Literature DB >> 27840451

Capacitance-Based Dosimetry of Co-60 Radiation using Fully-Depleted Silicon-on-Insulator Devices.

Yulong Li1, Warren M Porter2, Rui Ma1, Margaret A Reynolds3, Bruce J Gerbi3, Steven J Koester1.   

Abstract

The capacitance based sensing of fully-depleted silicon-on-insulator (FDSOI) variable capacitors for Co-60 gamma radiation is investigated. Linear response of the capacitance is observed for radiation dose up to 64 Gy, while the percent capacitance change per unit dose is as high as 0.24 %/Gy. An analytical model is developed to study the operational principles of the varactors and the maximum sensitivity as a function of frequency is determined. The results show that FDSOI varactor dosimeters have potential for extremely-high sensitivity as well as the potential for high frequency operation in applications such as wireless radiation sensing.

Entities:  

Year:  2015        PMID: 27840451      PMCID: PMC5102626          DOI: 10.1109/TNS.2015.2487239

Source DB:  PubMed          Journal:  IEEE Trans Nucl Sci        ISSN: 0018-9499            Impact factor:   1.679


  6 in total

1.  A 2-D diode array and analysis software for verification of intensity modulated radiation therapy delivery.

Authors:  Paul A Jursinic; Ben E Nelms
Journal:  Med Phys       Date:  2003-05       Impact factor: 4.071

2.  Evidence that similar point defects cause 1/f noise and radiation-induced-hole trapping in metal-oxide-semiconductor transistors.

Authors: 
Journal:  Phys Rev Lett       Date:  1990-01-29       Impact factor: 9.161

3.  Clinical dosimetry using MOSFETs.

Authors:  R Ramani; S Russell; P O'Brien
Journal:  Int J Radiat Oncol Biol Phys       Date:  1997-03-01       Impact factor: 7.038

4.  Direct dose confirmation of quantitative autoradiography with micro-TLD measurements for radioimmunotherapy.

Authors:  M H Griffith; E D Yorke; B W Wessels; G L DeNardo; W P Neacy
Journal:  J Nucl Med       Date:  1988-11       Impact factor: 10.057

5.  An implantable radiation dosimeter for use in external beam radiation therapy.

Authors:  Charles W Scarantino; David M Ruslander; Christopher J Rini; Gregory G Mann; H Troy Nagle; Robert D Black
Journal:  Med Phys       Date:  2004-09       Impact factor: 4.071

6.  Characterization of optically stimulated luminescent dosimeters, OSLDs, for clinical dosimetric measurements.

Authors:  Paul A Jursinic
Journal:  Med Phys       Date:  2007-12       Impact factor: 4.071

  6 in total
  1 in total

1.  Feasibility study on a novel tiny dosimeter using a barium titanate capacitor.

Authors:  Yuma Kuga; Ryo Ogawara; Masayori Ishikawa
Journal:  J Radiat Res       Date:  2020-01-23       Impact factor: 2.724

  1 in total