Literature DB >> 27957093

Atrial Fibrillation Radiofrequency Ablation: Safety Using Contact Force Catheter In A Low-Volume Centre.

Diego Vaccari Md1, Daniele Giacopelli MSc2, Eros Rocchetto MSc2, Sabina Vittadello Md1, Roberto Mantovan Md3, Gianfilippo Neri Md1.   

Abstract

The tip-to-tissue contact force (CF) has been identified as a potential determinant of lesion quality during radiofrequency (RF) ablation. The aim of this paper is to report the experience of a single low-volume centre in the atrial fibrillation (AF) ablation procedure with an RF catheter capable of measuring this parameter. CF data and their possible implications on patient safety are presented. Thirty-nine consecutive patients suffering of paroxysmal or permanent AF received percutaneous ablation with the novel catheter studied. Procedural characteristics, CF applied and safety events related to the procedure were reported. During RF application the mean CF value was 17 ± 3 g, with a maximum mean value of 37 ± 8 g. CF value never exceeded 62 g and in the 74% of the RF applications ranged between 10 g and 30 g. No complication related to the catheter manipulation or to the energy delivered was observed. This study of a single centre with a low level of experience in AF ablation suggests that the ability to measure CF may provide additional useful information to the operator. It ensures uniform ablations, with little variability in the catheter manipulations, and it avoids excessive contact forces increasing the patient safety.

Entities:  

Keywords:  Atrial Fibrillation; Catheter Ablation; Contact Force; Force-To-Time Integral; Radiofrequency; Safe Ablation

Year:  2014        PMID: 27957093      PMCID: PMC5135250          DOI: 10.4022/jafib.1043

Source DB:  PubMed          Journal:  J Atr Fibrillation        ISSN: 1941-6911


  16 in total

1.  Area under the real-time contact force curve (force-time integral) predicts radiofrequency lesion size in an in vitro contractile model.

Authors:  Dipen C Shah; Hendrik Lambert; Hiroshi Nakagawa; Arne Langenkamp; Nicolas Aeby; Giovanni Leo
Journal:  J Cardiovasc Electrophysiol       Date:  2010-09

2.  Venice Chart international consensus document on atrial fibrillation ablation.

Authors:  Andrea Natale; Antonio Raviele; Thomas Arentz; Hugh Calkins; Shih-Ann Chen; Michel Haïssaguerre; Gerhard Hindricks; Yen Ho; Karl Heinz Kuck; Francis Marchlinski; Carlo Napolitano; Douglas Packer; Carlo Pappone; Eric N Prystowsky; Richard Schilling; Dipen Shah; Sakis Themistoclakis; Atul Verma
Journal:  J Cardiovasc Electrophysiol       Date:  2007-05

Review 3.  Complications during catheter ablation of atrial fibrillation: identification and prevention.

Authors:  Harish Doppalapudi; Takumi Yamada; G Neal Kay
Journal:  Heart Rhythm       Date:  2009-10-23       Impact factor: 6.343

4.  Electrical reconnection after pulmonary vein isolation is contingent on contact force during initial treatment: results from the EFFICAS I study.

Authors:  Petr Neuzil; Vivek Y Reddy; Josef Kautzner; Jan Petru; Dan Wichterle; Dipen Shah; Hendrik Lambert; Aude Yulzari; Erik Wissner; Karl-Heinz Kuck
Journal:  Circ Arrhythm Electrophysiol       Date:  2013-03-20

5.  Updated worldwide survey on the methods, efficacy, and safety of catheter ablation for human atrial fibrillation.

Authors:  Riccardo Cappato; Hugh Calkins; Shih-Ann Chen; Wyn Davies; Yoshito Iesaka; Jonathan Kalman; You-Ho Kim; George Klein; Andrea Natale; Douglas Packer; Allan Skanes; Federico Ambrogi; Elia Biganzoli
Journal:  Circ Arrhythm Electrophysiol       Date:  2009-12-07

6.  The relationship between contact force and clinical outcome during radiofrequency catheter ablation of atrial fibrillation in the TOCCATA study.

Authors:  Vivek Y Reddy; Dipen Shah; Josef Kautzner; Boris Schmidt; Nadir Saoudi; Claudia Herrera; Pierre Jaïs; Gerhard Hindricks; Petr Peichl; Aude Yulzari; Hendrik Lambert; Petr Neuzil; Andrea Natale; Karl-Heinz Kuck
Journal:  Heart Rhythm       Date:  2012-07-20       Impact factor: 6.343

Review 7.  Stability of complex fractionated atrial electrograms: a systematic review.

Authors:  Dennis H Lau; Bart Maesen; Stef Zeemering; Sander Verheule; Harry J Crijns; Ulrich Schotten
Journal:  J Cardiovasc Electrophysiol       Date:  2012-05-03

8.  Comparison between anatomical and integrated approaches to atrial fibrillation ablation: adjunctive role of electrical pulmonary vein disconnection.

Authors:  Roberto Mantovan; Roberto Verlato; Vittorio Calzolari; Stella Baccillieri; Alessandro De Leo; Pietro Turrini; Giovanni Pastore; Martino Crosato; Angelo Ramondo; Paolo Stritoni
Journal:  J Cardiovasc Electrophysiol       Date:  2005-12

9.  Importance of catheter contact force during irrigated radiofrequency ablation: evaluation in a porcine ex vivo model using a force-sensing catheter.

Authors:  Aravinda Thiagalingam; Andre D'Avila; Lori Foley; J Luis Guerrero; Hendrik Lambert; Giovanni Leo; Jeremy N Ruskin; Vivek Y Reddy
Journal:  J Cardiovasc Electrophysiol       Date:  2010-02-01

10.  Steam pops during irrigated radiofrequency ablation: feasibility of impedance monitoring for prevention.

Authors:  Jens Seiler; Kurt C Roberts-Thomson; Jean-Marc Raymond; John Vest; Etienne Delacretaz; William G Stevenson
Journal:  Heart Rhythm       Date:  2008-07-10       Impact factor: 6.343

View more
  2 in total

1.  Lesion modeling, characterization, and visualization for image-guided cardiac ablation therapy monitoring.

Authors:  Cristian A Linte; Jon J Camp; Maryam E Rettmann; Dieter Haemmerich; Mehmet K Aktas; David T Huang; Douglas L Packer; David R Holmes
Journal:  J Med Imaging (Bellingham)       Date:  2018-03-01

2.  A comparison of 8-mm and open-irrigated gold-tip catheters for typical atrial flutter ablation: Data from a prospective multicenter registry.

Authors:  Ermenegildo De Ruvo; Antonio Sagone; Giovanni Rovaris; Procolo Marchese; Matteo Santamaria; Francesco Solimene; Werner Rauhe; Elena Piazzi; Luciano Moretti; Quintino Parisi; Vincenzo Schillaci; Elisa Pelissero; Massimiliano Manfrin; Daniele Giacopelli; Alessio Gargaro; Leonardo Calò; Gaetano Senatore
Journal:  J Arrhythm       Date:  2018-06-13
  2 in total