date:  2017-10-09       Impact factor: 3.039

2.  Beam angle optimization using angular dependency of range variation assessed via water equivalent path length (WEPL) calculation for head and neck proton therapy.

Authors:  Jihun Kim; Yang-Kyun Park; Gregory Sharp; Paul Busse; Brian Winey
Journal:  Phys Med       Date:  2019-12-05       Impact factor: 2.685

Review 3.  Adaptive proton therapy.

Authors:  Harald Paganetti; Pablo Botas; Gregory C Sharp; Brian Winey
Journal:  Phys Med Biol       Date:  2021-11-15       Impact factor: 3.609

4.  Evaluation of CBCT scatter correction using deep convolutional neural networks for head and neck adaptive proton therapy.

Authors:  Arthur Lalonde; Brian Winey; Joost Verburg; Harald Paganetti; Gregory C Sharp
Journal:  Phys Med Biol       Date:  2020-12-04       Impact factor: 3.609

5.  Commissioning an in-room mobile CT for adaptive proton therapy with a compact proton system.

Authors:  Jasmine A Oliver; Omar Zeidan; Sanford L Meeks; Amish P Shah; Jason Pukala; Patrick Kelly; Naren R Ramakrishna; Twyla R Willoughby
Journal:  J Appl Clin Med Phys       Date:  2018-04-06       Impact factor: 2.102

6.  Potential proton and photon dose degradation in advanced head and neck cancer patients by intratherapy changes.

Authors:  Kristin Stützer; Annika Jakobi; Anna Bandurska-Luque; Steffen Barczyk; Carolin Arnsmeyer; Steffen Löck; Christian Richter
Journal:  J Appl Clin Med Phys       Date:  2017-09-18       Impact factor: 2.102

7.  Evaluation of an a priori scatter correction algorithm for cone-beam computed tomography based range and dose calculations in proton therapy.

Authors:  Andreas Gravgaard Andersen; Yang-Kyun Park; Ulrik Vindelev Elstrøm; Jørgen Breede Baltzer Petersen; Gregory C Sharp; Brian Winey; Lei Dong; Ludvig Paul Muren
Journal:  Phys Imaging Radiat Oncol       Date:  2020-10-27

8.  CBCT-Based Adaptive Assessment Workflow for Intensity Modulated Proton Therapy for Head and Neck Cancer.

Authors:  Mariluz De Ornelas; Yihang Xu; Kyle Padgett; Ryder M Schmidt; Michael Butkus; Tejan Diwanji; Gus Luciani; Jason Lambiase; Stuart Samuels; Michael Samuels; Nesrin Dogan
Journal:  Int J Part Ther       Date:  2021-03-15

9.  CT-on-Rails Versus In-Room CBCT for Online Daily Adaptive Proton Therapy of Head-and-Neck Cancers.

Authors:  Konrad P Nesteruk; Mislav Bobić; Arthur Lalonde; Brian A Winey; Antony J Lomax; Harald Paganetti
Journal:  Cancers (Basel)       Date:  2021-11-28       Impact factor: 6.639

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.