Literature DB >> 27873022

Current rare indications and future directions for implantable loop recorders.

Simon Wechselberger1, Christopher Piorkowski2,3, Matthias Pohl1,4.   

Abstract

The scope of application for implantable loop recorders has shifted away from the evaluation of unclear palpitations and syncope episodes to more complex conditions. This article focuses on rare indications of growing importance such as rhythm monitoring after ablation of atrial fibrillation or after cryptogenic stroke. Furthermore, forthcoming applications in various clinical settings are described, e. g., arrhythmia detection after myocardial infarction, after catheter-based valve interventions, in heart failure, and in cardiomyopathies. Enhancement of the capabilities of implantable loop recorders could broaden their fields of use.

Entities:  

Keywords:  Atrial fibrillation; Electrocardiography monitoring, ambulatory; Implantable loop recorder; Stroke; Syncope

Mesh:

Year:  2016        PMID: 27873022     DOI: 10.1007/s00399-016-0475-x

Source DB:  PubMed          Journal:  Herzschrittmacherther Elektrophysiol        ISSN: 0938-7412


  47 in total

Review 1.  New devices in heart failure: an European Heart Rhythm Association report: developed by the European Heart Rhythm Association; endorsed by the Heart Failure Association.

Authors:  Karl-Heinz Kuck; Pierre Bordachar; Martin Borggrefe; Giuseppe Boriani; Haran Burri; Francisco Leyva; Patrick Schauerte; Dominic Theuns; Bernard Thibault; Paulus Kirchhof; Gerhard Hasenfuss; Kenneth Dickstein; Christophe Leclercq; Cecilia Linde; Luigi Tavazzi; Frank Ruschitzka
Journal:  Europace       Date:  2013-11-20       Impact factor: 5.214

Review 2.  Open issues in transcatheter aortic valve implantation. Part 2: procedural issues and outcomes after transcatheter aortic valve implantation.

Authors:  Jeroen J Bax; Victoria Delgado; Vinayak Bapat; Helmut Baumgartner; Jean P Collet; Raimund Erbel; Christian Hamm; Arie P Kappetein; Jonathon Leipsic; Martin B Leon; Philip MacCarthy; Nicolo Piazza; Philippe Pibarot; William C Roberts; Josep Rodés-Cabau; Patrick W Serruys; Martyn Thomas; Alec Vahanian; John Webb; Jose Luis Zamorano; Stephan Windecker
Journal:  Eur Heart J       Date:  2014-07-25       Impact factor: 29.983

Review 3.  The Reveal LINQ insertable cardiac monitor.

Authors:  Todd T Tomson; Rod Passman
Journal:  Expert Rev Med Devices       Date:  2014-08-26       Impact factor: 3.166

4.  Atrial fibrillation in patients with cryptogenic stroke.

Authors:  David J Gladstone; Melanie Spring; Paul Dorian; Val Panzov; Kevin E Thorpe; Judith Hall; Haris Vaid; Martin O'Donnell; Andreas Laupacis; Robert Côté; Mukul Sharma; John A Blakely; Ashfaq Shuaib; Vladimir Hachinski; Shelagh B Coutts; Demetrios J Sahlas; Phil Teal; Samuel Yip; J David Spence; Brian Buck; Steve Verreault; Leanne K Casaubon; Andrew Penn; Daniel Selchen; Albert Jin; David Howse; Manu Mehdiratta; Karl Boyle; Richard Aviv; Moira K Kapral; Muhammad Mamdani
Journal:  N Engl J Med       Date:  2014-06-26       Impact factor: 91.245

5.  Recurrent unexplained palpitations (RUP) study comparison of implantable loop recorder versus conventional diagnostic strategy.

Authors:  Franco Giada; Michele Gulizia; Maura Francese; Francesco Croci; Lucio Santangelo; Maurizio Santomauro; Eraldo Occhetta; Carlo Menozzi; Antonio Raviele
Journal:  J Am Coll Cardiol       Date:  2007-04-30       Impact factor: 24.094

Review 6.  Predictors of permanent pacemaker implantation in patients with severe aortic stenosis undergoing TAVR: a meta-analysis.

Authors:  George C M Siontis; Peter Jüni; Thomas Pilgrim; Stefan Stortecky; Lutz Büllesfeld; Bernhard Meier; Peter Wenaweser; Stephan Windecker
Journal:  J Am Coll Cardiol       Date:  2014-07-15       Impact factor: 24.094

Review 7.  Noninvasive cardiac monitoring for detecting paroxysmal atrial fibrillation or flutter after acute ischemic stroke: a systematic review.

Authors:  Joy Liao; Zahira Khalid; Ciaran Scallan; Carlos Morillo; Martin O'Donnell
Journal:  Stroke       Date:  2007-09-27       Impact factor: 7.914

8.  Low rate of atrial fibrillation recurrence verified by implantable loop recorder monitoring following a convergent epicardial and endocardial ablation of atrial fibrillation.

Authors:  Borut Gersak; Andrej Pernat; Boris Robic; Matjaz Sinkovec
Journal:  J Cardiovasc Electrophysiol       Date:  2012-05-15

9.  Specific cardiological evaluation after focal cerebral ischemia.

Authors:  C R Hornig; W Haberbosch; C Lammers; B Waldecker; W Dorndorf
Journal:  Acta Neurol Scand       Date:  1996-04       Impact factor: 3.209

10.  Cost implications of testing strategy in patients with syncope: randomized assessment of syncope trial.

Authors:  Andrew D Krahn; George J Klein; Raymond Yee; Jeffrey S Hoch; Allan C Skanes
Journal:  J Am Coll Cardiol       Date:  2003-08-06       Impact factor: 24.094

View more
  4 in total

1.  Clinical evaluation of a small implantable cardiac monitor with a long sensing vector.

Authors:  Christopher Piorkowski; Mathias Busch; Georg Nölker; Jörn Schmitt; Franz Xaver Roithinger; Glenn Young; Miloš Táborský; Gundula Herrmann; Dietmar Schmitz
Journal:  Pacing Clin Electrophysiol       Date:  2019-06-05       Impact factor: 1.976

2.  Analysis of the determining factors of detectable P-wave and amplitude of QRS complex sensed by implantable loop recorder.

Authors:  Jang Ho Ahn; Hyunho Ryu; Il-Young Oh; Youngjin Cho; Ji Hyun Lee
Journal:  J Arrhythm       Date:  2021-06-24

3.  New-generation miniaturized insertable cardiac monitor with a long sensing vector: Insertion procedure, sensing performance, and home monitoring transmission success in a real-world population.

Authors:  Thomas Deneke; Pilar Cabanas; Daniel Hofer; Thomas Gaspar; Bertrand Pierre; Giovanni Bisignani; Rajeev Kumar Pathak; Victor Manuel Sanfins; Eimo Martens; Jacques Mansourati; Antonio Berruezo-Sanchez; Marcus Wiemer; Andreas Hain; Thomas Pezawas; Beate Wenzel; Dennis Lau
Journal:  Heart Rhythm O2       Date:  2022-01-30

4.  The BIOMONITOR III Injectable Cardiac Monitor: Clinical Experience with a Novel Injectable Cardiac Monitor.

Authors:  Nico Reinsch; Anna Füting; Dennis Höwel; Kars Neven
Journal:  J Clin Med       Date:  2022-03-16       Impact factor: 4.241

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.