Literature DB >> 17498580

Recurrent unexplained palpitations (RUP) study comparison of implantable loop recorder versus conventional diagnostic strategy.

Franco Giada1, Michele Gulizia, Maura Francese, Francesco Croci, Lucio Santangelo, Maurizio Santomauro, Eraldo Occhetta, Carlo Menozzi, Antonio Raviele.   

Abstract

OBJECTIVES: The aim of the study was to compare the diagnostic yield and the costs of implantable loop recorder (ILR) with those of the conventional strategy in patients with unexplained palpitations.
BACKGROUND: In patients with unexplained palpitations, especially in those with infrequent symptoms, the conventional strategy, including short-term ambulatory electrocardiogram (ECG) monitoring and electrophysiological study, sometimes fails to establish a diagnosis.
METHODS: We studied 50 patients with infrequent (< or =1 episode/month), sustained (>1 min) palpitations. Before enrollment, patients had a negative initial evaluation, including history, physical examination, and ECG. Patients were randomized either to conventional strategy (24-h Holter recording, a 4-week period of ambulatory ECG monitoring with an external recorder, and electrophysiological study) (n = 24) or to ILR implantation with 1-year monitoring (n = 26). Hospital costs of the 2 strategies were calculated.
RESULTS: A diagnosis was obtained in 5 patients in the conventional strategy group, and in 19 subjects in the ILR group (21% vs. 73%, p < 0.001). Despite the higher initial cost, the cost per diagnosis in the ILR group was lower than in the conventional strategy group (euro 3,056 +/- euro 363 vs. euro 6,768 +/- euro 6,672, p = 0.012).
CONCLUSIONS: In subjects without severe heart disease and with infrequent palpitations, ILR is a safe and more cost-effective diagnostic approach than conventional strategy.

Entities:  

Mesh:

Year:  2007        PMID: 17498580     DOI: 10.1016/j.jacc.2007.02.036

Source DB:  PubMed          Journal:  J Am Coll Cardiol        ISSN: 0735-1097            Impact factor:   24.094


  30 in total

1.  The Evaluation of the Patient with Unexplained Palpitations: Maximizing Diagnostic Yield while Minimizing Unnecessary Frustration.

Authors:  Suneet Mittal
Journal:  Ann Noninvasive Electrocardiol       Date:  2015-11-02       Impact factor: 1.468

Review 2.  Current rare indications and future directions for implantable loop recorders.

Authors:  Simon Wechselberger; Christopher Piorkowski; Matthias Pohl
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2016-12

Review 3.  Recommendations on the use of innovative medical technologies in cardiology and cardiac surgery and solutions leading to increased availability for Polish patients.

Authors:  Dariusz Dudek; Waldemar Banasiak; Wojciech Braksator; Jacek Dubiel; Tomasz Grodzicki; Piotr Hoffman; Mariusz Kuśmierczyk; Grzegorz Opolski; Piotr Ponikowski; Jacek Różański; Jerzy Sadowski; Wojciech Wojakowski; Marcin Grabowski; Katarzyna Bondaryk; Jacek Walczak; Izabela Pieniążek; Maciej Grys; Anna Lesiak-Bednarek; Piotr Przygodzki
Journal:  Cardiol J       Date:  2019-02-14       Impact factor: 2.737

Review 4.  The Role of Implantable Cardiac Monitors in Atrial Fibrillation Management.

Authors:  Giuseppe Ciconte; Daniele Giacopelli; Carlo Pappone
Journal:  J Atr Fibrillation       Date:  2017-08-31

5.  Usefulness of an implantable loop recorder in patients with syncope of an unknown cause.

Authors:  Gu Hyun Kang; Ju Hyeon Oh; Woo Jung Chun; Yong Hwan Park; Bong Gun Song; June Soo Kim; Young Keun On; Seung Jung Park; June Huh
Journal:  Yonsei Med J       Date:  2013-05-01       Impact factor: 2.759

6.  The diagnostic yield of implantable loop recorders stratified by indication: "real-world" use in a large academic hospital.

Authors:  Alexander Smith; Makenzie Perdue; Jetmir Vojnika; Daniel R Frisch; Behzad B Pavri
Journal:  J Interv Card Electrophysiol       Date:  2020-07-04       Impact factor: 1.900

7.  Efficacy And Safety Of Implantable Loop Recorder: Experience Of A Center.

Authors:  Inês Silveira; Maria João Sousa; Nuno Antunes; Vânia Silva; Carla Roque; António Pinheiro-Vieira; Vítor Lagarto; António Hipólito-Reis; André Luz; Severo Torres
Journal:  J Atr Fibrillation       Date:  2016-08-31

Review 8.  [Event-recorder].

Authors:  Andreas Schuchert
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2008-10-25

9.  A media player causes clinically significant telemetry interference with implantable loop recorders.

Authors:  Jay P Thaker; Mehul B Patel; Ashok J Shah; Valdis V Liepa; Krit Jongnarangsin; Ranjan K Thakur
Journal:  J Interv Card Electrophysiol       Date:  2009-01-16       Impact factor: 1.900

10.  Gender differences in onset of symptoms in AV nodal re-entrant and accessory pathway-mediated re-entrant tachycardia.

Authors:  T Deneke; P Müller; T Lawo; B Lemke; M Horlitz; B Calcum; L-I Bösche; A Mügge; P H Grewe
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2009-04-18